Dell Serial Attached SCSI 5iR Integrated and Adapter Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware de computador Dell Serial Attached SCSI 5iR Integrated and Adapter. Dell Serial Attached SCSI 5iR Integrated and Adapter User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
www.dell.com | support.dell.com
Dell™ Serial-Attached SCSI 5/iR
Integrated and Adapter
User’s Guide
Model UCS-51
YD912bk1.book Page 1 Monday, April 2, 2007 4:39 PM
Vista de página 0
1 2 3 4 5 6 ... 67 68

Resumo do Conteúdo

Página 1 - User’s Guide

www.dell.com | support.dell.comDell™ Serial-Attached SCSI 5/iRIntegrated and AdapterUser’s GuideModel UCS-51YD912bk1.book Page 1 Monday, April 2, 20

Página 2

8 Safety InstructionsIn addition, take note of these safety guidelines when appropriate:• When you disconnect a cable, pull on its connector or on its

Página 3

Overview 9OverviewThe Dell™ Serial-Attached SCSI (SAS) 5/iR controller is Dell’s next generation of controller with integrated redundant array of inde

Página 4 - Notes, Notices, and Cautions

10 OverviewAbout RAIDRAID is a group of multiple independent physical disks that provide high performance by increasing the number of drives used for

Página 5 - Contents

Overview 11Integrated MirroringWith Integrated Mirroring (RAID 1), data written to one disk is simultaneously written to another disk. If one disk fai

Página 6 - 4 Contents

12 OverviewYD912bk1.book Page 12 Monday, April 2, 2007 4:39 PM

Página 7

SAS 5/iR Features 13SAS 5/iR FeaturesThis section provides the specifications of Dell™ Serial-Attached SCSI (SAS) 5/iR controller. The following table

Página 8 - 6 Contents

14 SAS 5/iR FeaturesHot add / Hot remove of end devices Yes YesSMART error support through management applicationsYes YesHardware-based RAID RAID 0, R

Página 9 - CAUTION: Safety Instructions

Hardware Installation 15Hardware InstallationThis chapter describes how to install the Dell™ Serial-Attached SCSI (SAS) 5/iR Adapter. NOTE: The SAS 5

Página 10 - 8 Safety Instructions

16 Hardware InstallationFigure 3-1. Installing a SAS 5/iR Adapter7Tighten the bracket screw, if any, or use the system’s retention clips to secure the

Página 11 - Overview

Hardware Installation 17Figure 3-2. Connecting the Cable9Replace the cover of the system. See your system’s Hardware Owner’s Manual or the User’s Guid

Página 12 - RAID Terminology

YD912bk1.book Page 2 Monday, April 2, 2007 4:39 PM

Página 13 - Integrated Mirroring

18 Hardware InstallationYD912bk1.book Page 18 Monday, April 2, 2007 4:39 PM

Página 14 - 12 Overview

Driver Installation 19Driver InstallationThe Dell™ Serial-Attached SCSI (SAS) 5/iR controller requires software drivers to operate with Microsoft® Win

Página 15 - SAS 5/iR Features

20 Driver InstallationInstalling the Driver During Windows Operating System Installation NOTE: You do not need to install the driver on the Windows V

Página 16 - 14 SAS 5/iR Features

Driver Installation 216On the Locate device driver screen, select Search for a suitable driver for my device and click Next.7Provide the appropriate d

Página 17 - Hardware Installation

22 Driver InstallationInstalling From the Dell Operating System MediaUse the Operating System media CD or DVD that came with your Dell Precision works

Página 18

Driver Installation 23Creating a Driver Update DisketteThe following files are needed before you create the DUD. NOTE: The SAS 5/iR driver package in

Página 19

24 Driver InstallationInstalling the Driver Using an Update RPMThe following steps explain the installation procedure for the Red Hat Enterprise Linux

Página 20 - 18 Hardware Installation

Driver Installation 25Perform the following steps to create the DUD using the DKMS tool.1Install the DKMS-enabled SAS 5/iR driver rpm package on a sys

Página 21 - Driver Installation

26 Driver InstallationUpgrading the KernelIf you run the up2date utility to upgrade the kernel, the DKMS enabled driver packages must be reinstalled.

