Dell PowerEdge C6100 Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Servidores Dell PowerEdge C6100. Dell PowerEdge C6100 Reference Guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Management Controller

Dell™ PowerEdge™ Systems Using the Baseboard Management Controller www . d e l l . c o m | su

Página 2

10 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m 2 In the Modify Alert window, complete the following

Página 3 - Contents

11 Using the Baseboard Management Controller Users The User List window displays the current list of configured users and allows you to add, modify,

Página 4

12 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m To add a user, complete these steps: 1 From the User

Página 5

13 Using the Baseboard Management Controller Table 1-5. Power Control Options Radio Button Description Reset Server Reboot server without powe

Página 6 - Using the Web User Interface

14 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Updating the BMC Firmware Through the GUI Before beginn

Página 7 - Remote Management Controller

15 Using the Baseboard Management Controller 9 When the upgrade is complete, the following message appears. Languages The Languages menu opti

Página 8

16 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m 2 Start the firmware update through TFTP by typing t

Página 9

17 Using the Baseboard Management Controller JViewer Menu The JViewer menu provides access to additional functions, outlined in the following tables

Página 10 - Network

18 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-9. Options Menu Items Menu Options Descrip

Página 11

19 Using the Baseboard Management Controller Table 1-12. BMC Messaging Support Commands (NETFUN: 06H, 07H) Commands NetFn CMD O/M Supported Get

Página 12 - Remote Control

Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

Página 13 - Maintenance

20 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-13. Firmware, Firewall and Discovery Command

Página 14

21 Using the Baseboard Management Controller Table 1-15. IMPI LAN Commands (NETFUN: 0CH, 0DH) Commands NetFn CMD O/M Supported Set LAN Configu

Página 15 - Languages

22 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-18. BMC Watchdog Timer Commands (NETFUN: 06H

Página 16 - Running Virtual Media

23 Using the Baseboard Management Controller Table 1-21. PEF and Alerting Commands (NETFUN: 04H, 05H) Commands NetFn CMD O/M Supported Get PEF C

Página 17 - JViewer Menu

24 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-23. SDR Repository Commands (NETFUN: 0AH, 0B

Página 18

25 Using the Baseboard Management Controller Table 1-25. Sensor Device Commands (NETFUN: 04H, 05H) Commands NetFn CMD O/M Supported Get Device SD

Página 19

26 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-26. Firmware Commands (NETFUN: 08H, 09H) Co

Página 20

27 Using the Baseboard Management Controller Table 1-27. Firmware Commands (NETFUN: 08H, 09H) Commands NetFn CMD Request and Response Get Upda

Página 21

28 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-28. Dell OEM Commands (NETFUN: 2CH, 2DH) Co

Página 22

29 Using the Baseboard Management Controller Table 1-29. Dell OEM Commands (NETFUN: 2EH, 2FH) Commands NetFn CMD Request and Response OemSetUboot

Página 23

Contents 3 Contents Intelligent Platform Management Interface . . . . . . . . . . . . . . . . . . . . 5 Baseb

Página 24

30 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-30. Dell OEM Commands (NETFUN: 30H, 31H) Co

Página 25

31 Using the Baseboard Management Controller Table 1-31. Dell OEM Commands (NETFUN: 30H, 31H) Commands NetFn CMD Request and Response Set Extend

Página 26

32 Using the Baseboard Management Controller Table 1-32. Dell OEM Commands (NETFUN: 30H, 31H) Commands NetFn CMD Request and Response Restore to

Página 27

33 Using the Baseboard Management Controller Table 1-33. Dell OEM Commands (NETFUN: 30H, 31H) Commands NetFn CMD Request and Response SETSYSTEMG

Página 28 - Byte 3 — Number

34 Using the Baseboard Management Controller www . del l . c o m | s u ppo rt. d e ll. c o m Table 1-35. Vendor OEM Commands (NETFUN: 34H, 35H

Página 29

35 Using the Baseboard Management Controller Table 1-36. Vendor OEM Commands (NETFUN: 34H, 35H) Commands NetFn CMD Request and Response SetFanCon

