Dell OpenManage Server Administrator Version 5.4 Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Servidores Dell OpenManage Server Administrator Version 5.4. Dell OpenManage Server Administrator Version 5.4 User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 258
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1 - User's Guide

www.dell.com | support.dell.comDell™ OpenManage™Server Administrator Version 5.4Command Line InterfaceUser's Guide

Página 2 - Notes and Notices

10 Contentsomconfig Controller Commands . . . . . . . . . . . . . 143omconfig Rescan Controller . . . . . . . . . . . . 145omconfig Enable Controlle

Página 3 - Contents

98 omconfig: Managing Components Using the Instrumentation ServiceThe parameters for configuring the SNMP root password are the same whether you confi

Página 4 - 4 Contents

omconfig: Managing Components Using the Instrumentation Service 99omconfig preferences useraccessDepending on the policies of your enterprise, you may

Página 5

100 omconfig: Managing Components Using the Instrumentation ServiceFor example, if a fan probe on your system reads a fan RPM of 300 and your minimum

Página 6 - 6 Contents

omconfig: Managing Components Using the Instrumentation Service 101Components and Events for Which You Can Set Alert ActionsTable 4-21 lists the compo

Página 7

102 omconfig: Managing Components Using the Instrumentation Service NOTE: storagectrlbatterywarn and storagectrlbatteryfail events are not available

Página 8 - 8 Contents

omconfig: Managing Components Using the Instrumentation Service 103To enable broadcast messages if a current probe detects a failure event, type:omcon

Página 9

104 omconfig: Managing Components Using the Instrumentation ServiceTo clear the contents of the command log, type:omconfig system cmdlog action=clearo

Página 10 - 10 Contents

omconfig: Managing Components Using the Instrumentation Service 105Table 4-23 shows the valid parameters for the command. NOTE: Alert settings are mu

Página 11

106 omconfig: Managing Components Using the Instrumentation Serviceevent=fanfail Sets action or enables/disables alert generation when a fan probe det

Página 12 - 12 Contents

omconfig: Managing Components Using the Instrumentation Service 107omconfig system events/omconfig servermodule eventsUse the omconfig system events o

Página 13 - Introduction

Contents 11omconfig Check Consistency . . . . . . . . . . . 167omconfig Cancel Check Consistency . . . . . . . 168omconfig Pause Check Consistency.

Página 14 - Primary CLI Commands

108 omconfig: Managing Components Using the Instrumentation ServiceTyp eType refers to the name of the component(s) involved in the event. Table 4-25

Página 15

omconfig: Managing Components Using the Instrumentation Service 109IndexIndex refers to the number of an event for a particular component. Index is an

Página 16 - Failure Messages

110 omconfig: Managing Components Using the Instrumentation Serviceomconfig system recovery/omconfig servermodule recoveryUse the omconfig system reco

Página 17 - Introduction 17

omconfig: Managing Components Using the Instrumentation Service 111the file system before powering the system down. If you do not want to shut down th

Página 18

112 omconfig: Managing Components Using the Instrumentation ServiceTable 4-30 shows the valid parameters for the command.Example Thermal Shutdown Comm

Página 19 - Command Syntax Overview

omconfig system or servermodule assetinfo: Editing Cost of Ownership Values 113omconfig system or servermodule assetinfo: Editing Cost of Ownership Va

Página 20

114 omconfig system or servermodule assetinfo: Editing Cost of Ownership ValuesAdding Acquisition InformationAcquisition refers to the facts about a b

Página 21 - Introduction 21

omconfig system or servermodule assetinfo: Editing Cost of Ownership Values 115Example Commands for Adding Acquisition InformationTo provide a value f

Página 22 - 22 Introduction

116 omconfig system or servermodule assetinfo: Editing Cost of Ownership ValuesAdding Depreciation InformationDepreciation is a set of methods for com

Página 23 - Using the omhelp Command

omconfig system or servermodule assetinfo: Editing Cost of Ownership Values 117The following message appears:Asset information set successfully.You ca

Página 24

12 Contentsomconfig Enclosure Commands . . . . . . . . . . . . . 188omconfig Enable Enclosure Alarm. . . . . . . . . 188omconfig Disable Enclosure A

Página 25 - Using the omhelp Command 23

118 omconfig system or servermodule assetinfo: Editing Cost of Ownership ValuesExample Command for Adding Extended Warranty InformationTo provide a va

Página 26 - 24 Using the omhelp Command

omconfig system or servermodule assetinfo: Editing Cost of Ownership Values 119Example Command for Adding Lease InformationTo provide a value for a le

Página 27

120 omconfig system or servermodule assetinfo: Editing Cost of Ownership ValuesExample Command for Adding Maintenance InformationTo provide a value fo

Página 28

omconfig system or servermodule assetinfo: Editing Cost of Ownership Values 121Adding Outsource InformationOutsourcing is the practice of contracting

Página 29

122 omconfig system or servermodule assetinfo: Editing Cost of Ownership ValuesYou can enter more than one omconfig system assetinfo or omconfig serve