Página 22 - Installation

SAS 5/iR BIOS 27SAS 5/iR BIOSThe BIOS of the Dell™ Serial-Attached SCSI (SAS) 5/iR controller (also known as CTRL-C) offers the following features:• S

Página 23 - Driver Installation 21

www.dell.com | support.dell.comDell™ Serial-Attached SCSI 5/iRIntegrated and AdapterUser’s GuideYD912bk1.book Page 1 Monday, April 2, 2007 4:39 PM

Página 24 - Creating a Driver Diskette

28 SAS 5/iR BIOSConfiguration UtilityStarting the Configuration Utility1Boot the system.2Press <Ctrl+C> during POST when prompted.If you wait to

Página 25 - Installing the Driver

SAS 5/iR BIOS 29Integrated RAID Configuration and Management ScreensIntegrated RAID (IR) configuration and management involves many screens, all of wh

Página 26

30 SAS 5/iR BIOSView Virtual DiskThe View Virtual Disk screen allows you to view the current virtual disk configuration.Press <Alt+N> to view th

Página 27 - Driver Installation 25

SAS 5/iR BIOS 31Exit ScreenIt is important to exit the SAS BIOS Configuration Utility properly, because some changes take effect only when you exit. F

Página 28 - Upgrading the Kernel

32 SAS 5/iR BIOS3Select Create IS Volume when you are prompted to create either an IS virtual disk or an IM virtual disk.The next screen shows a list

Página 29 - SAS 5/iR BIOS

SAS 5/iR BIOS 335As disks are added, the Virtual Disk Size field will change to reflect the size of the new virtual disk. There are several limitation

Página 30 - Configuration Utility

34 SAS 5/iR BIOSActivating a Virtual DiskA virtual disk can become inactive if, for example, it is removed from one SAS 5/iR controller and moved to a

Página 31 - Create New Virtual Disk

Troubleshooting 35TroubleshootingTo get help with problems with your Dell™ Serial-Attached SCSI (SAS) 5/iR controller, you can Contact Dell or access

Página 32 - Manage Virtual Disk

36 TroubleshootingPhysical Disk Related IssuesTable 6-2. Physical Disk IssuesProblem Suggested SolutionThe system does not boot from the SAS 5/iR cont

Página 33 - Exit Screen

Troubleshooting 37Configuration Utility Error Messages NOTE: These error messages are displayed inside the Configuration Utility. Restart your system

Página 34

Notes, Notices, and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE: A NOTICE indicates

Página 35 - Synchronizing a Virtual Disk

38 TroubleshootingBIOS Error MessagesTable 6-4. BIOS Error MessagesMessage MeaningPress <Ctrl+C> to Enable BIOS When the BIOS is disabled, you a

Página 36 - Deleting a Virtual Disk

Troubleshooting 39Device not available at Device may not be ready at this time. The device will be retried. If the problem persists, restart your syst

Página 37 - Troubleshooting

40 TroubleshootingImage not found Could not locate the image for the Configuration Utility, its strings file, or its options file.Unable to load LSI C

Página 38 - Physical Disk Related Issues

Updating the Firmware 41Updating the FirmwareFirmware updates to the Dell™ Serial-Attached SCSI (SAS) 5/iR controller is achieved by flashing the firm

Página 39

42 Updating the FirmwareYD912bk1.book Page 42 Monday, April 2, 2007 4:39 PM

Página 40 - BIOS Error Messages

Getting Help 43Getting HelpObtaining Assistance CAUTION: If you need to remove the computer cover, first disconnect the computer power and modem cabl

Página 41

44 Getting HelpOnline ServicesYou can access Dell Support at support.dell.com. Select your region on the WELCOME TO DELL SUPPORT page, and fill in the

Página 42 - 40 Troubleshooting

Getting Help 45Dell Enterprise TrainingDell Enterprise training is available; see www.dell.com/training for more information. This service may not be

Página 43 - Updating the Firmware

46 Getting HelpBefore You Call NOTE: Have your Express Service Code ready when you call. The code helps Dell's automated-support telephone syste

Página 44 - 42 Updating the Firmware

Regulatory Notices 47Regulatory NoticesElectromagnetic Interference (EMI) is any signal or emission, radiated in free space or conducted along power o

Página 45 - Getting Help

Contents 3ContentsCAUTION: Safety Instructions. . . . . . . . . . . . . . . . . . . . . 7SAFETY: General . . . . . . . . . . . . . . . . . . . . . .