Página 30

36 Using the Baseboard Management Controller Table 1-37. Vendor OEM Commands (NETFUN: 34H, 35H) Commands NetFn CMD Request and Response SetFSCTab

Página 31

37 Using the Baseboard Management Controller Table 1-38. Vendor OEM Commands (NETFUN: 34H, 35H) Commands NetFn CMD Request and Response OEMPICmod

Página 32

38 Using the Baseboard Management Controller Table 1-39. Vendor OEM Commands (NETFUN: 34H, 35H) Commands NetFn CMD Request and Response Get Disab

Página 33

39 Using the Baseboard Management Controller Chassis Control Command Implementation Table 1-40. Chassis Control Command (NetFn=00/01, Cmd=02h) R

Página 34

4 Contents SSH/Telenet Enable and Disable 56 VLAN ID 57 BMC/BIOS Version Information. 58 BIOS Version Information 59

Página 35

40 Using the Baseboard Management Controller Entity ID and Instance Table Table 1-41. Entity ID and Instance Table Entity ID Entity Instance

Página 36

41 Using the Baseboard Management Controller 2Ah FCB Ambient1 Temperature (01h) Threshold (01h) 2Bh FCB Ambient2 www . del l . com | s u ppo rt.

Página 37

42 Using the Baseboard Management Controller 51h VCORE 1 Voltage (02h) Threshold (01h) 52h VCORE 2 Table 1-44. Sensor Summary Sensor Number S

Página 38

43 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-45. Sensor Summary Sensor Number Sensor Nam

Página 39

44 Using the Baseboard Management Controller Table 1-46. Sensor Summary Sensor Number Sensor Name Sensor Type Event/Reading Type Offset A3h PSU 1 P

Página 40 - Entity ID and Instance Table

45 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Threshold Settings and Converting Formulas Table 1-47.

Página 41 - Sensor Summary

46 Using the Baseboard Management Controller Table 1-48. Threshold Settings and Converting Formulas Sensor Number Sensor Name The Converting Fo

Página 42

47 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-49. Threshold Settings and Converting Formul

Página 43

48 Using the Baseboard Management Controller Power Throttling Function

Página 44

49 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Power Throttling Configuration in BIOS Setup Utility Be

Página 45

5 Using the Baseboard Management Controller Intelligent Platform Management Interface The Intelligent Platform Management Interface (IPMI) defines a

Página 46

50 Using the Baseboard Management Controller Extended Configurations Table 1-50. Configuration ID = 02h, NIC Attribute ID Size Description

Página 47

51 Using the Baseboard Management Controller Lockout Window 3 2 Specifies the window, in second, during which if the consecutive maximum number of

Página 48 - Power Throttling Function

52 Using the Baseboard Management Controller Table 1-54. Configuration ID = 0Ch, WEB Server Configuration Attribute ID Size Description Web Se

Página 49

53 Using the Baseboard Management Controller Entity 3 1 Specifies the entity of the controller. 0: BMC 1: SYSTEM (BIOS) 2: PDB 3

Página 50 - Extended Configurations

54 Using the Baseboard Management Controller Table 1-58. Configuration ID = 11h, Power Management Attribute ID Size e Description Power

Página 51

55 Using the Baseboard Management Controller Appendix SSH/Telnet Enable and Disable • Reserved extended configuration (NetFn: 30H CMD:01H) • Set/Get

Página 52

56 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Set SSH/Telnet enable: • Reserved extended configuratio

Página 53

57 Using the Baseboard Management Controller VLAN ID Use the LAN configuration command parameter 14H to set or get the VLAN ID. For additional infor

Página 54

58 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m BMC/BIOS Version Information The Get Device command is

Página 55 - Appendix

59 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m BIOS Version Information The BIOS enables the system in

Página 56 - Examples:

6 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Watchdog and Automatic System Recovery The BMC watchdog

Página 57 - VLAN ID

7 Using the Baseboard Management Controller Remote Management Controller The first time you access the Dell™ Remote Management Controller, you are pr

Página 58 - BMC/BIOS Version Information

8 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-2. List FRU Option Chassis Information Board

Página 59 - Example:

9 Using the Baseboard Management Controller • Set the email server IP address for sending alert notifications (SMTP button). • View information, c