144 Storage Management Message Reference
2190 The controller
has detected a
hot-add of an
enclosure.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
751
2191 Multiple
enclosures are
attached to the
controller. This
is an
unsupported
configuration.
Critical /
Failure / Error
Cause: There are too
many enclosures
attached to the
controller port. When
the enclosure limit is
exceeded, the controller
loses contact with all
enclosures attached to
the port.
Action: Remove the last
enclosure. You must
remove the enclosure
that has been added last
and is causing the
enclosure limit to
exceed.
Clear Alert:
None
Related
Alert
Number:
2211
LRA
Number:
2091
854
Table 3-4. Storage Management Messages
(continued)