USC and USC-LCE Operations 39
For NFS
•
Share Name
— Type the path to the shared folder where you must
store the file. For example,
\\xxx.xxx.xx.xx\sharename
.
•File Location
— Type the sub-directories if any. For example,
2010\Apr
.
4
Click
Test Network Connection
to verify if USC-LCE is able to connect to
the IP address that you provided. By default, it pings the Gateway and
DNS server IP.
5
Click
Finish
to export the inventory.
See Also:
• About View and Export Current Inventory
• About View and Export Factory Shipped Inventory
Viewing and Exporting Hardware Inventory after
Resetting Lifecycle Controller
NOTE: After performing Delete Configuration and Reset Defaults, the system shuts
down.
To view or export the hardware inventory data after resetting the Lifecycle
Controller:
1
Power on the system and wait for a couple of minutes for iDRAC to start
functioning.
2
Since
Collect System Inventory on Restart
(
CSIOR
) is not enabled after
reset, press <F10> to launch USC so that the system inventory is
collected. After USC launches, exit the wizard and wait for the system to
reboot.
3
Disconnect the power cord and wait for 30 seconds. Reconnect the power
cord and boot the system to USC.