Página 30

omconfig system or servermodule assetinfo: Editing Cost of Ownership Values 123You can enter more than one omconfig system assetinfo or omconfig serve

Página 31

124 omconfig system or servermodule assetinfo: Editing Cost of Ownership ValuesYou can enter more than one omconfig system assetinfo or omconfig serve

Página 32

omconfig system or servermodule assetinfo: Editing Cost of Ownership Values 125Example Command for Adding Support InformationTo provide a value for a

Página 33

126 omconfig system or servermodule assetinfo: Editing Cost of Ownership ValuesExample Command for Adding System InformationTo provide a value for a s

Página 34

omconfig system or servermodule assetinfo: Editing Cost of Ownership Values 127Adding Warranty InformationUse the omconfig system warranty or omconfig

Página 35

Introduction 13IntroductionUsing Dell™ OpenManage™ Server Administrator’s graphical user interface (GUI) or the command line interface (CLI) you can p

Página 36

128 omconfig system or servermodule assetinfo: Editing Cost of Ownership ValuesThe following message appears:Asset information set successfully.You ca

Página 37

Using the Storage Management Service 129Using the Storage Management ServiceThe CLI of Storage Management enables you to perform all of Storage Manage

Página 38

130 Using the Storage Management ServiceTable 6-1 describes these command levels. Following the command levels, the omreport and omconfig command synt

Página 39

Using the Storage Management Service 131Table 6-2. Syntax For Name=Value Pairs For ParametersSyntax Description controller=id Indicates the controller

Página 40

132 Using the Storage Management ServiceUser Privileges for omreport storage and omconfig storageStorage Management requires Administrator privileges

Página 41

Using the Storage Management Service 133omreport Storage Help Table 6-3 provides the omreport storage command syntax. omreport Controller StatusTable

Página 42

134 Using the Storage Management Serviceomreport Global Information (Smart Thermal Shutdown Status)Table 6-5 describes the syntax for the omreport Glo

Página 43

Using the Storage Management Service 135omreport Connector Status Table 6-7describes the syntax for the omreport Connector Commands.omreport Enclosure

Página 44

136 Using the Storage Management Serviceomreport Temperature Probe StatusTable 6-9 describes the syntax for the omreport Probe CommandsTable 6-9. omre

Página 45

Using the Storage Management Service 137omreport Fan StatusTable 6-10 describes the syntax for the omreport Fan CommandsTable 6-10. omreport Fan Statu

Página 46

14 Introductionversions 5.4 of the Dell OpenManage Server Administrator and Dell OpenManage Management Station software. You can use these ISO images

Página 47

138 Using the Storage Management Serviceomreport Power Supply StatusTable 6-11 describes the syntax for the omreport Power Supply CommandsTable 6-11.

Página 48

Using the Storage Management Service 139omreport EMM StatusTable 6-12 describes the syntax for the omreport EMM CommandsTable 6-12. omreport EMM Comma

Página 49

140 Using the Storage Management Serviceomreport Physical Disk Status Table 6-13 describes the syntax for the omreport Physical Disk CommandsTable 6-1

Página 50

Using the Storage Management Service 141omreport Virtual Disk Status Table 6-14 describes the syntax for the omreport Virtual Disk Commandsomconfig Gl

Página 51

142 Using the Storage Management Servicetemperature of 0 or 50° Celsius. Specifying that only the enclosure be shut down during excessive temperatures

Página 52 - Critical : Storage

Using the Storage Management Service 143Example SyntaxThe omconfig command syntax for disabling thermal shutdown does not require that you specify a c

Página 53 - Commands for Viewing Logs

144 Using the Storage Management ServiceTable 6-16. omconfig Controller CommandsRequired Command Levels (1, 2, 3) Optional name=value pairs omconfig s

Página 54

Using the Storage Management Service 145omconfig Rescan Controller Use the following omconfig command syntax to rescan a controller. See Dell OpenMana

Página 55

146 Using the Storage Management Serviceomconfig Disable Controller Alarm Use the following omconfig command syntax to disable the controller alarm. S

Página 56

Using the Storage Management Service 147omconfig Test Controller Alarm Use the following omconfig command syntax to test the functionality of the cont

Página 57

Introduction 15The omhelp command displays short text help for CLI commands. The shorthand equivalent of omhelp is the command for which you want help

Página 58

148 Using the Storage Management ServiceExample Syntax To reset the configuration on controller 1, enter: omconfig storage controller action=resetconf

Página 59

Using the Storage Management Service 149Parameter Specification for Create and Reconfigure Virtual Disk The following sections indicate how to specify

Página 60 - Example Command Output

150 Using the Storage Management Servicesize=<number | max | min> Parameter (Required) Table 6-18 indicates how to specify the size=<number |

Página 61 - System Attributes

Using the Storage Management Service 151Different controllers support different stripe sizes. See Dell OpenManage Online Help for more information on

Página 62 - Firmware

152 Using the Storage Management Service[writepolicy=<wb| wt| wc| nwc>] Parameter (Optional) Different controllers support different write polic

Página 63 - Storage Enclosures

Using the Storage Management Service 153The virtual disk will be 500 MB with a stripe size of 16 KB. The name of the virtual disk will be vd1 and it w

