Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Guia do Utilizador Página 210

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 292
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 209
210 Storage Management Message Reference
2348 The rebuild
failed due to
errors on the
target physical
disk.
Critical /
Failure / Error
Cause: Yo u a r e
attempting to rebuild
data on a disk that is
defective.
Action: Replace the
target disk. If a rebuild
does not automatically
start after replacing the
disk, initiate the
Rebuild task. You may
need to assign the new
disk as a hot spare to
initiate the rebuild.
Clear Alert:
None
Related
Alert
Number:
2195, 2346
LRA
Number:
2071
904
2349 A bad disk
block could
not be
reassigned
during a write
operation.
Critical /
Failure / Error
Cause: A write
operation could not
complete because the
disk contains bad disk
blocks that could not be
reassigned. Data loss
may have occurred and
data redundancy may
also be lost.
Action: Replace the
disk.
Clear Alert:
None
Related
Alert
Number:
2346
LRA
Number:
2071
904
2350 There was an
unrecoverable
disk media
error during
the rebuild or
recovery
operation.
Critical /
Failure / Error
Cause: The rebuild or
recovery operation
encountered an
unrecoverable disk
media error.
Action: Replace the
disk.
Clear Alert:
None
Related
Alert
Number:
2095, 2273
LRA
Number:
2071
904
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Vista de página 209
1 2 ... 205 206 207 208 209 210 211 212 213 214 215 ... 291 292

Comentários a estes Manuais

Sem comentários