Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Guia do Utilizador Página 188

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 292
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 187
188 Storage Management Message Reference
2307 Bad block table
is full. Unable
to log block %1
Critical /
Failure / Error
Cause: The bad block
table is used for
remapping bad disk
blocks. This table fills,
as bad disk blocks are
remapped. When the
table is full, bad disk
blocks can no longer be
remapped and disk
errors can no longer be
corrected. At this point,
data loss can occur. The
%1 indicates a
substitution variable.
The text for this
substitution variable is
displayed with the alert
in the alert log and can
vary depending on the
situation.
Action: Replace the
disk generating this
alert. If necessary,
restore your data from
backup.
Clear Alert:
None
Related
Alert
Number:
2048
LRA
Number:
2071
904
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Vista de página 187
1 2 ... 183 184 185 186 187 188 189 190 191 192 193 ... 291 292

Comentários a estes Manuais

Sem comentários