Página 64

154 Using the Storage Management ServiceComplete Syntaxomconfig storage controller action=setbgirate controller=id rate=<0 to 100>where id is th

Página 65

Using the Storage Management Service 155Complete Syntaxomconfig storage controller action=setcheckconsistency controller=idrate=<0 to 100>where

Página 66

156 Using the Storage Management ServiceDepending on the controller, the log file name will either be afa_<mmdd>.log or lsi_<mmdd>.log whe

Página 67

Using the Storage Management Service 157Example Syntax To import and recover foreign configurations on controller 1, enter: omconfig storage controlle

Página 68

16 IntroductionCLI Error Checking and Error MessagesWhen you type CLI commands, the CLI checks these commands for correct syntax. If you enter a comma

Página 69

158 Using the Storage Management ServiceExample SyntaxTo set the patrol read on controller 1 to manual mode, enter:omconfig storage controller action=

Página 70

Using the Storage Management Service 159Example SyntaxTo stop the patrol read task on controller 1, enter:omconfig storage controller action=stoppatro

Página 71

160 Using the Storage Management Serviceomconfig Blink Virtual Disk Use the following omconfig command syntax to blink the physical disks included in

Página 72

Using the Storage Management Service 161Complete Syntax omconfig storage vdisk action=unblink controller=id vdisk=id where id is the controller ID and

Página 73

162 Using the Storage Management ServiceComplete Syntax omconfig storage vdisk action=cancelinitialize controller=id vdisk=idwhere id is the controlle

Página 74

Using the Storage Management Service 163Complete Syntax omconfig storage vdisk action=slowinit controller=id vdisk=id where id is the controller ID an

Página 75

164 Using the Storage Management ServiceComplete Syntax omconfig storage vdisk action=restoresegments controller=id vdisk=id where id is the controlle

Página 76

Using the Storage Management Service 165omconfig Unmirror Use the following omconfig command syntax to separate mirrored data and restore one half of

Página 77

166 Using the Storage Management ServiceTo obtain the values for the controller, virtual disk, and physical disk, enter omreport storage controller to

Página 78

Using the Storage Management Service 167To obtain the values for the controller, virtual disk, and physical disk, enter omreport storage controller to

Página 79

Introduction 17If you try to execute a command for a component or feature not present in your system configuration, the error message states that the

Página 80

168 Using the Storage Management ServiceExample Syntax To run a check consistency on virtual disk 4 on controller 1, enter: omconfig storage vdisk act

Página 81

Using the Storage Management Service 169Example Syntax To pause a check consistency on virtual disk 4 on controller 1, enter: omconfig storage vdisk a

Página 82

170 Using the Storage Management Serviceomconfig Format Virtual Disk Use the following omconfig command syntax to format a virtual disk. Complete Synt

Página 83

Using the Storage Management Service 171Example for SCSI, SATA, and ATA Controllers In this example, enter: omconfig storage vdisk action=reconfigure

Página 84

172 Using the Storage Management ServiceExample Syntax To change the read policy of virtual disk 4 on controller 1 to no-read-ahead, enter: omconfig s

Página 85 - Default Warning Thresholds

Using the Storage Management Service 173omconfig Blink Physical Disk You can blink the light (light emitting diode or LED display) on one or more phys

Página 86

174 Using the Storage Management ServiceExample for SAS Controllers To blink the physical disk described in this example, enter: omconfig storage pdis

Página 87

Using the Storage Management Service 175omconfig Prepare to Remove Physical Disk Use the following omconfig command syntax to prepare a physical disk

Página 88

176 Using the Storage Management Serviceomconfig Initialize Physical Disk Use the following omconfig command syntax to initialize a physical disk. Com

Página 89

Using the Storage Management Service 177omconfig Offline Physical Disk Use the following omconfig command syntax to offline a physical disk: Complete

Página 90

18 Introductionwarning or failure event. In the most critical cases, the administrator could write a script so that the system shuts down to prevent d

Página 91

178 Using the Storage Management ServiceExample Syntax In this example, you want to offline physical disk 3 on connector 0 of controller 1. On a SAS c

Página 92

Using the Storage Management Service 179Example for SAS Controllers To bring the physical disk described in this example back online, enter: omconfig

Página 93

180 Using the Storage Management Serviceomconfig Unassign Global Hot Spare Use the following omconfig command syntax to unassign a physical disk as a

Página 94 - NOTE: extimpiusergroup

Using the Storage Management Service 181Complete Syntax omconfig storage pdisk action=rebuild controller=id pdisk=<PDISKID> where id is the cont

Página 95

182 Using the Storage Management ServiceTo obtain these values, enter omreport storage controller to display the controller IDs and then enter omrepor

Página 96

Using the Storage Management Service 183Example Syntax In this example, you want to remove dead disk segments on physical disk 3 on connector 0 of con

Página 97

184 Using the Storage Management ServiceExample for SAS Controllers To clear the physical disk described in this example, enter: omconfig storage pdis

