Página 1 - Management Controller

Dell PowerEdge C5125Using the BaseboardManagement ControllerCOMMENT COMMENT COMMENT COMMENT COMMENT COMMENT COMMENT COMMENT

Página 2 - Typographic Conventions

10Server IdentifyThe Server Identify page displays the indicator LED status. You can select a Server Identify Operation to control the indicator LED f

Página 3 - Contents

11Firmware UpdateUse the Firmware Update feature to upgrade to the latest firmware version. The following data is included in the BMC firmware package

Página 4

126Click Start Upgrade.The update might take several minutes. When the update is completed, a dialog box appears.7Click OK to close the session and au

Página 5 - Using the Web UI

13Front Panel User InterfaceThe BMC provides control panel interface functionality including indicators (fault, status, and ID LEDs) and buttons (powe

Página 6

14ID LED Blue Off Normal status (by IPMI Chassis Identify command or System ID Button)Turn off the ID LED.1. ipmitool raw 0x00 0x04 0x002. ipmitool ra

Página 7 - System Features

15Table 1-5. Blinking Fault LED ConditionsIndex Sensor Name Event Triggers1 CPU0_Temp,• Upper Critical Going High.• Upper Non-Critical Going High.Ambi

Página 8

16System InformationSystem InformationThe System Information page shows general information about the system including Device Power Status, Firmware R

Página 9

17Component InformationThe Component Information page shows a table of the components. The components can be filtered by category and can be sorted by

Página 10 - Server Identify

18Server HealthThe Server Health page provides information about the server’s health such as sensor readings and the event log. The sensor readings ca

Página 11 - Firmware Update

19Sensor ReadingsThe Sensor Readings page shows all sensor readings from the system. NOTE: The sensor type category displays the full sensor (thresho

Página 12

Typographic ConventionsSeveral different typographic conventions are used throughout this manual. Refer to the following examples for common usage.Bol

Página 13 - Front Panel User Interface

20Sensor Readings With ThresholdsThe Sensor Readings with Thresholds page shows all sensor readings and thresholds from the system.Show Thresholds But

Página 14

21Temperature MonitoringThe system supports the following temperature sensors. Table 1-8. Sensor Readings With ThresholdsItem DescriptionSensor Select

Página 15

22FAN Control and MonitoringThe BMC receives all fan tachometers of the threshold base from the chassis controller. The following is the table of the

Página 16 - System Information

23Event LogThe Event Log page shows the event logs from the managed system. NOTE: If the event log belongs to the OEM SEL Record, the Sensor Type fie

Página 17 - Component Information

24ConfigurationThe Configuration menu allows you to access various configuration settings including Alerts, Mouse Mode, Network, SOL, SNMP, SMTP, User

Página 18 - Server Health

25SMTP This button takes you to the SMTP settings page where you can configure the SMTP mail server.Users This button takes you to the User List page

Página 19 - Sensor Readings

26AlertsWhen BMC sends a platform event, such as an environment warning or a component failure, an alert message may be sent to one or more email addr

Página 20

27Modify AlertTable 1-15. Modify AlertsItems DescriptionAlert Type You can select the way an alert is sent when it is triggered by an event.•SNMP Trap

Página 21 - Temperature Monitoring

28Mouse ModeOn the Mouse Mode page, you can configure the mouse mode options.IPMI is an OS-independent platform, and KVM support is an added feature f

Página 22 - FAN Control and Monitoring

29coordinates on your host server. For example, it is recommended to use absolute / relative mouse mode when your host server is running in Windows or

Página 23 - Event Log

3ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Supported Platform . . . . . . . . . . . . . . . . . . . . . .

Página 24 - Configuration

30NetworkThe Network page allows you to view and modify the network settings. Select whether to obtain an IP address automatically or manually configu

Página 25

31 NOTE: If you configure the IP address with a static IP, you cannot get the DNS IP address from the DHCP server. NOTE: If you want to update the DN

Página 26

32 VLAN SettingsTable 1-18. VLAN SettingsItems DescriptionEnable VLAN Enable / disable VLAN function.Note: If enabled, BMC will only accept packets fo

Página 27 - Modify Alert

33SOLThe SOL page allows you to configure the Serial Over LAN settings, select or change pertinent values for each attribute and save any changes.Tabl

Página 28 - Mouse Mode

34SOL Advanced SettingsTable 1-20. Advanced SOL settingsItem DescriptionCharacter Accumulate IntervalThe amount of time that the BMC will wait before

Página 29

35SNMPThe SNMP page displays the community string page for the SNMP trap server. You can modify the community string and save the new settings.Table 1

Página 30

36SMTPThe SMTP page allows you to configure the SMTP mail server.Table 1-22. SMTPItem DescriptionMail Server IP This field allows you to configure the

Página 31

37UsersThe Users page allows you to view the current list of user for the server. If you would like to delete or modify a user, select their name in t

Página 32 - VLAN Settings

38Add New UserThis page allows you to enter the required information for a new user. Enter the information for the new user and click the Add button.

