Dell PowerEdge RAID Controller S110 Manual do Utilizador Página 51

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 50
Troubleshooting 49
At the PERC BIOS Configuration Utility, select View Virtual Disk
Details and press <Enter>. Determine whether the physical disk that is
designated as the global hot spare has a status of Failed.
Check to see if the physical disk is malfunctioning or is physically
disconnected.
Select another physical disk as the global hot spare.
The physical disk assigned as the global hot spare is missing
Check to see if the physical disk was removed from the backplane or cable
connection, or whether the cables from the controller to the physical disk
are disconnected or faulty.
Perform a rescan to verify that the physical disk is still missing.
Physical Disk-Related Errors
The Physical Disk Fails
A physical disk is not visible in the PERC BIOS Configuration Utility or is
offline
Check that the cables are properly connected.
Check that the physical disk is installed properly in the system’s backplane.
Check the system’s backplane for damage.
Reinstall the physical disk and make sure that it is seated correctly in the
system’s backplane.
Check if the Physical Disk might be a SAS drive.
•Perform a
Rescan
, to (a) update the status of storage devices attached to
the controller, or (b) fix an error caused by deleting or initializing a virtual
disk.
A physical disk is highlighted red at the PERC BIOS Configuration Utility.
Replace the physical disk. Depending on the RAID level of the virtual disk,
data might be lost.
Perform a rescan to confirm that the new disk was discovered.
A5_bk0.book Page 49 Thursday, May 29, 2014 11:37 AM
Vista de página 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 75 76

Comentários a estes Manuais

Sem comentários