Página 98

Using the Storage Management Service 185omconfig Battery Commands The following sections provide the omconfig command syntax required to execute batte

Página 99

186 Using the Storage Management Servicewhere id is the controller ID and battery ID as reported by the omreport command. To obtain this value, enter

Página 100

Using the Storage Management Service 187omconfig Connector Commands The following sections provide the omconfig command syntax required to execute con

Página 101 - Defining Alert Actions

Introduction 19Command Syntax OverviewCommands vary in complexity. The simplest command has only command level 1. The omhelp command is a simple comma

Página 102 - Available Alert Actions

188 Using the Storage Management Serviceomconfig Enclosure Commands The following sections provide the omconfig command syntax required to execute enc

Página 103

Using the Storage Management Service 189Example for SCSI, SATA, and ATA Controllers To enable the alarm on the enclosure attached to connector 2 on co

Página 104 - Example Current Probe Actions

190 Using the Storage Management Serviceomconfig Set Enclosure Asset Tag Use the following omconfig command syntax to specify the enclosure’s asset ta

Página 105 - Commands for Clearing Logs

Using the Storage Management Service 191Example for SCSI, SATA, and ATA Controllers To specify the asset name to encl43 for the enclosure attached to

Página 106

192 Using the Storage Management ServiceExample for SCSI, SATA, and ATA Controllers In this example, temperature probe 3 resides in the enclosure atta

Página 107

Using the Storage Management Service 193Complete Syntaxomconfig storage enclosure action=setalltempprobes controller=id enclosure=<ENCLOSUREID>

Página 108

194 Using the Storage Management ServiceExample for SAS Controllers In this example, the temperature probes reside in enclosure 3 attached to connecto

Página 109

Working With CLI Command Results 195Working With CLI Command ResultsServer Administrator Command Line Interface (CLI) users can use the command output

Página 110 - Severity

196 Working With CLI Command ResultsSUSE® Linux Enterprise Server terminal. To display command output with control over scrolling, type the CLI comman

Página 111

Working With CLI Command Results 197Four hours later, you repeat the command. You have no interest in the 11:00 A.M. snapshot as written to fans.txt.

Página 112 - Example Recovery Commands

Notes and Notices NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE: A NOTICE indicates either pot

Página 113 - Example Shutdown Commands

20 IntroductionAn example of nine name=value pairs:omconfig system assetinfo info=acquisitionpurchasecost=<n> waybill=<n> installdate=<

Página 114

198 Working With CLI Command ResultsYou can use a text editor to insert the time that each block of data was captured. In comparing the two snapshots

Página 115 - Ownership Values

Working With CLI Command Results 199The Syntax for the formatting option is:<command> -fmt <format option>For example, type:omreport syste

Página 116

200 Working With CLI Command ResultsNetwork Interface Card 0 DataIP Address: 143.166.152.108Subnet Mask: 255.255.255.0Default Gateway: 143.166.152.1MA

Página 117

Working With CLI Command Results 201The example output displays as follows:------------------------------Network Data------------------------------Net

Página 118

202 Working With CLI Command ResultsCustom Delimited Format (cdv)Use the cdv formatting option to report exported data in custom delimited format. You

Página 119

Glossary 203GlossaryThe following list defines or identifies technical terms, abbreviations, and acronyms used in Dell™user documents.AAbbreviation fo

Página 120 - Adding Lease Information

204 GlossaryASICAcronym for application-specific integrated circuit.ASPIAdvanced SCSI programming interface.ASRAbbreviation for automatic system recov

Página 121

Glossary 205backupA copy of a program or data file. As a precaution, back up your computer's hard drive on a regular basis. Before changing the c

Página 122

206 Glossarybootable disketteYou can start your computer from a diskette. To make a bootable diskette, insert a diskette in the diskette drive, type s

Página 123 - Adding Outsource Information

Glossary 207capabilityRefers to the actions that an object can perform, or actions that can be taken on a managed object. For example, if a card is ho

Página 125

208 GlossaryCIMOMAcronym for common information model object manager.CI/OAcronym for comprehensive input/output.cmAbbreviation for centimeter(s).CMCAc

Página 126 - Adding Support Information

Glossary 209control panelThe part of the computer that contains indicators and controls, such as the power switch, hard drive access indicator, and po

Página 127 - Adding System Information

210 Glossarycompany wants to generate its own CSR, you can request a unique CSR from a certificate authority and overwrite the Dell CSR.cursorA marker

Página 128

Glossary 211DINAcronym for Deutsche Industrie Norm which is the standards-setting organization in Germany. A DIN connector is a connector that conform

Página 129 - Adding Warranty Information

212 GlossaryDRACRefers to a remote management capability. See RAC.DRAMAcronym for dynamic random-access memory. A computer's RAM is usually made

Página 130

Glossary 213• Data transfer rates of up to 16 MB/sec• Support for drives other than just hard drives, such as CD drives• Support for hard drives with

Página 131 - Using the Storage Management

214 GlossaryERAAcronym for embedded remote access.ERA/OAcronym for embedded remote access option.ESDAbbreviation for electrostatic discharge.ESMAcrony

