Dell Computer Drive CMC 3.2 Manual do Utilizador Página 232

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 292
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 231
232 iDRAC6 and CMC Property Database Group and Object Descriptions
FILE LOCATION:
C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACADM\Source\rac
DELL CONFIDENTIAL – PRELIMINARY 3/26/13 - FOR PROOF ONLY
cfgSystemEnergyConsumptionClear = ****(Write-Only)
racadm config -g cfgChassisPower
-o cfgChassisPowerClear 1
Clears
cfgChassisMinPower
and
cfgChassisPeakPower
.
cfgIpmiSol
This group is applicable only for iDRAC6 and is used to configure the Serial
Over LAN (SOL) capabilities of the system.
The following sections provides information about the objects in the
cfgIpmiSol group.
cfgIpmiSolEnable (Read/Write)
cfgIpmiSolBaudRate (Read/Write)
cfgIpmiSolMinPrivilege (Read/Write)
Description Enables or disables SOL.
Legal Values 1 (TRUE)
0 (FALSE)
Default 1
Description The baud rate for serial communication over LAN.
Legal Values 9600, 19200, 57600, 115200
Default 115200
Description Specifies the minimum privilege level required for SOL access.
Legal Values 2 (User)
3 (Operator)
4 (Administrator)
Default 4
Vista de página 231
1 2 ... 227 228 229 230 231 232 233 234 235 236 237 ... 291 292

Comentários a estes Manuais

Sem comentários