Storage Management Message Reference 99
2107 SMART
configuration
change
Critical /
Failure / Error
Cause: A disk has
received a SMART alert
(predictive failure) after
a configuration change.
The disk is likely to fail
in the near future.
Action: Replace the
disk that has received
the SMART alert. If the
physical disk is a
member of a non-
redundant virtual disk,
then back up the data
before replacing the
disk.
CAUTION:
Removing a physical
disk that is included in a
non-redundant virtual
disk causes the virtual
disk to fail and may
cause data loss.
Clear Alert
Number:
None
Related
Alert
Number:
None
LRA
Number:
2071
904
Table 3-4. Storage Management Messages
(continued)