Página 132 - Command Elements

Glossary 215FATAcronym for file allocation table. The file system structure used by MS-DOS to organize and keep track of file storage. The Windows NT®

Página 133

216 GlossaryGAbbreviation for gravities.GBAbbreviation for gigabyte(s). A gigabyte equals 1,024 megabytes or 1,073,741,824 bytes.graphics coprocessorS

Página 134

Glossary 217host adapterA host adapter implements communication between the computer's bus and the controller for a peripheral device. (Hard driv

Página 135

22 Introduction

Página 136 - Commands

218 GlossaryIDAbbreviation for identification.iDRACAcronym for integrated Dell Remote Access Controller.IHVAcronym for independent hardware vendor. IH

Página 137

Glossary 219IRQAbbreviation for interrupt request. A signal that data is about to be sent to or received by a peripheral device travels by an IRQ line

Página 138

220 GlossaryKbit(s)Abbreviation for kilobit(s), 1,024 bits.Kbit(s)/secAbbreviation for kilobit(s) per second.KerberosA network authentication protocol

Página 139

Glossary 221LEDAbbreviation for light-emitting diode. An electronic device that lights up when a current is passed through it.local busOn a computer w

Página 140

222 GlossaryMbAbbreviation for megabit.MBAbbreviation for megabyte(s). The term megabyte means 1,048,576 bytes; however, when referring to hard drive

Página 141

Glossary 223MHzAbbreviation for megahertz.MIBAcronym for management information base. MIB is used to send detailed status/commands from or to an SNMP

Página 142

224 GlossaryMPEGAcronym for Motion Picture Experts Group. MPEG is a digital video file format.msAbbreviation for millisecond(s).MTBFAbbreviation for m

Página 143

Glossary 225noninterlacedA technique for decreasing screen flicker by sequentially refreshing each horizontal line on the screen.nsAbbreviation for na

Página 144 - ° Celsius

226 Glossaryparallel portAn I/O port used most often to connect a parallel printer to your computer. You can identify a parallel port on your computer

Página 145 - Complete Syntax

Glossary 227physical memory array mappedThe physical memory array mapped refers to the way physical memory is divided. For example, one mapped area ma

Página 146

Using the omhelp Command 21Using the omhelp CommandThe omhelp command and its equivalent, <command> -?, accesses the CLI's detailed help te

Página 147

228 Glossarypower unitA set of power supplies in a system chassis.ppmAbbreviation for pages per minute.PQFPAbbreviation for plastic quad flat pack, a

Página 148

Glossary 229PSAbbreviation for power supply.PS/2Abbreviation for Personal System/2.PXEAbbreviation for Pre-boot eXecution Environment.QFPAcronym for q

Página 149

230 GlossaryRDRAMAcronym for Rambus DRAM. A dynamic RAM chip technology from Rambus, Inc. Direct RDRAMs are used in computers. Direct RDRAM chips are

Página 150 - For SAS Controllers

Glossary 231RIMMAcronym for Rambus In-line Memory Module, which is the Rambus equivalent of a DIMM module. ROMAcronym for read-only memory. Your compu

Página 151 - RAID-6 raid=r6

232 GlossarysecAbbreviation for second(s).SECAbbreviation for single-edge contact.serial portAn I/O port used most often to connect a modem to your co

Página 152 - Table 6-18. Size Parameter

Glossary 233SIPAcronym for single in-line package, which is a type of housing for electronic components in which the connecting pins protrude from one

Página 153

234 Glossarystate Refers to the condition of an object that can have more than one condition. For example, an object may be in the “not ready” state.

Página 154

Glossary 235system configuration informationData stored in memory that instructs a computer what hardware is installed and how the computer should be

Página 155

236 Glossaryuse proprietary file formats containing binary characters, although some can read and write text files.text modeA video mode that can be d

Página 156

Glossary 237program, you can return to the other application program and leave the TSR program resident in memory for later use.TSR programs can somet

Página 157

22 Using the omhelp Command•shutdown• thrmshutdown• webserverFigure 2-1 shows the levels of help for a command.Figure 2-1. Different Levels of Help fo

Página 158

238 GlossaryutilityA program used to manage system resources—memory, disk drives, or printers, for example.UTPAbbreviation for unshielded twisted pair

Página 159

Glossary 239the number of colors that a program can display depends on the capabilities of the monitor, the video driver, and the amount of video memo

Página 160

240 Glossaryvideo resolutionVideo resolution—800 x 600, for example—is expressed as the number of pixels across by the number of pixels up and down. T

Página 161

Glossary 241WAbbreviation for watt(s).Wakeup on LANThe ability for the power in a client station to be turned on by the network. Remote wake-up enable

Página 162

242 GlossaryXMSAbbreviation for eXtended Memory Specification.ZIFAcronym for zero insertion force. Some computers use ZIF sockets and connectors to al

Página 163

Index 243IndexSymbols-?omconfig, 67omconfig chassis, 69omreport, 30request for help, 21Aaboutomconfig, 68acquisitioninformation, 114optional parameter

