USC and USC-LCE Operations 93
Supported Devices
You can update the part firmware and configuration for the following devices:
NOTE: Only part firmware updates are supported on SAS cards and power supply
units.
•NICs (Broadcom)
• PERC, SAS, and CERC series 6 and 7
•Power Supply Units
Collect System Inventory on Restart
When you enable the Collect System Inventory On Restart property,
hardware inventory and part configuration information is discovered and
compared with previous system inventory information on every system
restart. To do this:
1
In the left pane, click
Platform Restore
.
2
Click
Part Replacement Configuration
.
3
Click either
Enabled
or
Disabled
from the
Collect System Inventory on
Restart
drop-down.
Part Firmware Update
From the part firmware update drop-down, select one of the following:
•
Disabled
— Firmware update on replaced parts is not performed.
•
Allow version upgrade only
— Firmware update on replaced parts is only
performed if the firmware version of the new part is lower than the existing
part.
•
Match firmware of replaced part
— Firmware on the new part is updated
to the version of the original part.