Resumo do Conteúdo

Página 1 - Owner’s Manual

Dell PowerVault MD3200iand MD3220i Storage ArraysOwner’s ManualRegulatory Model: E03J Series and E04J SeriesRegulatory Type: E03J001 and E04J001book.b

Página 2 - Notes, Cautions, and Warnings

10 ContentsChanging the RAID Level of a Disk Group . . . . . . . 139Storage Partitioning . . . . . . . . . . . . . . . . . . 140Disk Group and Vir

Página 3 - Contents

100 Configuration: About Your Host4Click Yes.The host is moved to the selected host group with the following mappings:• The host retains the specific

Página 4 - 4 Contents

Configuration: About Your Host 101• Changing a host type MDSM automatically detects these changes for any host running the host agent software.Startin

Página 5

102 Configuration: About Your Host4Click Action Start. I/O Data Path ProtectionYou can have multiple host-to-array connections for a host. Ensure tha

Página 6 - 6 Configuration: About Your

Configuration: About Your Host 103Managing Host Port IdentifiersYou can manage the host port identifiers that are added to the storage array. You can:

Página 7

104 Configuration: About Your Host•Add by creating a new host port identifier—In New host port identifier, enter the name of the new host port identif

Página 8 - 8 Contents

Configuration: Disk Groups and Virtual Disks 10510Configuration: Disk Groups and Virtual DisksCreating Disk Groups and Virtual DisksDisk groups are cr

Página 9

106 Configuration: Disk Groups and Virtual DisksA disk group must be organized according to its related tasks and subtasks. For example, if you create

Página 10 - 11 Configuration: Premium

Configuration: Disk Groups and Virtual Disks 1073Type the name of the disk group (up to 30 characters) in Disk group name.4Select the appropriate Phys

Página 11 - Feature—Virtual Disk Copy

108 Configuration: Disk Groups and Virtual DisksLocating a Disk GroupYou can physically locate and identify all of the physical disks that comprise a

Página 12 - 12 Contents

Configuration: Disk Groups and Virtual Disks 109 NOTE: Ensure that you create disk groups before creating virtual disks.To create virtual disks:1Choo

Página 13

Contents 11Preparing Host Servers to Create the Snapshot Using the Simple Path. . . . . . . . . . 153Creating a Snapshot Virtual Disk Using the Advan

Página 14 - 14 Contents

110 Configuration: Disk Groups and Virtual Disks•Use recommended settings.•Customize settings.6Click Next.7In the Customize Advanced Virtual Disk Para

Página 15

Configuration: Disk Groups and Virtual Disks 1112Select a virtual disk.3In the toolbar, select Virtual Disk Change Modification Priority.The Change

Página 16 - 16 Contents

112 Configuration: Disk Groups and Virtual Disks2In the toolbar, select Virtual Disk Change Cache Settings.The Change Cache Settings window is displ

Página 17

Configuration: Disk Groups and Virtual Disks 1137Click OK.Changing the Segment Size of a Virtual DiskYou can change the segment size on a selected vir

Página 18 - 18 Contents

114 Configuration: Disk Groups and Virtual DisksThe segment size modification operation begins. The virtual disk icon in the Logical pane shows an Ope

Página 19 - Introduction

Configuration: Disk Groups and Virtual Disks 115 NOTE: If you selected the Custom option, select your preferred dynamic cache read prefetch setting (

Página 20 - Series Storage Array

116 Configuration: Disk Groups and Virtual DisksWhenever the power is turned off and turned on again, all of the security-enabled physical disks chang

Página 21 - Introduction 21

Configuration: Disk Groups and Virtual Disks 117 NOTE: If you have not created a security key for the storage array, the Create Security Key option i

Página 22 - 22 Introduction

118 Configuration: Disk Groups and Virtual DisksCreating a Security KeyWhen you create a security key, it is generated by and securely stored by the a

Página 23 - Overview

Configuration: Disk Groups and Virtual Disks 119The pass phrase that you enter is masked.NOTE: Create Key is active only if the pass phrase meets the

Página 24 - Hardware Features

12 ContentsOnline Copy . . . . . . . . . . . . . . . . . . . . 175Creating a Virtual Disk Copy for an MSCS Shared Disk. . . . . . . . . . . . . . .

Página 25

120 Configuration: Disk Groups and Virtual DisksTo change the security key:1In the AMW toolbar, select Storage ArrayPhysical Disk Security Change S

Página 26

Configuration: Disk Groups and Virtual Disks 121Saving a Security KeyYou save an externally storable copy of the security key when the security key is

Página 27

122 Configuration: Disk Groups and Virtual DisksValidate Security KeyA file in which a security key is stored is validated through the Val id at e Sec

Página 28 - Hard-Drive Indicator Patterns

Configuration: Disk Groups and Virtual Disks 123Before you complete this option, make sure that the physical disk that you have selected is the correc

Página 29

124 Configuration: Disk Groups and Virtual DisksTo assign or unassign hot spare physical disks:1In the AMW, select the Physical tab.2Select one or mor

Página 30

Configuration: Disk Groups and Virtual Disks 12512Ty p e yes and click OK.Hot Spares and Rebuild A valuable strategy to protect data is to assign ava

Página 31 - RAID Controller Modules

126 Configuration: Disk Groups and Virtual DisksHot Spare Drive ProtectionYou can use a hot spare physical disk for additional data protection from ph

Página 32

Configuration: Disk Groups and Virtual Disks 127 CAUTION: Enclosure loss protection is not guaranteed if a physical disk has already failed in the di

Página 33

128 Configuration: Disk Groups and Virtual DisksHost-to-Virtual Disk MappingAfter you create virtual disks, you must map them to the host(s) connected

Página 34 - Battery Backup Unit

Configuration: Disk Groups and Virtual Disks 129• Each host has its own LUN address space. MDSM permits the same LUN to be used by different hosts or