Página 164

244 Indexbiosomreport chassis, 34biossetupomconfig chassis, 69omreport chassis, 34blinkomconfig, 194blink physical diskomconfig, 173bmcomconfig chassi

Página 165

Index 245CLI commands?, 21primary commands, 14Windows command prompt, 14cmdlogomconfig system, 104omreport system, 51command levels 1,2, and 3omconfig

Página 166

246 IndexDdata bus widthomreport chassis slots, 49default maximum warning threshold, 77default minimum warning threshold, 77defining alert actions, 99

Página 167

Index 247Ffailure messages, 16fan statusomreport, 137fancontrolomconfig chassis, 78omreport chassis, 37fansomconfig chassis, 76omreport chassis, 37fir

Página 168

Using the omhelp Command 23For one info value, specify one or more optional parameter(s). Table 2-1 displays the optional parameters for info=acquisit

Página 169

248 IndexMmaintenance information, 119adding, 119manufactureromreport chassis processors, 43maximum speedomreport chassis ports, 43maximum warning thr

Página 170

Index 249prepare to remove physical disk, 175quiet controller alarm, 146rebuild physical disk, 180recondition battery, 185reconfiguring virtual disks,

Página 171

250 Indexomconfig chassis tempsname=value pairs, paramaters, 93omconfig chassis voltsname=value pairs, parameters, 95omconfig command, 63omconfig cont

Página 172

Index 251omconfig system recoveryname=value pairs, parameters, 110omconfig system shutdownname=value pairs, parameters, 111omconfig system warranty, 1

Página 173

252 Indexomreport chassis processorscache properties, 43connector name, 43core count, 43current speed, 43external clock speed, 43manufacturer, 43proce

Página 174

Index 253Physical disks in each stripe, 152platformeventsomconfig system, 104omreport system, 57port typeomreport chassis ports, 42portsomreport chass

Página 175

254 Indexset enclosure asset nameomconfig, 190set enclosure asset tagomconfig, 190set temperature probe thresholdsomconfig, 191-193shutdownomconfig sy

Página 176

Index 255unassign global hot spareomconfig, 180unblink physical diskomconfig, 174unmirroromconfig, 165user access to Server Administratoradministrator

Página 177

256 Index

Página 178

24 Using the omhelp Command

Página 179

omreport: Viewing System Status Using the Instrumentation Service 25omreport: Viewing System Status Using the Instrumentation ServiceThe omreport comm

Página 180

26 omreport: Viewing System Status Using the Instrumentation ServiceConventions for Parameter TablesWhen listing the parameters that a command can tak

Página 181

omreport: Viewing System Status Using the Instrumentation Service 27Table 3-2. Command Level 1, Level 2, and Level 3 for omreportCommand Level 1Comma

Página 182

Contents 3Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . 13What's New for Version 5.4 . . . . . . . . . . . . . . . 13Us

Página 183

28 omreport: Viewing System Status Using the Instrumentation Serviceinfo U, P, A Shows a status summary for main system chassis components.intrusion U

Página 184

omreport: Viewing System Status Using the Instrumentation Service 29alertaction U, P, A Shows warning and failure threshold values, as well as actions

Página 185

30 omreport: Viewing System Status Using the Instrumentation ServiceHelp With the omreport CommandUse the omreport -? command to get a list of the ava

Página 186

omreport: Viewing System Status Using the Instrumentation Service 31omreport aboutUse the omreport about command to learn the product name and version

Página 187

32 omreport: Viewing System Status Using the Instrumentation ServiceServer Administrator includes a number of services, each of which has a version nu

Página 188

omreport: Viewing System Status Using the Instrumentation Service 33omreport chassis acswitch/ omreport mainsystem acswitchUse the omreport chassis ac

Página 189

34 omreport: Viewing System Status Using the Instrumentation Serviceomreport chassis bios/omreport mainsystem biosUse the omreport chassis bios/omrepo

Página 190

omreport: Viewing System Status Using the Instrumentation Service 35Dual NIC Displays whether NIC 1 and NIC 2 with PXE/iSCSI is enabled or disabled.Ex

Página 191

36 omreport: Viewing System Status Using the Instrumentation Serviceomreport chassis bmc/omreport mainsystem bmcThis command is phased-out in this rel

Página 192

omreport: Viewing System Status Using the Instrumentation Service 37omreport chassis fans/omreport mainsystem fansUse the omreport chassis fans or omr

Página 193

4 Contentsomreport chassis/omreport mainsystem Commands. . . . . . . . . . . . . . . . . . . . . . . . 32omreport chassis/ omreport mainsystem . . .

