Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Guia do Utilizador Página 224

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 292
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 223
224 Storage Management Message Reference
2384 The Warning
level set for the
hot spare
protection
policy is
violated for the
Virtual Disk.
Warning /
Non-critical
Cause: The number of
physical disks you
specified for the hot
spare protection policy
is violated.
Action: Reassign the
number of hot spares as
specified in the
protection policy for
that RAID level.
Clear Alert:
2195
Related
Alert: None
LRA
Number:
None
1203
2385 The Critical
level set for the
hot spare
protection
policy is
violated for the
Virtual Disk.
Critical /
Failure / Error
Cause: The number of
physical disks you
specified for the hot
spare protection policy
is violated.
Action: Reassign the
number of hot spares as
specified in the
protection policy for
that RAID level.
Clear Alert:
2195
Related
Alert: None
LRA
Number:
None
1204
2386 The drive
could not be
assigned as a
Dedicated Hot
Spare.
Warning /
Non-critical
Cause: The assignment
of a Dedicated Hot
Spare fails as the disk is
invalid.
Action: None
Clear Alert:
2195
Related
Alert: None
LRA
Number:
None
901
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Vista de página 223
1 2 ... 219 220 221 222 223 224 225 226 227 228 229 ... 291 292

Comentários a estes Manuais

Sem comentários