Página 35 - Cache Functions and Features

Contents 1313 Configuration: Premium Feature—Upgrading to High-Performance-Tier . . . . . . . . . . . . . 18714 Configuration: Device Mapper Multipat

Página 36 - Write-Through Cache

130 Configuration: Disk Groups and Virtual DisksAll defined hosts, host groups, and the default group is displayed in the list. NOTE: When configuri

Página 37 - Array Terms and Concepts

Configuration: Disk Groups and Virtual Disks 131• Right-click the virtual disk, and select Change Mapping from the pop-up menu.3In Host group or host,

Página 38 - Physical Disk States

132 Configuration: Disk Groups and Virtual DisksDuring a virtual disk copy, the same RAID controller module must own both the source virtual disk and

Página 39 - Virtual Disks and Disk Groups

Configuration: Disk Groups and Virtual Disks 133associated source virtual disk. Changing the RAID controller module ownership of a virtual disk change

Página 40 - RAID Levels

134 Configuration: Disk Groups and Virtual Disks• The disk group must be in Optimal status before you can perform this operation.• Your data remains a

Página 41 - RAID Level Usage

Configuration: Disk Groups and Virtual Disks 135In this example, the mpath6 device contains two paths:-- /dev/sdf at Host 1, Channel 0, Target 0, LUN

Página 42 - Segment Size

136 Configuration: Disk Groups and Virtual DisksRestricted MappingsMany hosts are able to map up to 256 logical unit numbers (LUNs) (0 to 255) per sto

Página 43 - Virtual Disk Operations

Configuration: Disk Groups and Virtual Disks 137• You cannot move a host with a restricted host type into a storage partition that already has LUNs ma

Página 44 - Cycle Time

138 Configuration: Disk Groups and Virtual DisksaChange the RAID controller module ownership of a virtual disk—Go to step 2.bChange the RAID controlle

Página 45 - Disk Group Operations

Configuration: Disk Groups and Virtual Disks 139eClick Yes.The ownership of the disk group is changed. I/O to the disk group is now directed through t

Página 46 - Disk Group Defragmentation

14 ContentsMedia Errors and Unreadable Sectors . . . . . . . . 21016 Management: Installing Array Components . . . . . . . . . . . . . . . . . . .

Página 47 - Disk Group Operations Limit

140 Configuration: Disk Groups and Virtual DisksStorage PartitioningA storage partition is a logical entity consisting of one or more virtual disks th

Página 48 - Disk Migration

Configuration: Disk Groups and Virtual Disks 141 NOTE: You can include a secondary virtual disk in a storage partition. However, any hosts that are m

Página 49

142 Configuration: Disk Groups and Virtual Disks5Click Add.A message prompts you to confirm your selection.6To add the capacity to the disk group, cli

Página 50 - Advanced Features

Configuration: Disk Groups and Virtual Disks 143For more information, see the PowerVault Modular Disk Storage Manager online help topics.Disk Group Mi

Página 51 - Host Types

144 Configuration: Disk Groups and Virtual Disks2Stop all I/O and unmount or disconnect the file systems on the virtual disks in the disk group. 3Back

Página 52

Configuration: Disk Groups and Virtual Disks 145 NOTE: Some settings cannot be imported during the import disk group procedure.The following settings

Página 53

146 Configuration: Disk Groups and Virtual Disks• Recovered media error—Data could not be read by the physical disk on the first attempt but was succe

Página 54 - Multi-Path Software

Configuration: Disk Groups and Virtual Disks 1478Click OK.Suspending the Media ScanYou cannot perform a media scan while performing another long-runni

Página 55 - Virtual Disk Ownership

148 Configuration: Disk Groups and Virtual Disksbook.book Page 148 Saturday, September 24, 2011 9:06 AM

Página 56 - Load Balancing

Configuration: Premium Feature—Snapshot Virtual Disks 14911Configuration: Premium Feature—Snapshot Virtual Disks NOTE: If you ordered this feature, y

Página 57

Contents 15Power Supply/Cooling Fan Module . . . . . . . . . . . 225Removing a Power Supply/Cooling Fan Module. . . . . . . . . . . . . . . . . . . .

Página 58

150 Configuration: Premium Feature—Snapshot Virtual Disksrepository uses less disk space than a full physical copy, because the only data blocks that

Página 59

Configuration: Premium Feature—Snapshot Virtual Disks 151To implement this backup, select the first virtual disk and create a backup schedule that run

Página 60

152 Configuration: Premium Feature—Snapshot Virtual DisksEnabling and Disabling Snapshot SchedulesA scheduled snapshot operation can be temporarily su

Página 61 - Configuration: Overview

Configuration: Premium Feature—Snapshot Virtual Disks 153About the Simple PathUsing the simple path, you can specify:• Snapshot Virtual Disk Name—A us

Página 62 - Enterprise Management Window

154 Configuration: Premium Feature—Snapshot Virtual Disks NOTE: Mapping the snapshot virtual disk to the node that does not own the source virtual di

Página 63 - Array Management Window

Configuration: Premium Feature—Snapshot Virtual Disks 1552In the AMW, select the Logical tab and select a valid source virtual disk.3Select Virtual Di

Página 64

156 Configuration: Premium Feature—Snapshot Virtual Disks13To associate the mapping between the storage array name and the virtual disk name, run the

Página 65 - Out-of-Band Management

Configuration: Premium Feature—Snapshot Virtual Disks 157– Dell recommends placing the snapshot repository virtual disk within the disk group of the s

Página 66 - Storage Arrays

158 Configuration: Premium Feature—Snapshot Virtual DisksThe destination of a snapshot repository virtual disk is determined based on the free capacit

Página 67

Configuration: Premium Feature—Snapshot Virtual Disks 1592Using your Windows system, flush the cache to the source. At the host prompt, type SMrepassi

Página 68 - Setting Up Your Storage Array

16 ContentsCollecting the Physical Disk Data . . . . . . . . . . . 244Event Log. . . . . . . . . . . . . . . . . . . . . . . . 244Recovery Guru .

