Dell PowerEdge C5125Using the BaseboardManagement ControllerCOMMENT COMMENT COMMENT COMMENT COMMENT COMMENT COMMENT COMMENT
10Server IdentifyThe Server Identify page displays the indicator LED status. You can select a Server Identify Operation to control the indicator LED f
11Firmware UpdateUse the Firmware Update feature to upgrade to the latest firmware version. The following data is included in the BMC firmware package
126Click Start Upgrade.The update might take several minutes. When the update is completed, a dialog box appears.7Click OK to close the session and au
13Front Panel User InterfaceThe BMC provides control panel interface functionality including indicators (fault, status, and ID LEDs) and buttons (powe
14ID LED Blue Off Normal status (by IPMI Chassis Identify command or System ID Button)Turn off the ID LED.1. ipmitool raw 0x00 0x04 0x002. ipmitool ra
15Table 1-5. Blinking Fault LED ConditionsIndex Sensor Name Event Triggers1 CPU0_Temp,• Upper Critical Going High.• Upper Non-Critical Going High.Ambi
16System InformationSystem InformationThe System Information page shows general information about the system including Device Power Status, Firmware R
17Component InformationThe Component Information page shows a table of the components. The components can be filtered by category and can be sorted by
18Server HealthThe Server Health page provides information about the server’s health such as sensor readings and the event log. The sensor readings ca
19Sensor ReadingsThe Sensor Readings page shows all sensor readings from the system. NOTE: The sensor type category displays the full sensor (thresho
Typographic ConventionsSeveral different typographic conventions are used throughout this manual. Refer to the following examples for common usage.Bol
20Sensor Readings With ThresholdsThe Sensor Readings with Thresholds page shows all sensor readings and thresholds from the system.Show Thresholds But
21Temperature MonitoringThe system supports the following temperature sensors. Table 1-8. Sensor Readings With ThresholdsItem DescriptionSensor Select
22FAN Control and MonitoringThe BMC receives all fan tachometers of the threshold base from the chassis controller. The following is the table of the
23Event LogThe Event Log page shows the event logs from the managed system. NOTE: If the event log belongs to the OEM SEL Record, the Sensor Type fie
24ConfigurationThe Configuration menu allows you to access various configuration settings including Alerts, Mouse Mode, Network, SOL, SNMP, SMTP, User
25SMTP This button takes you to the SMTP settings page where you can configure the SMTP mail server.Users This button takes you to the User List page
26AlertsWhen BMC sends a platform event, such as an environment warning or a component failure, an alert message may be sent to one or more email addr
27Modify AlertTable 1-15. Modify AlertsItems DescriptionAlert Type You can select the way an alert is sent when it is triggered by an event.•SNMP Trap
28Mouse ModeOn the Mouse Mode page, you can configure the mouse mode options.IPMI is an OS-independent platform, and KVM support is an added feature f
29coordinates on your host server. For example, it is recommended to use absolute / relative mouse mode when your host server is running in Windows or
3ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Supported Platform . . . . . . . . . . . . . . . . . . . . . .
30NetworkThe Network page allows you to view and modify the network settings. Select whether to obtain an IP address automatically or manually configu
31 NOTE: If you configure the IP address with a static IP, you cannot get the DNS IP address from the DHCP server. NOTE: If you want to update the DN
32 VLAN SettingsTable 1-18. VLAN SettingsItems DescriptionEnable VLAN Enable / disable VLAN function.Note: If enabled, BMC will only accept packets fo
33SOLThe SOL page allows you to configure the Serial Over LAN settings, select or change pertinent values for each attribute and save any changes.Tabl
34SOL Advanced SettingsTable 1-20. Advanced SOL settingsItem DescriptionCharacter Accumulate IntervalThe amount of time that the BMC will wait before
35SNMPThe SNMP page displays the community string page for the SNMP trap server. You can modify the community string and save the new settings.Table 1
36SMTPThe SMTP page allows you to configure the SMTP mail server.Table 1-22. SMTPItem DescriptionMail Server IP This field allows you to configure the
37UsersThe Users page allows you to view the current list of user for the server. If you would like to delete or modify a user, select their name in t
38Add New UserThis page allows you to enter the required information for a new user. Enter the information for the new user and click the Add button.
39Modify UserTable 1-25. Modify UserItem DescriptionUser Name This field contains the user name being modified. This field cannot be modified.Change P
4SOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SNMP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35SMTP. .
40PEFThe PEF page allows you to configure the platform event filters. The Platform Event Filters List displays the actions that will execute when an e
41Modify PEFChange the attributes, and click the Save button to save any changes. If you want to cancel this action, click the Cancel button to return
42SSL CertificateThe SSL Certificate page allows you upload a new SSL certificate. NOTE: The SSL page does not support encryption of private keys, f
43Web SessionThe Web Session page allows you to change web session time out values. The default value is 300 seconds. If you don't active web wit
44Remote ControlThe Remote Control menu allows you to initiate Console Redirection and to view the Power Control options. NOTE: The Console Redirecti
45Table 1-30. Console Redirection, Java Console LaunchItem DescriptionJava Console Use this button to launch the redirection console using Java viewer
46Left Windows Key This menu item can be used to act as the left-side <WIN> key when in Console Redirection. You can also decide how the key sho
47Table 1-34. Console Redirection Window: OptionsItem DescriptionBandwidth The bandwidth usage option allows you to adjust the bandwidth. You can sele
48Power ControlThe Power Control page allows you to view and control the power of your server. Select one of the options listed in the following table
49MaintenanceThe Maintenance menu allows you to perform maintenance tasks on the device including the Firmware Update. Refer to "Firmware Update&
5IntroductionThis section introduces the Baseboard Management Controller (BMC) and includes the requirements for web-based graphical user interface (G
50IPMI 1.5 / 2.0 Command Support ListTable 1-38. IPMI Device Global CommandsCommand NetFn CMD O/M SupportedGet Device ID App 01h M YesCold Reset App 0
51Get Channel Authentication CapabilitiesApp 38h M YesGet Session Challenge App 39h M YesActivate Session Command App 3Ah M YesSet Session Privilege L
52Get Channel Cipher Suites App 54h O YesSuspend/Resume Payload EncryptionApp 55h O YesSet Channel Security Keys App 56h O YesGet System Interface Cap
53 NOTE: Support for Partial Add SEL is not required when Add SEL is supported.Table 1-42. Event CommandsCommand NetFn CMD O/M SupportedSet Event Rec
54Table 1-44. SDR Repository CommandsCommand NetFn CMD O/M SupportedGet SDR Repository Info Storage 20h M YesGet SDR Repository Allocation InfoStorage
55Table 1-46. Sensory Device CommandsCommand NetFn CMD O/M SupportedGet Device SDR Info S/E 20h O NoGet Device SDR S/E 21h O NoReserve Device SDR Repo
56Table 1-48. SOL CommandsCommand NetFn CMD O/M SupportedSOL Activating Transport 20h O NoSet SOL Configuration ParametersTransport 21h O YesGet SOL C
6Web-based GUI is supported on the following browsers:Microsoft Windows:• Internet Explorer 6, 7 or later• Mozilla Firefox 2.0 or laterLinux:• Mozilla
7 NOTE: The default username and password are in lowercase characters. It is advised to change the root password once you have logged in.Click the He
8Table 1-2. BMC SummaryBMC Information DescriptionDevice Power Status Current power state of the system.Firmware Revision Dell Remote Management Cont
9Component InformationThe Number of CPU Socket field and the Number of Memory Slot field display the total number of the motherboard supported.CPU Inf