USER’S GUIDE
Managed Rack PDU
76
phRestrictn
Access: Administrator
Description: Set or view the overload restriction feature to prevent outlets from turning
on when the overload alarm threshold is violated. Acceptable arguments are none,
near, and over. To specify phases, choose from the following options. Type: all, a
single phase, a range, or a comma-separated list of phases.
Example 1: To set the overload restriction for phase three to none, type:
cli> phRestrictn 3 none
E000: Success
Example 2: To view the overload restrictions for all phases, type:
cli> phRestrictn all
E000: Success
1: over
2: near
3: none