Página 69 - Locating Storage Arrays

160 Configuration: Premium Feature—Snapshot Virtual Disks3Select Virtual Disk Snapshot Create. Alternatively, you can right-click the source virtual

Página 70

Configuration: Premium Feature—Snapshot Virtual Disks 16112Click OK.13In the Mappings tab, assign mappings between the snapshot virtual disk and the h

Página 71 - Setting a Password

162 Configuration: Premium Feature—Snapshot Virtual Disks• The next available sequence number is based on the number of existing snapshots of a source

Página 72 - Password Guidelines

Configuration: Premium Feature—Snapshot Virtual Disks 163 NOTE: You can add a maximum of two physical disks at one time to increase snapshot reposito

Página 73 - Removing Storage Arrays

164 Configuration: Premium Feature—Snapshot Virtual Disks7If unassigned physical disks are not available, do you have empty slots in the expansion enc

Página 74 - Failover Alert Display

Configuration: Premium Feature—Snapshot Virtual Disks 165• Not all of the capacity that is added is used to increase the capacity of the snapshot repo

Página 75

166 Configuration: Premium Feature—Snapshot Virtual DisksPreparing Host Servers to Re-create a Snapshot Virtual Disk NOTE: Before you create a new sn

Página 76 - Configuring E-mail Alerts

Configuration: Premium Feature—Snapshot Virtual Disks 167Re-creating Snapshot Virtual DisksYou can re-create a snapshot virtual disk that you have pre

Página 77

168 Configuration: Premium Feature—Snapshot Virtual DisksThe associated snapshot repository virtual disk must have sufficient capacity to process the

Página 78

Configuration: Premium Feature—Snapshot Virtual Disks 169If an error occurs during the rollback, the operation is paused and the base virtual disk and

Página 79 - Configuring SNMP Alerts

Contents 17Troubleshooting Loss of Communication . . . . . . . . 263Troubleshooting External Connections . . . . . . . . . 263Troubleshooting Power

Página 80 - Battery Settings

170 Configuration: Premium Feature—Snapshot Virtual Disks2Choose one:• Select the snapshot virtual disk, and select Virtual Disk SnapshotRollback.•

Página 81

Configuration: Premium Feature—Snapshot Virtual Disks 171Canceling a Snapshot Rollback WARNING: Risk of data loss: If you cancel a snapshot rollback

Página 82

172 Configuration: Premium Feature—Snapshot Virtual Disksbook.book Page 172 Saturday, September 24, 2011 9:06 AM

Página 83 - Configuration: Using iSCSI

Configuration: Premium Feature—Virtual Disk Copy 17312Configuration: Premium Feature—Virtual Disk Copy NOTE: A virtual disk copy overwrites data on t

Página 84 - Creating CHAP Secrets

174 Configuration: Premium Feature—Virtual Disk Copy• Copying data for improved access—As your storage requirements for a virtual disk change, you can

Página 85 - Target CHAP Secret

Configuration: Premium Feature—Virtual Disk Copy 175the source virtual disk may be rejected by the storage array RAID controller modules and result in

Página 86

176 Configuration: Premium Feature—Virtual Disk CopyCreating a Virtual Disk Copy for an MSCS Shared DiskTo create a virtual disk copy for a Microsoft

Página 87

Configuration: Premium Feature—Virtual Disk Copy 177• To enable Read-Only permission, select Change Tar get Virt ua l D isk Permissions Enable Rea

Página 88

178 Configuration: Premium Feature—Virtual Disk CopyCreating a Virtual Disk Copy CAUTION: Possible loss of data – Source virtual disks that are parti

Página 89

Configuration: Premium Feature—Virtual Disk Copy 179Virtual Disk Copy and Modification OperationsIf a modification operation is running on a source vi

Página 90

18 Contentsbook.book Page 18 Saturday, September 24, 2011 9:06 AM

Página 91 - Statistics

180 Configuration: Premium Feature—Virtual Disk CopyPreferred RAID Controller Module OwnershipDuring a virtual disk copy, the same RAID controller mod

Página 92 - 92 Configuration: Using iSCSI

Configuration: Premium Feature—Virtual Disk Copy 181A virtual disk copy automatically makes the target virtual disk read-only to hosts. You may want t

Página 93 - Configuration: Event Monitor

182 Configuration: Premium Feature—Virtual Disk Copy9Ty p e yes and click Finish. NOTE: Operation in Progress icons are displayed on the source virt

Página 94

Configuration: Premium Feature—Virtual Disk Copy 1832In the table, select one or more copy pairs.3Select Change Copy Priority.The Change Copy Priorit

Página 95 - Configuring Host Access

184 Configuration: Premium Feature—Virtual Disk CopyPreparing Host Servers to Recopy a Virtual Disk NOTE: Before you create a new copy of a source vi

Página 96 - Using the Mappings Tab

Configuration: Premium Feature—Virtual Disk Copy 185Re-Copying a Virtual DiskYou can use the Copy Manager to create a new virtual disk copy for a sele

Página 97

186 Configuration: Premium Feature—Virtual Disk CopyRemoving Copy PairsYou can remove one or more virtual disk copies by using the Copy Manager. Any v

Página 98 - Managing Host Groups

Configuration: Premium Feature—Upgrading to High-Performance-Tier 18713Configuration: Premium Feature—Upgrading to High-Performance-Tier The High Perf

Página 99 - Adding a Host to a Host Group

188 Configuration: Premium Feature—Upgrading to High-Performance-Tierbook.book Page 188 Saturday, September 24, 2011 9:06 AM

Página 100 - Host Topology

Configuration: Device Mapper Multipath for Linux 18914Configuration: Device Mapper Multipath for LinuxOverviewThe MD3200i Series storage array uses a

Página 101

Introduction 191Introduction NOTE: Unless specified, MD3200i Series represents Dell PowerVault MD3200i and Dell PowerVault MD3220i storage arrays. WA

