150 Storage Management Message Reference
2205 A dedicated
hot spare has
been
automatically
unassigned.
OK / Normal /
Informational
Cause: The hot spare is
no longer required
because the virtual disk
it was assigned to has
been deleted.
Action: None
Clear Alert:
None
Related
Alert
Number:
2098, 2161,
2196
LRA
Number:
None
901
2206 The only hot
spare available
is a SATA disk.
SATA disks
cannot replace
SAS disks.
Warning /
Non-critical
Cause: The only
physical disk available
to be assigned as a hot
spare is using SATA
technology. The
physical disks in the
virtual disk are using
SAS technology.
Because of this
difference in
technology, the hot
spare cannot rebuild
data if one of the
physical disks in the
virtual disk fails.
Action: Add a SAS disk
that is large enough to
be used as the hot spare
and assign it as a hot
spare.
Clear Alert:
None
Related
Alert
Number:
None
LRA
Number:
2070
903
Table 3-4. Storage Management Messages