Página 194

38 omreport: Viewing System Status Using the Instrumentation Serviceomreport chassis frontpanel/omreport mainsystem frontpanelUse the omreport chassis

Página 195 - ° Celsius, enter:

omreport: Viewing System Status Using the Instrumentation Service 39Depending on your configuration, output may resemble the following example:omrepor

Página 196

40 omreport: Viewing System Status Using the Instrumentation Serviceomreport chassis intrusionUse the omreport chassis intrusion command to find out w

Página 197

omreport: Viewing System Status Using the Instrumentation Service 41The index parameter is optional. If you do not specify the index, Server Administr

Página 198

42 omreport: Viewing System Status Using the Instrumentation Serviceomreport chassis nics/omreport mainsystem nicsUse the omreport chassis nics or omr

Página 199

omreport: Viewing System Status Using the Instrumentation Service 43Maximum Speed is the port speed. Port speed refers to the data transmission rate o

Página 200

44 omreport: Viewing System Status Using the Instrumentation ServiceThe following fields are defined for the capabilities present on a particular micr

Página 201 - List (lst)

omreport: Viewing System Status Using the Instrumentation Service 45cache that is accessed. The names L1 and L2 are not indicative of where the cache

Página 202 - Table (tbl)

46 omreport: Viewing System Status Using the Instrumentation ServiceCache Device Current Type is the type of the currently installed SRAM that the cac

Página 203 - Raw XML (xml)

omreport: Viewing System Status Using the Instrumentation Service 47omreport chassis pwrsupplies/omreport mainsystem pwrsuppliesUse the omreport chass

Página 204 - Custom Delimited Format (cdv)

Contents 5omreport chassis processors/omreport mainsystem processors . . . . . . . . . . . . . . 43omreport chassis pwrmonitoring/omreport mainsyste

Página 205 - Glossary

48 omreport: Viewing System Status Using the Instrumentation Serviceomreport chassis remoteaccess/omreport mainsystem remoteaccessUse the omreport cha

Página 206

omreport: Viewing System Status Using the Instrumentation Service 49The index parameter is optional. If you do not specify the index, Server Administr

Página 207 - Glossary 205

50 omreport: Viewing System Status Using the Instrumentation ServiceThe index parameter is optional. If you do not specify the index, Server Administr

Página 208

omreport: Viewing System Status Using the Instrumentation Service 51Commands for Viewing LogsYou can use the omreport system or omreport servermodule

Página 209 - Glossary 207

52 omreport: Viewing System Status Using the Instrumentation Serviceomreport system alertaction/omreport servermodule alertactionUse the omreport syst

Página 210

omreport: Viewing System Status Using the Instrumentation Service 53• Temperature Failure• Voltage Warning• Voltage Failure• Processor Warning• Proces

Página 211 - Glossary 209

54 omreport: Viewing System Status Using the Instrumentation Serviceomreport system events/omreport servermodule eventsUse the omreport system events

Página 212

omreport: Viewing System Status Using the Instrumentation Service 55To view the status for components of a specific type, use the omreport system even

Página 213 - Glossary 211

56 omreport: Viewing System Status Using the Instrumentation Serviceomreport system operatingsystem/omreport servermodule operatingsystemUse the omrep

Página 214

omreport: Viewing System Status Using the Instrumentation Service 57omreport system platformevents/omreport servermodule platformeventsUse the omrepor

Página 215 - Glossary 213

6 Contentsomreport system thrmshutdown/omreport servermodule thrmshutdown. . . . . . . . . . . . 61omreport system version/omreport servermodule ver

Página 216

58 omreport: Viewing System Status Using the Instrumentation Serviceomreport system summary/omreport servermodule summaryUse the omreport system summa

Página 217 - Glossary 215

omreport: Viewing System Status Using the Instrumentation Service 59The system summary hardware information includes data values for installed compone

Página 218

60 omreport: Viewing System Status Using the Instrumentation ServiceMemory• Total Installed Capacity• Memory Available to the Operating System• Total

Página 219 - Glossary 217

omreport: Viewing System Status Using the Instrumentation Service 61Network Interface Card The following details are listed for each NIC in the system

Página 220

62 omreport: Viewing System Status Using the Instrumentation ServiceExample Command OutputType:omreport system versionoromreport servermodule versionT

Página 221 - Glossary 219

omconfig: Managing Components Using the Instrumentation Service 63omconfig: Managing Components Using the Instrumentation ServiceThe omconfig command

Página 222

64 omconfig: Managing Components Using the Instrumentation ServiceConventions for Parameter TablesWhen listing the parameters that a command can take,

Página 223 - Glossary 221

omconfig: Managing Components Using the Instrumentation Service 65dirservice A Configures the Microsoft Active Directory® service.snmp A Sets the SNMP

Página 224

66 omconfig: Managing Components Using the Instrumentation Servicethrmshutdown A Sets the severity level at which a thermal event triggers a system sh

Página 225 - Glossary 223

omconfig: Managing Components Using the Instrumentation Service 67Help With the omconfig CommandUse the omconfig -? command to get a list of the avail

Página 226

Contents 7omconfig chassis temps/omconfig mainsystem temps. . . . . . . . . . . . . . . . . 93omconfig chassis volts/omconfig mainsystem volts. . .

