Storage Management Message Reference 205
2340 The BGI com-
pleted with
uncorrectable
errors.
Critical /
Failure / Error
Cause: The BGI task
encountered errors that
cannot be corrected.
The virtual disk
contains physical disks
that have unusable disk
space or disk errors that
cannot be corrected.
Action: Replace the
physical disk that
contains the disk errors.
Review other alert
messages to identify the
physical disk that has
errors. If the virtual disk
is redundant, you can
replace the physical disk
and continue using the
virtual disk. If the virtual
disk is non-redundant,
you may need to recreate
the virtual disk after
replacing the physical
disk. After replacing the
physical disk, run Check
Consistency to check
the data.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2081
1204
2341 The Check
Consistency
made
corrections and
completed.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
1201
Table 3-4. Storage Management Messages
(continued)