Dell PowerVault MD3860f Manual do Proprietário

Consulte online ou descarregue Manual do Proprietário para Matrizes de discos Dell PowerVault MD3860f. Dell PowerVault MD3860f Owner`s manual [de] [en] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Owner's Manual

Dell PowerVault MD3860f Storage ArraysOwner's ManualRegulatory Model: E08J SeriesRegulatory Type: E08J001

Página 2 - Notes, Cautions, and Warnings

Item Indicator Icon Description8 Drive activity indicatorNOTE: The associated physical disk is indicated by a number (0 to 11) that is displayed above

Página 3 - Contents

Cooling Fan Module LED Indicator CodesFigure 5. Cooling Fan Module IndicatorsItem Indicator Icon Description1 Power indicator The power indicator ligh

Página 4

Power Supply Module Features And Indicators NOTE: Your storage array is shipped with two IEC C19 to C20 jumper cords. Connect the C19 plug to the arra

Página 5

Item Indicator or Connector Icon DescriptionOff Indicates that you cannot remove the power supply module from the system.6 Service action required ind

Página 6 - About your system

Item Indicator Icon Description1 Service action allowed indicatorCAUTION: Remove the physical disk from the system only if the service action allowed

Página 7 - Front-Panel Features

2Controller ModulesRAID Controller ModulesRAID controller modules provide high-performance, advanced virtual disk configuration, and fault-tolerant di

Página 8 - Front-Panel Indicators

Item Indicator, Button, or ConnectorIcon Description3 12 Gbps SAS IN port (2) Provides host-to-controller SAS connection.4 USB port Reserved port.5 Mi

Página 9

SFP+ Transceivers Fibre Optic And SAS CablesNOTE: Your small form-factor pluggable (SFP+) transceivers and cables may look different from the ones sho

Página 10 - Back-Panel Features

Figure 10. SAS Cable1. mini SAS connector 2. SAS cable3. mini SAS HD connectorExpansion Controller ModulesUse the expansion controller modules to expa

Página 11

Item Indicator, Button, or ConnectorIcon Description5 SAS OUT port Provides SAS connection for cabling to a downchain expansion enclosure.6 Diagnostic

Página 12

Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates

Página 13 - Physical-Disk LED Indicators

Table 2. Shutdown Threshold TypeThreshold Temperature Exceeding Event DescriptionNominal failure threshold A critical event is setMaximum failure thre

Página 14

3Installing and removing system components Recommended ToolsYou may need the following items to perform the procedures in this section:• #2 Phillips s

Página 15 - Controller Modules

Figure 12. Removing and Installing the Front Bezel1. release latches (2) 2. front bezel3. guide pins (4)Removing The Front BezelYou must remove the fr

Página 16

Figure 13. Inside the Physical-Disk Drawer1. release latch (2) 2. physical-disk bay (12)3. physical-disk connector (12) 4. SAS cable connection (2)5.

Página 17

Figure 14. Opening and Closing the Physical-Disk Drawer1. physical-disk drawer 2. release latchClosing The Physical-Disk DrawerCAUTION: Many repairs m

Página 18 - Expansion Controller Modules

For more information, see the Dell PowerVault MD Series Storage Arrays Administrator's Guide at dell.com/powervaultmanuals.2. Remove the front be

Página 19 - Battery Backup Unit

Figure 15. Removing and Installing the Physical-Disk Drawer1. physical-disk drawer 2. release tabInstalling The Physical-Disk DrawerCAUTION: Many repa

Página 20 - System Password Reset

6. Install the front bezel.7. Using the MD Storage Manager, verify that the new physical-disk drawer is identified and operating correctly.Physical Di

Página 21 - Recommended Tools

Figure 17. Removing and Installing the 2.5 Inch Physical Disk in a 2.5 Inch Physical-Disk Carrier1. 2.5 inch physical drive cage 2. guide pin (4)3. re

Página 22 - Physical-Disk Drawers

Figure 18. Removing and Installing the 3.5 Inch Physical Disk in a 3.5 Inch Physical-Disk Carrier1. 3.5 inch physical disk 2. release handle3. holes o

Página 23

Contents1 About your system... 6Introduction...