Página 102 - I/O Data Path Protection

190 Configuration: Device Mapper Multipath for LinuxUsing DM Multipathing Devices NOTE: Using or modifying any nodes other than the multipathing devi

Página 103

Configuration: Device Mapper Multipath for Linux 191 NOTE: Any arrays configured with MDCU automatically adds to the list of Devices in the PowerVaul

Página 104

192 Configuration: Device Mapper Multipath for LinuxDisplay the multipath device topology using the multipath commandThe multipath command adds newly

Página 105 - Virtual Disks

Configuration: Device Mapper Multipath for Linux 193\_ round-robin 0 [prio=1][enabled] \_ 6:0:0:22 sdcl 69:144 [active][ghost]where:mpathb is the name

Página 106 - Creating Disk Groups

194 Configuration: Device Mapper Multipath for Linux# lsThe following are some examples of the general mapping formats:On RHEL hosts ,a partition node

Página 107

Configuration: Device Mapper Multipath for Linux 195Blacklist Local Drive in Multi-path DriverIf your multipath drivers are connecting to storage area

Página 108 - Creating Virtual Disks

196 Configuration: Device Mapper Multipath for Linux2Stop the Device Mapper multipath service # /etc/init.d/multipathd stop3Flush the Device Mapper mu

Página 109

Configuration: Device Mapper Multipath for Linux 197Limitations and Known Issues• In certain error conditions with the no_path_retry or the queue_if_n

Página 110

198 Configuration: Device Mapper Multipath for Linux• After a failed path is restored on an MD3600i Series array, failback does not occur automaticall

Página 111

Configuration: Device Mapper Multipath for Linux 199I removed a LUN. But the multipathing mapping is still there.The multipathing device is still ther

Página 112

Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indica

Página 113

20 Introduction• Mounting rails (2) (optional)• MD3200i Series resource media •Rack Installation Instructions. •Getting Started With Your System (prov

Página 114 - Changing the I/O Type

200 Configuration: Device Mapper Multipath for Linuxbook.book Page 200 Saturday, September 24, 2011 9:06 AM

Página 115

Management: Firmware Downloads 20115Management: Firmware DownloadsDownloading RAID Controller and NVSRAM PackagesA version number exists for each firm

Página 116

202 Management: Firmware DownloadsDownloading Both RAID Controller and NVSRAM Firmware NOTE: I/O to the array can continue while you are upgrading RA

Página 117

Management: Firmware Downloads 2037Click Transfer.Keep these guidelines in mind:–If the Transfer button is inactive, ensure that you either select an

Página 118 - Creating a Security Key

204 Management: Firmware DownloadsThe Select File dialog is displayed.13Select the file to download.14Click OK.15If you want to download the NVSRAM fi

Página 119 - Changing a Security Key

Management: Firmware Downloads 2052Select Advanced Maintenance Download RAID Controller Module NVSRAM orSelect the Support tab, and click Download

Página 120

206 Management: Firmware Downloads NOTE: The Details pane shows the details of only one storage array at a time. If you select more than one storage

Página 121 - Saving a Security Key

Management: Firmware Downloads 207disk called DACstore. DACstore and the physical disk firmware enable easier reconfiguration and migration of the phy

Página 122 - Erasing Secure Physical Disks

208 Management: Firmware Downloads4Navigate to the location of the packages and click OK.The selected package is added to the Packages to be transferr

Página 123

Management: Firmware Downloads 209•In the AMW, select Advanced Maintenance Download EMM Firmware.• Select the Support tab, and click Download Firmw

Página 124

Introduction 21•The Deployment Guide provides installation and configuration instructions for both software and hardware. •The Storage Manager CLI Gui

Página 125 - Hot Spare Operation

210 Management: Firmware Downloads• The download failed—The status of one expansion enclosure shows Failed and the remainder of the expansion enclosur

Página 126 - Enclosure Loss Protection

Management: Installing Array Components 21116Management: Installing Array ComponentsRecommended ToolsYou may need the following items to perform the p

Página 127

212 Management: Installing Array ComponentsFront Bezel (Optional)Removing the Front Bezel1Using the system key, unlock the front bezel (if locked).2Li

Página 128 - Host-to-Virtual Disk Mapping

Management: Installing Array Components 213Hard DrivesSAFETY: Models AMT, E03J, and E04JModels AMT, E03J, and E04J are intended for installation only

Página 129

214 Management: Installing Array ComponentsFigure 16-3. Removing and Installing a 2.5" Hard-Drive Blank (MD3220i Only)Installing a Hard-Drive Bla

Página 130

Management: Installing Array Components 2152From the Modular Disk Storage Manager (MDSM) software, prepare the drive for removal. Wait until the hard-

Página 131

216 Management: Installing Array ComponentsInstalling a Hard Drive CAUTION: Many repairs may only be done by a certified service technician. You must

Página 132

Management: Installing Array Components 217Figure 16-5. Removing and Installing a Hard Drive Into a 3.5" Hard-Drive Carrier1 screws (4) 2 hard d

Página 133

218 Management: Installing Array ComponentsFigure 16-6. Removing and Installing a Hard Drive Into a 2.5" Hard-Drive Carrier1 screws (4) 2 hard d

Página 134

Management: Installing Array Components 219Installing a Hard Drive Into a Hard-Drive Carrier1 Insert the hard drive into the hard-drive carrier with t

Página 135

22 Introductionbook.book Page 22 Saturday, September 24, 2011 9:06 AM

Página 136 - Restricted Mappings

220 Management: Installing Array Components5Connect all the power cables to the array.6Turn on the array and the host server.Figure 16-7. Removing and

Página 137 - Disk Group

Management: Installing Array Components 221Removing a RAID Controller Module CAUTION: Many repairs may only be done by a certified service technicia

Página 138

222 Management: Installing Array ComponentsInstalling a RAID Controller Module CAUTION: Many repairs may only be done by a certified service technic

Página 139

Management: Installing Array Components 223Figure 16-9. Opening and Closing the RAID Controller ModuleClosing the RAID Controller Module CAUTION: Man

