cfgChassisPowerButtonEnable (Read/Write)
Description Indicates if the chassis power button is enabled or
disabled.
Legal Values
0 (disabled)
1 (enabled)
Default None
cfgChassisPowerCapBTU (Read/Write)
Description Indicates the maximum power consumption limit (in
BTU/hr) for the entire chassis. The command generates an
error if server throttling is necessary to achieve the power
goal based on the value for this setting.
Legal Values 9264 - 56931 BTU/hr
Default 43221 BTU/hr
cfgThermalEnhancedCoolingMode
Description Enables/disables the enhanced cooling mode
Legal Values
Enable: 1
Disable: 0
Default 0
cfgKVMInfo
This group is used to view the mapping information for the KVM.
Use this object with the config or getconfig subcommands.
To use this object property, you must have Chassis Configuration Administrator privilege.
cfgKvmMapping Read or Write
Description Maps the slots to the KVM.
Legal Values 1, 2, 3, and 4 are the slot numbers that are specified.
Default 1
cfgKvmSlot<num>Enable Read or Write
Description
Enable the slots (1 to 4) to access using KVM:
cfgKvmSlot1Enable