Storage Management Message Reference 107
2118 Change write
policy
OK / Normal /
Informational
Cause: Auser has
changed the write
policy for a virtual disk.
This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None
Related
Alert
Number:
None
LRA
Number:
None
1201
2120 Enclosure
firmware
mismatch
Warning /
Non-critical
Cause: The firmware on
the EMM is not the
same version. It is
required that both
modules have the same
version of the firmware.
This alert may be
caused when a user
attempts to insert an
EMM module that has
a different firmware
version than an existing
module.
Action: Download the
same version of the
firmware to both EMM
modules.
Clear Alert
Number:
None
Related
Alert
Number:
None
LRA
Number:
2090
853
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Vista de página 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 291 292

Comentários a estes Manuais

Sem comentários