USC and USC-LCE Operations 99
4
System powers off and perform iDRAC configuration and firmware
restore. After completion, iDRAC resets and takes up to 10 minutes before
the system powers on.
5
System powers on and restore process is complete. Check the Lifecycle
logs for the restore process entries.
See Also
Import Server Profile
Importing Server Profile after Motherboard
Replacement
Prerequisites
• A backup of the server with the old motherboard.
• If you are restoring from a the Dell vFlash SD card, it must be installed
and must contain the backup image in a folder labeled SRVCNF. This
image must be from the same platform that you are trying to restore.
• If you are restoring from a network share, make sure that the network share
where the backup image file is stored is still accessible.
Workflow
After replacing the motherboard, follow the steps under
vFlash SD Card
,
Network Share
, or
USB Device
to restore the system information.
Post-requisites
• See Post-import Scenario
• The Service tag is restored from the backup file on the new motherboard.