Dell Computer Drive CMC 3.2 Manual do Utilizador Página 241

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 292
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 240
iDRAC6 and CMC Property Database Group and Object Descriptions 241
FILE LOCATION:
C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACADM\Source\rac
DELL CONFIDENTIAL – PRELIMINARY 3/26/13 - FOR PROOF ONLY
cfgServerPowerConsumptionClear (Write Only)
NOTE: This object is applicable only for iDRAC6.
cfgServerPowerCapWatts (Read/Write)
NOTE: This object is applicable only for iDRAC6.
cfgServerPowerCapBtuhr (Read/Write)
NOTE: This object is applicable only for iDRAC6.
cfgServerPowerCapPercent (Read/Write)
NOTE: This object is applicable only for iDRAC6.
Description Resets the cfgServerPeakPowerConsumption (Read/Write)
property to 0 and the cfgServerPeakPowerConsumptionTimestamp
property to the current iDRAC time.
Legal Values 1 (TRUE)
0 (FALSE)
Default None
Description Represents the server power threshold in Watts.
Legal Values A string of up to 32 characters.
Default Server power threshold in Watts.
Description Represents the server power threshold in BTU/hr.
Legal Values A string of up to 32 characters.
Default Server power threshold in BTU/hr.
Description Represents the server power threshold in percentage.
Legal Values A string of up to 32 characters.
Default Server power threshold in percentage.
Vista de página 240
1 2 ... 236 237 238 239 240 241 242 243 244 245 246 ... 291 292

Comentários a estes Manuais

Sem comentários