Página 140 - Storage Partitioning

224 Management: Installing Array ComponentsRAID Controller Module Backup Battery Unit Removing the RAID Controller Module Backup Battery Unit CAUTIO

Página 141 - Disk Group Expansion

Management: Installing Array Components 225Installing the RAID Controller Module Backup Battery Unit CAUTION: Many repairs may only be done by a cert

Página 142 - Using Unconfigured Capacity

226 Management: Installing Array Componentssupport team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read

Página 143 - Disk Group Migration

Management: Installing Array Components 227Figure 16-11. Removing and Installing a Power Supply/Cooling Fan Module1 release tab 2 power supply3 power

Página 144 - Import Disk Group

228 Management: Installing Array ComponentsInstalling a Power Supply/Cooling Fan Module CAUTION: Many repairs may only be done by a certified service

Página 145 - Storage Array Media Scan

Management: Installing Array Components 229Control PanelRemoving the Control Panel1Turn off the array and host server.2Disconnect all the power cables

Página 146 - Changing Media Scan Settings

Planning: About Your Storage Array 232Planning: About Your Storage ArrayOverviewThe MD3200i Series storage array is designed for high availability, of

Página 147 - Suspending the Media Scan

230 Management: Installing Array ComponentsFigure 16-14. Removing and Installing the Control Panel-PowerVault MD3220iInstalling the Control Panel1Alig

Página 148

Management: Installing Array Components 231Backplane CAUTION: Many repairs may only be done by a certified service technician. You must only perform

Página 149 - Snapshot Virtual Disks

232 Management: Installing Array ComponentsFigure 16-15. Removing and Installing the RAID Controller Module/Power Supply Cage1 screws (6) 2 RAID cont

Página 150

Management: Installing Array Components 233Figure 16-16. Removing and Installing the Backplane-PowerVault MD3200iFigure 16-17. Removing and Installing

Página 151

234 Management: Installing Array ComponentsInstalling the Backplane1Align the holes on the backplane with the holes on the array.2Tighten the captive

Página 152 - Simple Path

Management: Firmware Inventory 23517Management: Firmware InventoryA storage array is made up of many components, which may include RAID controller mod

Página 153 - About the Simple Path

236 Management: Firmware Inventorybook.book Page 236 Saturday, September 24, 2011 9:06 AM

Página 154

Management: System Interfaces 23718Management: System InterfacesMicrosoft ServicesVirtual Disk ServiceThe Microsoft Virtual Disk Service (VDS) is a co

Página 155

238 Management: System InterfacesVSS attaches to the service and uses it to coordinate the creation of snapshot virtual disks on the storage array. VS

Página 156 - Advanced Path

Troubleshooting: Your Storage Array Software 23919Troubleshooting: Your Storage Array SoftwareStart-Up Routine Look and listen during the array’s star

Página 157

24 Planning: About Your Storage ArrayHardware FeaturesFront-Panel Features and Indicators Figure 2-1. Front-Panel Features and Indicators—Dell PowerVa

Página 158

240 Troubleshooting: Your Storage Array Software•On the Devices tab, in either the Tree view or the Table view, double-click a storage array. Alternat

Página 159

Troubleshooting: Your Storage Array Software 241In the Table view, every managed storage array is listed once, regardless of the number of attachments

Página 160

242 Troubleshooting: Your Storage Array Software NOTE: MDSM may take a few minutes to update a status change to Unresponsive or from Unresponsive. A

Página 161

Troubleshooting: Your Storage Array Software 2432Enter a name for the support data file in Specify filename or click Browse to navigate to a previousl

Página 162 - Snapshot Repository Capacity

244 Troubleshooting: Your Storage Array SoftwareCollecting the Physical Disk DataYou can use the Collect Physical Disk Data option to collect log sens

Página 163 - Capacity option is disabled

Troubleshooting: Your Storage Array Software 245The event log window shows two types of event views:• Summary view—Shows an event summary in a table f

Página 164

246 Troubleshooting: Your Storage Array Software• Alert notification messages that are sent to the appropriate destinations • Hardware indicator light

Página 165

Troubleshooting: Your Storage Array Software 247bType the term that you want to search for in the Find text box.If the term is located on the current

Página 166

248 Troubleshooting: Your Storage Array Software2Select View Associated Logical Elements. Alternatively, you can right-click the virtual disk to open

Página 167 - Snapshot Rollback

Troubleshooting: Your Storage Array Software 249• The node name and the RAID level• The node name and the virtual disk capacityTo find nodes:1In the A

Página 168

Planning: About Your Storage Array 25Figure 2-3. Front-Bezel Features and IndicatorsItem Indicator, Button, or ConnectorIcon Description1 Enclosure st

Página 169 - Starting a Snapshot Rollback

250 Troubleshooting: Your Storage Array SoftwarebType the capacity in the GB box.cSpecify that the free capacity to be matched is less than, equal to,

Página 170 - Resuming a Snapshot Rollback

Troubleshooting: Your Storage Array Software 2514Select View Go To Source Virtual Disk.The selection jumps to the associated source virtual disk in

Página 171 - Canceling a Snapshot Rollback

252 Troubleshooting: Your Storage Array Software• ping <host-name>• ping <RAID controller module-IP-address>7If the verification is succes

Página 172

Troubleshooting: Your Storage Array Software 25319If you have recently replaced or added the RAID controller module, restart the host context agent so

Página 173 - Virtual Disk Copy

254 Troubleshooting: Your Storage Array SoftwareTo locate the physical disk:1Select the Physical tab.2Select the physical disks that you want to locat

Página 174 - Types of Virtual Disk Copies

Troubleshooting: Your Storage Array Software 255Locating an Expansion EnclosureYou can use the Blink option to physically locate and identify an expan

Página 175 - Online Copy

256 Troubleshooting: Your Storage Array SoftwareCapturing the State InformationUse the Troubleshooting Capture State Information option to capture in

Página 176

Troubleshooting: Your Storage Array Software 257SMrepassist UtilitySMrepassist (replication assistance) is a host-based utility for Windows platforms.

