210 Thermal Group
Cooling Device Reading
Cooling Device Type
Cooling Device Location Name
Name coolingDeviceReading
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.6
Description Defines either the cooling device’s speed in revolutions
per minute (RPM), or the off/on value of the fan.
When the value for coolingDeviceSubType is other than
coolingDeviceSubTypeIsDiscrete, the value returned for this
attribute is the speed in RPM or the OFF/ON value of the cooling
device. When the value for coolingDeviceSubType is
coolingDeviceSubTypeIsDiscrete, a value is not returned for
this attribute.
Syntax DellSigned32BitRange
Access Read-only
Name coolingDeviceType
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.7
Description Defines the cooling device type.
Syntax DellCoolingDeviceType (See Table 10-1)
Access Read-only
Name coolingDeviceLocationName
Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.8
Description Defines the location of the cooling device in this chassis.
Syntax DellString
Access Read-only