Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guia do Utilizador Página 126

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 155
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 125
iSCSI
VFLASH partition label
FDD
SDe
RFS (Remote File Share)
Default No-Override
cfgServerBootOnce (Read/Write)
Description Enables or disables the server boot once feature.
This object is Write only.
Legal Values
1 = TRUE
0 = FALSE
Default 0
cfgServerPowerConsumption (Read Only)
Description Displays the current power consumption for a server.
Legal Values None
Default None
Example
racadm getconfig -g cfgServerInfo -i 8
# cfgServerInfoIndex=8
# cfgServerSlotNumber=8
# cfgServerServiceTag=
cfgServerName=SLOT-08
# cfgServerFW=3.0
# cfgServerBIOS=
# cfgServerBmcMacAddress=00:21:9B:FE:5F:58
# cfgServerNic1MacAddress=00:0D:56:B8:69:63
170 CMC Property Database Group and Object Definitions
# cfgServerNic2MacAddress=00:0D:56:B8:69:65
# cfgServerNic3MacAddress=00:0D:56:B8:69:CB
# cfgServerNic4MacAddress=00:0D:56:B8:69:CD
cfgServerPriority=1
cfgServerNicEnable=1
cfgServerIPMIOverLANEnable=1
# cfgServerPowerBudgetAllocation=0
cfgServerDNSRegisterIMC=0
cfgServerDNSIMCName=iDRAC-
# cfgServerRootPassword=******** (Write-Only)
126
Vista de página 125
1 2 ... 121 122 123 124 125 126 127 128 129 130 131 ... 154 155

Comentários a estes Manuais

Sem comentários