Página 177

258 Troubleshooting: Your Storage Array SoftwareUnidentified DevicesAn unidentified node or device occurs when MDSM cannot access a new storage array.

Página 178 - Creating a Virtual Disk Copy

Troubleshooting: Your Storage Array Software 259ping <host-name-or-IP-address-of-the-host>. If the network can access the host, continue to step

Página 179 - Failed Virtual Disk Copy

26 Planning: About Your Storage Array3 Split mode LED This LED must be unlit as the split mode function is not supported by the MD3200i Series Storage

Página 180 - Copying the Virtual Disk

260 Troubleshooting: Your Storage Array Software5Make sure that the controller firmware is compatible with MDSM on your management station. If the con

Página 181

Troubleshooting: Your Storage Array Software 261or Click Start Administrative Tools Services. 2In the Services dialog, select Modular Disk Storage M

Página 182 - Setting Copy Priority

262 Troubleshooting: Your Storage Array Softwarebook.book Page 262 Saturday, September 24, 2011 9:06 AM

Página 183 - Recopying a Virtual Disk

Troubleshooting: Your Array 26320Troubleshooting: Your ArraySafety First—For you and Your Array CAUTION: Many repairs may only be done by a certified

Página 184

264 Troubleshooting: Your ArrayTroubleshooting Power Supply/Cooling Fan Module CAUTION: Many repairs may only be done by a certified service technici

Página 185 - Re-Copying a Virtual Disk

Troubleshooting: Your Array 265Troubleshooting Array Cooling Problems CAUTION: Many repairs may only be done by a certified service technician. You m

Página 186 - Removing Copy Pairs

266 Troubleshooting: Your ArraycReseat the EMM module and wait for 30 seconds. See "Removing an EMM" in the MD1200 and MD1220 Storage Enclos

Página 187

Troubleshooting: Your Array 267Troubleshooting RAID Controller Modules CAUTION: Many repairs may only be done by a certified service technician. You

Página 188

268 Troubleshooting: Your ArrayeCheck the link status LED. If the link status LED is not green, replace the cables.If the problem is not resolved, see

Página 189 - Multipath for Linux

Troubleshooting: Your Array 269Troubleshooting Array and Expansion Enclosure Connections1Verify that the RAID controller module port link status LED a

Página 190 - Using DM Multipathing Devices

Planning: About Your Storage Array 27Back Panel Features and IndicatorsFigure 2-4. Back-Panel Features and Indicators—Dell PowerVault MD3200i Series1

Página 191

270 Troubleshooting: Your Array•Hard drives• RAID controller modules• Power supply/cooling fan modules• Control panel•Backplane3Let the system dry tho

Página 192

Troubleshooting: Your Array 271Troubleshooting RAID Controller ModulesConditionsCertain events can cause a RAID controller module to fail and/or shut

Página 193

272 Troubleshooting: Your ArrayPCI ErrorsThe storage array firmware can detect and only recover from PCI errors when the RAID controller modules are c

Página 194 - Ready For Use

Getting Help 27321Getting HelpContacting DellFor customers in the United States, call 800-WWW-DELL (800-999-3355). NOTE: If you do not have an activ

Página 195

274 Getting Helpbook.book Page 274 Saturday, September 24, 2011 9:06 AM

Página 196

Index 275Index AAccess Virtual Disk, 66Advanced FeatureUsing Snapshot and Disk Copy Together, 5 4Advanced Features, 50Snapshot Repository Virtual Disk

Página 197 - Limitations and Known Issues

Index 276contacting Dell, 273control panelinstalling, 230removing, 229Copy Manager, 180DDefining a Host, 96Dellcontacting, 273Disk GroupCreating, 106E

Página 198 - Troubleshooting

Index 277Free Capacity, 142front bezelinstalling, 212removing, 212Hhard drivedrive carrier, 216installing, 216removing, 214Hard-Drive Indicator Patter

Página 199

Index 278Media Errors and Unreadable Sectors, 210Media ScanChanging settings, 146Suspending, 147MicrosoftVirtual Disk Service, 237Volume Shadow-Copy S

Página 200

Index 279front bezel, 212hard drive, 214hard drive from a drive carrier, 216power supply/cooling fan module, 225Removing Copy Pairs, 186Removing Host

Página 201 - Packages

28 Planning: About Your Storage ArrayHard-Drive Indicator PatternsFigure 2-5. Hard Drive Indicators1 hard-drive activity indicator (green) 2 hard-dri

Página 202 - Firmware

Index 280Starting or Restarting the Host-Agent Software, 260Start-Up Routine, 239Storage Array Profile, 246Storage Array Support Data, 242Unidentified

Página 203

Index 281Virtual Disk Operations Limit, 45Virtual Disk Ownership, 55Virtual Disk States, 40Virtual DiskCopyTa rg e t , 5 3Virtual Disks and Disk Group

Página 204

282 Indexbook.book Page 282 Saturday, September 24, 2011 9:06 AM

Página 205

Planning: About Your Storage Array 29Power Supply and Cooling Fan FeaturesThe MD3200i Series storage array includes two integrated, hot-swappable powe

Página 206

Contents 3Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . 19About This Document . . . . . . . . . . . . . . . . . . 19Inside

Página 207

30 Planning: About Your Storage ArrayPower Indicator Codes and FeaturesFigure 2-6. Power Indicator Codes and FeaturesItem LED Type Icon Description1 D

Página 208 - EMM Firmware

Planning: RAID Controller Modules 313Planning: RAID Controller ModulesRAID Controller ModulesThe RAID controller modules provide high-performance, adv

Página 209

32 Planning: RAID Controller ModulesRAID Controller Module Connectors and FeaturesFigure 3-1. MD3200i Series iSCSI RAID Controller ModuleItem Componen

Página 210 - Technology (SMART)

Planning: RAID Controller Modules 338SAS OUT port link/fault LEDLights green when all four links are connected.Lights amber when one to 3 links are di