Página 24

Removing A Physical Disk From A Physical-Disk DrawerCAUTION: Many repairs may only be done by a certified service technician. You should only perform

Página 25

7. release tab (12)Installing A Physical Disk In A Physical-Disk DrawerCAUTION: Many repairs may only be done by a certified service technician. You s

Página 26

3. SAS chain cable (two per physical-disk drawer)Removing The SAS Chain Cable(s)CAUTION: Many repairs may only be done by a certified service technici

Página 27 - Physical Disks

Figure 21. Removing and Installing the SAS Chain Cable(s)1. left cooling fan module bay 2. right cooling fan module bay3. SAS cable connector on the m

Página 28

CAUTION: If you are hot swapping the SAS cable chains, ensure that you complete the procedure on one side within ten minutes to avoid over heating of

Página 29

Figure 22. Removing and Installing a RAID Controller Module or Expansion Module1. RAID controller module or expansion module2. release lever3. release

Página 30

Opening The RAID Controller ModuleCAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting an

Página 31 - SAS Chain Cables

Replacing The SFP+ TransceiverCAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and si

Página 32

RAID Controller Module Backup Battery UnitThe battery backup unit provides backup power to the RAID controllers in case of power failure. It ensures p

Página 33

Installing The RAID Controller Module Backup Battery UnitYou must replace the RAID controller battery backup unit immediately to ensure the security o

Página 34 - RAID Controller Modules

Removing A Physical Disk From A Physical-Disk Drawer...30Installing A Physical Disk In A Phys

Página 35

NOTE: The Service action required indicator lights amber when there is a fault in the power supply module.2. Disconnect the power cable from the power

Página 36

CAUTION: When connecting the power cable, secure the cable with the cable securing bracket.NOTE: When installing or hot-swapping a new power supply mo

Página 37

Figure 27. Removing and Installing the Cooling Fan Module1. cooling fan module release latch 2. cooling fan module handle3. cooling fan moduleInstalli

Página 38

4Troubleshooting your systemSafety first—for you and your systemCAUTION: Many repairs may only be done by a certified service technician. You should o

Página 39 - Power Supplies

NOTE: Equip yourself with antistatic protection and a replacement small form-factor pluggable (SFP+) transceiver before replacing an SFP+ transceiver

Página 40

8. Reconnect the fiber optic cable.9. View the FC IN speed LEDs and the Physical Disk Channel speed LEDs.Based on the LED status, perform one of these

Página 41 - Cooling Fan Modules

NOTE: After installing a power supply module, allow several seconds for the array to recognize the power supply module and to determine if it is worki

Página 42

If The Link Status LEDs Are Not Green1. Turn off the host server.2. Reseat the cables on the expansion array and the server.3. Turn on the expansion a

Página 43 - Troubleshooting your system

4. Reinstall the physical disk.5. If the problem is not resolved, replace the failed physical disk.If the problem persists, see Getting Help.Troublesh

Página 44

Troubleshooting A Damaged ArrayCAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and s

Página 45

ECC Errors... 50PCI

Página 46 - Sequence)

• One RAID controller module in a redundant configuration has failed• A battery has failed or has been removed• A physical disk in a redundant virtual

Página 47

5Technical SpecificationsPhysical DisksPhysical disks Up to sixty 3.5 inch or 2.5 inch SAS or nearline SAS physical disks or 2.5 inch SAS SSDsRAID Con

Página 48 - Connections

Back-Panel Connectors (Per RAID Controller Module)NOTE: SAS and FC connections to the same host is not supported.Two SAS OUT ports, it is recommended

Página 49 - Controller Failure Conditions

EnvironmentalNOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datashee

Página 51 - Technical Specifications

6Getting help Locating your system service tagYour system is identified by a unique Express Service Code and Service Tag number. The Express Service C

Página 52

1About your system IntroductionCAUTION: See the Safety, Environmental, and Regulatory Information document for important safety information before fol

Página 53

• Dell PowerVault MD Series Storage Arrays Administrator's Guide — Provides information about configuring and managing the system using the MDSM

Página 54

Front-Panel Indicators Figure 2. Front-Bezel IndicatorsFigure 3. Front-Panel Indicators8

Página 55 - Getting help

Item Indicator Icon Description1 Power-on indicator The power-on indicator lights green when at least one power supply module is supplying power to th

Comentários a estes Manuais

Sem comentários