Página 227 - Glossary 225

68 omconfig: Managing Components Using the Instrumentation ServiceUse a command of the form omconfig system <command level 3> -? to get a list o

Página 228

omconfig: Managing Components Using the Instrumentation Service 69Server Administrator includes a number of services, each of which has a version numb

Página 229 - Glossary 227

70 omconfig: Managing Components Using the Instrumentation ServiceTable 4-3 shows the name=value pairs you can use with this command.Table 4-3. BIOS S

Página 230

omconfig: Managing Components Using the Instrumentation Service 71attribute=dualnic setting=off | onpxeboth | onpxenone | onpxenic1 | onpxenic2off: Di

Página 231 - Glossary 229

72 omconfig: Managing Components Using the Instrumentation Serviceattribute=intusb setting=enabled | disabledenabled: Enables the internal USB drive.d

Página 232

omconfig: Managing Components Using the Instrumentation Service 73attribute=nic3 setting=enabled | enabledwithpxe | disabled | enabledonly | enabledno

Página 233 - Glossary 231

74 omconfig: Managing Components Using the Instrumentation Serviceattribute=ppaddress setting=off | lpt1 | lpt2 | lpt3off: Disables the parallel port

Página 234

omconfig: Managing Components Using the Instrumentation Service 75attribute=sata setting=off | ata | raid off: Disables the SATA controller.ata: Sets

Página 235 - Glossary 233

76 omconfig: Managing Components Using the Instrumentation Serviceomconfig chassis bmc/omconfig mainsystem bmc NOTE: This command is phased-out in th

Página 236 - • Various ROM chips

omconfig: Managing Components Using the Instrumentation Service 77Valid Parameters for Fan Warning ThresholdsTable 4-4 shows the valid parameters for

Página 237 - Glossary 235

8 ContentsAdding Acquisition Information . . . . . . . . . . . . . 114Example Commands for Adding Acquisition Information. . . . . . . . . . . . . .

Página 238

78 omconfig: Managing Components Using the Instrumentation Serviceomconfig chassis fans index=0 minwarnthresh=4580 maxwarnthresh=9160oromconfig mainsy

Página 239 - Glossary 237

omconfig: Managing Components Using the Instrumentation Service 79Table 4-6 shows the valid parameters for the command.omconfig chassis info/omconfig

Página 240

80 omconfig: Managing Components Using the Instrumentation ServiceIndex 0 always defaults to the main system chassis. The following command omits inde

Página 241 - VGA feature connector

omconfig: Managing Components Using the Instrumentation Service 81omconfig chassis memorymode/omconfig mainsystem memorymodeUse the omconfig chassis m

Página 242

82 omconfig: Managing Components Using the Instrumentation ServiceTable 4-9 shows the valid parameters for the command.omconfig chassis pwrmonitoring/

Página 243 - Glossary 241

omconfig: Managing Components Using the Instrumentation Service 83Default Warning Thresholds NOTE: The capabilities for managing sensors vary by syst

Página 244

84 omconfig: Managing Components Using the Instrumentation Service• The BMC or RAC on a serial over LAN connection.• Terminal settings for the serial

Página 245 - Index 243

omconfig: Managing Components Using the Instrumentation Service 85enablenic=true | false true: Enables DRAC NIC.false: Disables DRAC NICNOTE: The ena

Página 246

86 omconfig: Managing Components Using the Instrumentation Serviceconfig=nic (continued)vlanenable=true | false true: Enables the virtual LAN identifi

Página 247 - Index 245

omconfig: Managing Components Using the Instrumentation Service 87config=serial (continued)mode=directbasic | directterminal | directbasicterminal | m

Página 248

Contents 9Adding Warranty Information . . . . . . . . . . . . . . 127Example Command for Adding Warranty Information. . . . . . . . . . . . . . . . .

Página 249 - Index 247

88 omconfig: Managing Components Using the Instrumentation Serviceconfig=serialoverlan enable=true | false true: Enables serial over LAN for the BMC.

Página 250

omconfig: Managing Components Using the Instrumentation Service 89config=terminalmode (continued)echocontrol=enabled | disabledenabled: Enables charac

Página 251 - Index 249

90 omconfig: Managing Components Using the Instrumentation Serviceconfig=user id=number enable=true | falseid=number: ID (in numeric format) of the us

Página 252

omconfig: Managing Components Using the Instrumentation Service 91config=user (continued)id=number lanaccesslevel=administrator | operator | user| non

Página 253 - Index 251

92 omconfig: Managing Components Using the Instrumentation Serviceid=user id extimpiusergroup=admin | poweruser | custom | noneNOTE: extimpiusergroup

Página 254

omconfig: Managing Components Using the Instrumentation Service 93omconfig chassis temps/omconfig mainsystem tempsUse the omconfig chassis temps or om

Página 255 - Index 253

94 omconfig: Managing Components Using the Instrumentation ServiceSetting Minimum and Maximum Warning Threshold ValuesIf you want to set both the uppe

Página 256

omconfig: Managing Components Using the Instrumentation Service 95Valid Parameters for Voltage Warning ThresholdsTable 4-15 shows the valid parameters

Página 257 - Index 255

96 omconfig: Managing Components Using the Instrumentation ServiceWhen you issue the command and the system sets the values you specify, the following

Página 258 - 256 Index

omconfig: Managing Components Using the Instrumentation Service 97Therefore, for a computer named "myOmsa" running Server Administrator, the

Comentários a estes Manuais

Sem comentários