Página 211 - Components

34 Planning: RAID Controller ModulesRAID Controller Module—Additional FeaturesBattery Backup UnitEach RAID controller contains a two-cell Lithium ion

Página 212 - Front Bezel (Optional)

Planning: RAID Controller Modules 35System Password ResetThe storage array system password can be reset if it is forgotten. To reset the password, pus

Página 213 - Hard Drives

36 Planning: RAID Controller Modulesmirrored to the cache of the second controller before completion status is issued to the host initiator. Write-Bac

Página 214 - Removing a Hard Drive

Planning: MD3200i Series Storage Array Terms and Concepts 374Planning: MD3200i Series Storage Array Terms and ConceptsThis chapter explains terms and

Página 215

38 Planning: MD3200i Series Storage Array Terms and Concepts NOTE: The MD3200i Series storage enclosure must contain at least two physical disks for

Página 216 - Installing a Hard Drive

Planning: MD3200i Series Storage Array Terms and Concepts 39If a disk drive rebuild fails because of a source drive failure or because the drive is to

Página 217

4 Contents3 Planning: RAID Controller Modules. . . . 31RAID Controller Modules . . . . . . . . . . . . . . . . 31RAID Controller Module Connector

Página 218

40 Planning: MD3200i Series Storage Array Terms and ConceptsDisk groups are always created in the unconfigured capacity of a storage array. Unconfigur

Página 219 - RAID Controller Module

Planning: MD3200i Series Storage Array Terms and Concepts 41Each RAID level provides different performance and protection. You must select a RAID leve

Página 220

42 Planning: MD3200i Series Storage Array Terms and Conceptsis recommended for small databases or other applications that do not require large capacit

Página 221

Planning: MD3200i Series Storage Array Terms and Concepts 43The segment size or stripe element size specifies the size of data in a stripe written to

Página 222

44 Planning: MD3200i Series Storage Array Terms and ConceptsConsistency CheckA consistency check verifies the correctness of data in a redundant array

Página 223

Planning: MD3200i Series Storage Array Terms and Concepts 45Virtual Disk Operations LimitThe maximum number of active, concurrent virtual disk process

Página 224

46 Planning: MD3200i Series Storage Array Terms and ConceptsWhen considering a segment-size change, two scenarios illustrate different approaches to t

Página 225

Planning: MD3200i Series Storage Array Terms and Concepts 47Disk Group Operations LimitThe maximum number of active, concurrent disk group processes p

Página 226

48 Planning: MD3200i Series Storage Array Terms and ConceptsThe priority of each of these operations can be changed to address performance requirement

Página 227

Planning: MD3200i Series Storage Array Terms and Concepts 49 NOTE: Only disk groups and associated virtual disks with all member physical disks prese

Página 228

Contents 5Foreground Initialization . . . . . . . . . . . . . . 43Consistency Check . . . . . . . . . . . . . . . . . 44Media Verification . . . .

Página 229 - Control Panel

50 Planning: MD3200i Series Storage Array Terms and Conceptsthat has no existing physical disks. After the destination storage array is turned on and

Página 230 - Installing the Control Panel

Planning: MD3200i Series Storage Array Terms and Concepts 51Host Server-to-Virtual Disk MappingThe host server attached to a storage array accesses va

Página 231 - Backplane

52 Planning: MD3200i Series Storage Array Terms and Conceptsonline and user-accessible. When the backup is completed, the snapshot virtual disk is no

Página 232

Planning: MD3200i Series Storage Array Terms and Concepts 53Virtual Disk CopyVirtual disk copy is a premium feature to:•Back up data• Copy data from d

Página 233

54 Planning: MD3200i Series Storage Array Terms and ConceptsVirtual Disk RecoveryYou can use the Edit host server-to-virtual disk mappings feature to

Página 234 - Installing the Backplane

Planning: MD3200i Series Storage Array Terms and Concepts 55The multi-path software identifies the existence of multiple paths to a virtual disk and e

Página 235

56 Planning: MD3200i Series Storage Array Terms and ConceptsOwnership can later be modified to balance workload according to actual usage. If virtual

Página 236

Planning: MD3200i Series Storage Array Terms and Concepts 57• Least path weight with subset (Windows operating systems only)—The least queue depth wit

Página 237 - Management: System Interfaces

58 Planning: MD3200i Series Storage Array Terms and Concepts• RAID Controller modules•Virtual disks• Storage array totals NOTE: By default, all items

Página 238

Planning: MD3200i Series Storage Array Terms and Concepts 59The Performance Monitor data provides information about how your storage array is performi

Página 239 - Array Software

6 ContentsMonitoring MD3200i Series System Performance . . . . . . . . . . . . . . . . . . . . . . . 575 Configuration: Overview . . . . . . . . .

Página 240

60 Planning: MD3200i Series Storage Array Terms and Conceptsbook.book Page 60 Saturday, September 24, 2011 9:06 AM

Página 241

Configuration: Overview 615Configuration: OverviewDell PowerVault Modular Disk Storage Manager (MDSM) online help contains information on how to use t

Página 242 - Storage Array Support Data

62 Configuration: OverviewEnterprise Management WindowThe EMW provides high-level management of storage arrays. When you start MDSM, the EMW is displa

Página 243

Configuration: Overview 63Inheriting the System SettingsUse the Inherit System Settings option to import the operating system theme settings into the

Página 244 - Event Log

64 Configuration: Overview• Logical tab—You can view the organization of the storage array by virtual disks, disk groups, free capacity nodes, and any

Página 245 - Recovery Guru

Configuration: About Your Storage Array 656Configuration: About Your Storage ArrayOut-of-Band and In-Band ManagementYou can manage a storage array in

Página 246 - Storage Array Profile

66 Configuration: About Your Storage ArrayIn-Band ManagementUsing in-band management, commands, events, and data travel through the host-to-controller

Página 247

Configuration: About Your Storage Array 67 NOTE: For Linux, set the default gateway so that broadcast packets are sent to 255.255.255.0. For Red Hat

Página 248 - Finding Nodes

68 Configuration: About Your Storage Array NOTE: When adding a storage array using in-band management with iSCSI, a session must first be established

Página 249

Configuration: About Your Storage Array 69• Configure the storage array—Create disk groups, virtual disks, and hot spare physical disks by using the A

Página 250 - Using Go To

Contents 7Configuring E-mail Alerts . . . . . . . . . . . . . . 76Configuring SNMP Alerts. . . . . . . . . . . . . . 79Battery Settings . . . . .

