Dell OpenManage Server Administrator Version 5.4 Guia do Utilizador Página 645

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 732
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 644
Traps 645
Table 25-6. Amperage Probe Traps
Trap ID Description Severity Cause
Amperage Probe Normal
1202 Current sensor returned to
a normal value
Sensor location:
<Location in chassis>
Chassis location: <Name of
chassis>
Previous state was:
<State>
If sensor type is not
discrete: Current sensor
value (in Amps): <Reading>
If sensor type is
discrete: Discrete current
state: <State>
Information A current sensor on the
power supply for the
specified system
returned to a valid range
after crossing a failure
threshold. The sensor
location, chassis
location, previous state,
and current sensor value
are provided.
Amperage Probe Warning
1203 Current sensor detected a
warning value
Sensor location:
<Location in chassis>
Chassis location: <Name of
chassis>
Previous state was:
<State>
If sensor type is not
discrete: Current sensor
value (in Amps): <Reading>
If sensor type is
discrete: Discrete current
state: <State>
Warning A current sensor on the
power supply for the
specified system
exceeded its warning
threshold. The sensor
location, chassis
location, previous state,
and current sensor value
are provided.
Vista de página 644
1 2 ... 640 641 642 643 644 645 646 647 648 649 650 ... 731 732

Comentários a estes Manuais

Sem comentários