Página 33

39Modify UserTable 1-25. Modify UserItem DescriptionUser Name This field contains the user name being modified. This field cannot be modified.Change P

Página 34 - SOL Advanced Settings

4SOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SNMP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35SMTP. .

Página 35

40PEFThe PEF page allows you to configure the platform event filters. The Platform Event Filters List displays the actions that will execute when an e

Página 36 - Item Description

41Modify PEFChange the attributes, and click the Save button to save any changes. If you want to cancel this action, click the Cancel button to return

Página 37

42SSL CertificateThe SSL Certificate page allows you upload a new SSL certificate. NOTE: The SSL page does not support encryption of private keys, f

Página 38 - Add New User

43Web SessionThe Web Session page allows you to change web session time out values. The default value is 300 seconds. If you don't active web wit

Página 39 - Modify User

44Remote ControlThe Remote Control menu allows you to initiate Console Redirection and to view the Power Control options. NOTE: The Console Redirecti

Página 40

45Table 1-30. Console Redirection, Java Console LaunchItem DescriptionJava Console Use this button to launch the redirection console using Java viewer

Página 41 - Modify PEF

46Left Windows Key This menu item can be used to act as the left-side <WIN> key when in Console Redirection. You can also decide how the key sho

Página 42 - SSL Certificate

47Table 1-34. Console Redirection Window: OptionsItem DescriptionBandwidth The bandwidth usage option allows you to adjust the bandwidth. You can sele

Página 43 - Web Session

48Power ControlThe Power Control page allows you to view and control the power of your server. Select one of the options listed in the following table

Página 44 - Remote Control

49MaintenanceThe Maintenance menu allows you to perform maintenance tasks on the device including the Firmware Update. Refer to "Firmware Update&

Página 45

5IntroductionThis section introduces the Baseboard Management Controller (BMC) and includes the requirements for web-based graphical user interface (G

Página 46

50IPMI 1.5 / 2.0 Command Support ListTable 1-38. IPMI Device Global CommandsCommand NetFn CMD O/M SupportedGet Device ID App 01h M YesCold Reset App 0

Página 47

51Get Channel Authentication CapabilitiesApp 38h M YesGet Session Challenge App 39h M YesActivate Session Command App 3Ah M YesSet Session Privilege L

Página 48 - Power Control

52Get Channel Cipher Suites App 54h O YesSuspend/Resume Payload EncryptionApp 55h O YesSet Channel Security Keys App 56h O YesGet System Interface Cap

Página 49 - Languages

53 NOTE: Support for Partial Add SEL is not required when Add SEL is supported.Table 1-42. Event CommandsCommand NetFn CMD O/M SupportedSet Event Rec

Página 50

54Table 1-44. SDR Repository CommandsCommand NetFn CMD O/M SupportedGet SDR Repository Info Storage 20h M YesGet SDR Repository Allocation InfoStorage

Página 51

55Table 1-46. Sensory Device CommandsCommand NetFn CMD O/M SupportedGet Device SDR Info S/E 20h O NoGet Device SDR S/E 21h O NoReserve Device SDR Repo

Página 52

56Table 1-48. SOL CommandsCommand NetFn CMD O/M SupportedSOL Activating Transport 20h O NoSet SOL Configuration ParametersTransport 21h O YesGet SOL C

Página 53

6Web-based GUI is supported on the following browsers:Microsoft Windows:• Internet Explorer 6, 7 or later• Mozilla Firefox 2.0 or laterLinux:• Mozilla

Página 54

7 NOTE: The default username and password are in lowercase characters. It is advised to change the root password once you have logged in.Click the He

Página 55

8Table 1-2. BMC SummaryBMC Information DescriptionDevice Power Status Current power state of the system.Firmware Revision Dell Remote Management Cont

Página 56

9Component InformationThe Number of CPU Socket field and the Number of Memory Slot field display the total number of the motherboard supported.CPU Inf