Página 251 - Condition

70 Configuration: About Your Storage Array• In the AMW, select Storage ArrayBlinkStorage Array.The LEDs blink on the physical disks in the storage

Página 252

Configuration: About Your Storage Array 715Click Yes.The new storage array name is displayed in the Select storage array table.6Repeat step 2 through

Página 253 - Locating a Physical Disk

72 Configuration: About Your Storage Array6Click OK. NOTE: You are not prompted for a password when you attempt to change the storage array configura

Página 254

Configuration: About Your Storage Array 73Adding/Editing a Comment to an Existing Storage ArrayA descriptive comment, with an applicable storage array

Página 255

74 Configuration: About Your Storage ArrayEnabling Premium FeaturesYou can enable premium features on the storage array. To enable the premium feature

Página 256

Configuration: About Your Storage Array 752Select or enter the percentage of unwritten data in the cache to trigger a cache flush in Start flushing.3S

Página 257 - SMrepassist Utility

76 Configuration: About Your Storage Array3Click OK.If you have set a password for the selected storage array, the Enter Password dialog is displayed.

Página 258 - Unidentified Devices

Configuration: About Your Storage Array 77To configure e-mail alerts:1Open the Configure Alerts dialog by performing one of these actions:• In the Tre

Página 259

78 Configuration: About Your Storage Array• Adding an e-mail address—In Email address, type the e-mail address, and click Add. • Replacing an e-mail a

Página 260 - Software

Configuration: About Your Storage Array 79• The e-mail addresses that you had previously configured are displayed in the Configured e-mail addresses a

Página 261

8 ContentsLinux. . . . . . . . . . . . . . . . . . . . . . . . . 949 Configuration: About Your Host . . . . . . . 95Configuring Host Access. . . .

Página 262

80 Configuration: About Your Storage Array NOTE: The community name is an American Standard Code for Information Interchange (ASCII) string that iden

Página 263 - Troubleshooting: Your Array

Configuration: About Your Storage Array 81The learn cycle completes the following operations:• Discharges the battery to a predetermined threshold • C

Página 264

82 Configuration: About Your Storage Arraywritten by the RAID controller modules to the Event Log match the event timestamps written to host log files

Página 265 - Management Modules

Configuration: Using iSCSI 837Configuration: Using iSCSIChanging the iSCSI Target Authentication1In the AMW, select the Setup tab.2Select Manage iSCSI

Página 266

84 Configuration: Using iSCSIEntering Mutual Authentication PermissionsMutual authentication or two-way authentication enables a client or a user to v

Página 267

Configuration: Using iSCSI 85Initiator CHAP SecretThe initiator CHAP secret is set on the host using the iSCSI initiator configuration program provide

Página 268 - Troubleshooting Hard Drives

86 Configuration: Using iSCSIChanging the iSCSI Target IdentificationYou cannot change the iSCSI target name, but you can associate an alias with the

Página 269 - Connections

Configuration: Using iSCSI 87• Select Specify Configuration, and type the IPv4 address to activate the target discovery.• Type the iSNS server IP addr

Página 270

88 Configuration: Using iSCSI4To use the IPv4 settings for the iSCSI host port, select Enable IPv4 and select the IPv4 Settings tab.5To use the IPv6 s

Página 271 - ECC Errors

Configuration: Using iSCSI 89Advanced iSCSI Host Ports Settings NOTE: Configuring the advanced iSCSI host ports settings is optional.Use the advanced

Página 272 - Noncritical Conditions

Contents 9Changing the I/O Type . . . . . . . . . . . . . . . 114Choosing an Appropriate Physical Disk Type. . . . . . 115Physical Disk Security wi

Página 273 - Getting Help

90 Configuration: Using iSCSIViewing or Ending an iSCSI SessionYou may want to end an iSCSI session for the following reasons:• Unauthorized access—If

Página 274 - 274 Getting Help

Configuration: Using iSCSI 91Viewing iSCSI Statistics and Setting Baseline StatisticsTo view iSCSI statistics and set baseline statistics:1In the AMW

Página 275 - Index 275

92 Configuration: Using iSCSIEdit, Remove, or Rename Host TopologyIf you give access to the wrong host or the wrong host group, you can remove or edit

Página 276 - Index 276

Configuration: Event Monitor 938Configuration: Event MonitorAn event monitor is provided with Dell PowerVault Modular Disk Storage Manager (MDSM). The

Página 277 - Index 277

94 Configuration: Event MonitorWindowsTo enable or disable the event monitor:1Click Start Administrative Tools Services. or Click Start Settings C

Página 278 - Index 278

Configuration: About Your Host 959Configuration: About Your HostConfiguring Host AccessModular Disk Storage Manager (MDSM) software is comprised of mu

Página 279 - Index 279

96 Configuration: About Your Host• Create a host and assign an alias or user label.• Add or associate a new host port identifier to a particular host.

Página 280 - Index 280

Configuration: About Your Host 97• Select the Mappings tab. Right-click the root node (storage array name), Default Group node, or Host Group node in

Página 281 - Index 281

98 Configuration: About Your HostThe Preview window is displayed.11Click Finish.Removing Host AccessTo remove host access:1In the AMW, select the Mapp

Página 282 - 282 Index

Configuration: About Your Host 99• Right-click the storage array or the Default Group, and select Define Host Group from the pop-up menu.4Type the na

Comentários a estes Manuais