Página 46 - Online Services

48 Regulatory NoticesFCC Notices (U.S. Only)FCC, Class BThis equipment generates, uses, and can radiate radio frequency energy and, if not installed a

Página 47 - Product Information

Regulatory Notice 49Industry Canada (Canada Only)Industry Canada, Class BThis Class B digital apparatus complies with Canadian NMB-003. NOTICE: The I

Página 48 - Before You Call

50 Regulatory NoticesYD912bk1.book Page 50 Monday, April 2, 2007 4:39 PM

Página 49 - Regulatory Notices

Regulatory Notice 51YD912bk1.book Page 51 Monday, April 2, 2007 4:39 PM

Página 50 - FCC Notices (U.S. Only)

52 Regulatory NoticesYD912bk1.book Page 52 Monday, April 2, 2007 4:39 PM

Página 51 - CE Notice (European Union)

Regulatory Notice 53YD912bk1.book Page 53 Monday, April 2, 2007 4:39 PM

Página 52 - 50 Regulatory Notices

54 Regulatory NoticesYD912bk1.book Page 54 Monday, April 2, 2007 4:39 PM

Página 53 - Regulatory Notice 51

Regulatory Notice 55Corporate Contact Details (Taiwan Only)Pursuant to Article 11 of the Commodity Inspection Act, Dell provides the following corpora

Página 54 - 52 Regulatory Notices

56 Regulatory NoticesYD912bk1.book Page 56 Monday, April 2, 2007 4:39 PM

Página 55 - Regulatory Notice 53

Regulatory Notice 57YD912bk1.book Page 57 Monday, April 2, 2007 4:39 PM

Página 56 - 54 Regulatory Notices

4 ContentsInstalling the Red Hat Enterprise Linux Driver . . . . . . . . . . . . . . . . . 22Creating a Driver Diskette . . . . . . . . . . . . . .

Página 57 - Regulatory Notice 55

58 Regulatory NoticesYD912bk1.book Page 58 Monday, April 2, 2007 4:39 PM

Página 58 - 56 Regulatory Notices

Glossary 59GlossaryThis section defines or identifies technical terms, abbreviations, and acronyms used in this document.AAdapterAn adapter enables th

Página 59 - Regulatory Notice 57

60 GlossaryDriverA device driver, often called a driver for short, is a program that allows the operating system or some other program to interface co

Página 60 - 58 Regulatory Notices

Glossary 61OOperating SystemThe software that runs a computer, including scheduling tasks, managing storage, and handling communication with periphera

Página 61 - Glossary

62 GlossaryRPMRPM, short for "Red Hat Package Manager" is a package management system primarily intended for Linux. RPM installs, updates, u

Página 62

Glossary 63SMARTAcronym for Self-Monitoring Analysis and Reporting Technology. The self-monitoring analysis and reporting technology (SMART) feature m

Página 63 - Glossary 61

64 GlossaryYD912bk1.book Page 64 Monday, April 2, 2007 4:39 PM

Página 64

Index 65IndexBBIOS, 27Configuration Utility, 28fault code messages, 27POST messages, 27CConfiguration Utilityfunctions performed, 28navigating, 28over

Página 65 - Glossary 63

66 Index66 IndexTtroubleshooting, 35BIOS boot order, 35BIOS error messages, 38Configuration Utility error messages, 37physical disk issues, 36WWindows

Página 66 - 64 Glossary

Contents 56 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35BIOS Boot Order . . . . . . . . . . . . . . . . . . . . .

Página 67 - Index 65

6 ContentsCE Notice (European Union) . . . . . . . . . . . . . . . . . . . . . . . . . . . 49European Union, Class B . . . . . . . . . . . . . . . .

Página 68 - 66 Index

Safety Instructions 7 CAUTION: Safety InstructionsUse the following safety guidelines to help ensure your own personal safety and to help protect you

Comentários a estes Manuais

Sem comentários