Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Guia do Utilizador Página 82

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 292
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 81
82 Storage Management Message Reference
2075 Copy of data
completed
from physical
disk %2 to
physical disk
%1.
OK / Normal /
Informational
Cause: This alert is
provided for
informational purposes.
Action: None
Clear Alert
Number:
None
Related
Alert
Number:
2060
LRA
Number:
None
1201
2076 Virtual disk
Check
Consistency
failed
Critical /
Failure / Error
Cause: A physical disk
included in the virtual
disk failed or there is an
error in the parity
information. A failed
physical disk can cause
errors in parity
information.
Action: Replace the
failed physical disk. You
can identify which disk
has failed by locating
the disk that has a red
“X” for its status.
Rebuild the physical
disk. When finished,
restart the check
consistency operation.
Clear Alert
Number:
None
Related
Alert
Number:
None
LRA
Number:
2081
1204
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Vista de página 81
1 2 ... 77 78 79 80 81 82 83 84 85 86 87 ... 291 292

Comentários a estes Manuais

Sem comentários