Traps 721
Cooling Device Traps
Cooling device traps monitor how well a fan is functioning.
Table 27-4. Cooling Device Traps
Trap ID Description Severity Cause
Cooling Device Normal
1102 Fan sensor returned to a
normal value
Sensor location:
<Location in chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
Fan sensor value: <Reading>
Information A fan sensor reading
on the specified
system returned to a
valid range after
crossing a warning
threshold. The
sensor location,
chassis location,
previous state, and
fan sensor value are
provided.
Cooling Device Warning
1103 Fan sensor detected a
warning value
Sensor location:
<Location in chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
Fan sensor value: <Reading>
Warning A fan sensor reading
in the specified
system exceeded a
warning threshold.
The sensor location,
chassis location,
previous state, and
fan sensor value are
provided.