Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Introduction Indicators, Messages, and Codes Finding Software Solutions Running
Peripheral Component Interconnect PCMCIA Personal Computer Memory Card International Association PDB power distribution board PGA pin grid array POST
single-edge contact SDRAM synchronous dynamic random-access memory SIMM single in-line memory module SMB server management bus SNMP Simple Network Man
extended memory manager XMS eXtended Memory Specification Z ZIF zero insertion force Back to Contents Page
Back to Contents Page Introduction Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Other Documents You May Need Obtaining
Back to Contents Page Indicators, Messages, and Codes Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Indicators on the Syst
Front-Panel Indicators and Features Figure2-2 shows the controls, indicators, and connectors located behind the bezel on the system's front pane
l The two identification buttons on the front and back panels can be used to locate a particular system within a rack. When one of these buttons is pu
Power Supply Features Each hot-pluggable power supply has three indicators, visible when the system doors are open, that indicate whether power is pre
system board - please run SETUP program Setup program, NVRAM_CLR jumper is installed, or faulty system battery. the System Setup Program" in the
Memory parity error at address problem persists, see "Getting Help." No boot device available Faulty diskette, diskette/CD drive subsystem
Back to Contents Page Jumpers and Connectors Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Jumpers—AGeneralExplanation
System Beep Codes When an error that cannot be reported on the monitor occurs during a boot routine, the system may emit a series of beeps that identi
Warning Messages A warning message alerts you to a possible problem and asks you to take corrective action before the system continues a task. For exa
Back to Contents Page Finding Software Solutions Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Installing and Configuring
Back to Contents Page Table 3-1. IRQ Line Assignment DefaultsIRQ Line Used By/Available IRQ0 Used by the system timer IRQ1 Used by the keyboard
Back to Contents Page Running the System Diagnostics Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Features of the System
interaction and that do not take a long time to run. You should choose this option first to increase the chance of tracing the source of the problem q
Select The Select option in the Device Groups menu allows you to choose one or more devices from a particular device group. Three options are display
Back to Contents Page TroubleshootingYourSystem Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Safety First—For You and Y
4. Reconnect the system to the electrical outlet or PDU. If the system is still not receiving power, plug the system into another electrical outle
1. Look at the keyboard and the keyboard cable for any signs of damage. 2. Press and release each key on the keyboard. If the keyboard and its c
System Board Connectors See Figure6-1 and Table6-1 for the location and description of system board connectors. SCSI Backplane Board Connectors Fig
l System error message indicates problem l Device connected to the port not working Action 1. Enter the System Setup program and check that the USB
The system board can accommodate one or two microprocessors. A riser board accommodates one or two PCI expansion cards. Up to four memory modules ma
1. Observe the precautions in "Safety First—For You and Your System," found earlier in this section. Also observe the safety instructions i
3. Run the system board tests in the system diagnostics. If the tests did not complete successfully, see "Getting Help" for instructions
4. To install the replacement power supply, align the stud on the side of the power supply (see Figure5-5) with the corresponding notch in the chass
Action 1. Shut down the system and open the system doors (see "Opening the System Doors"). 2. Verify that each expansion card is firmly
Troubleshooting the System Board Problem l Error message indicates system board problem Action 1. Turn off the system, including any attached periph
l System cannot read data from a CD l CD drive indicator fails to flash during boot Action 1. Turn off the system, including any attached periphera
2. Check that the primary SCSI channel is enabled, and reboot the system. 3. Verify that the device drivers are installed and configured correctl
6. Reseat the ROMB card in its socket (see "Installing a ROMB Card" in "Installing System Board Options"). See Figure6-1 for
6. Install the jumper plug on the PASSWD jumper. 7. Replace the system cover, and then reconnect the system and peripherals to their electrical o
Back to Contents Page Installing System Board Options Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Installing Expansion C
Installing Expansion Cards Expansion cards are installed on the system's riser board (see Figure6-2). The riser board plugs into the RISER con
4. Remove the filler bracket from the expansion slot. 5. Install the new expansion card: a. Lower the card into the system. If the card is
Memory Module Installation Guidelines Starting with the socket farthest from the system power supply bay, the memory module sockets are labeled BANK1
To install a memory module, perform the following steps: 1. Press down and outward on the ejectors on the memory module socket, as shown in Figure6-
1. Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet. 1. Open the system doors (see &
8. Install the microprocessor chip in the socket (see Figure6-10). a. If the release lever on the microprocessor socket is not all the way up,
11. Close the system doors. 12. Reconnect your system and peripherals to their electrical outlets, and turn them on. As the system boots, it d
5. Secure the ROMB card with the thumbscrew (see Figure6-12). 6. Check that the ROMB back-up battery (see Figure6-12) is connected to the ROMB
6. Close the system doors. 7. Reconnect the system and any attached peripherals to their electrical outlets, and turn them on. 8. Enter the S
Back to Contents Page Abbreviations and Acronyms Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide The following list defines o
Back to Contents Page Installing Drives Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Installing SCSI Hard Drives Instal
5. Close the hard-drive handle to lock the drive in place. 6. Replace the front bezel, if it was removed in step 2. 7. Install any required SCS
12. Replace the front bezel, it it was removed in step 2. Installing a CD Drive The optional CD drive is contained in a carrier that slides into th
Ensure that you do not damage the ribbon cable at the back of the drive. Figure 7-4. Installing a Diskette Drive 7. Connect the drive data cable
Therefore, you should enable the tape drive's termination if it is the last device in a chain of devices (or sole device) connected to the SCSI c
Back to Contents Page Getting Help Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Help Overview Dell Contact Numbers Hel
[email protected] [email protected] (for Asian/Pacific countries only) l Electronic Information Service [email protected] AutoTech Service Dell's a
Dell Contact Numbers The following table provides country-specific access codes and telephone numbers, websites, and email addresses that you can us
International Access Code: 900 Country Code: 43 City Code: 1 Home/Small Business Fax 0179567605 Home/Small Business Customer Care 0179567603 Prefe
City Code: 2 Switchboard 02 22 83 27 11 Website: support.euro.dell.com E-mail: [email protected] Denmark (Horsholm) International Access Code: 0
CPU central processing unit DAC digital-to-analog converter DAT digital audio tape dB decibel(s) dBA adjusted decibel(s) DC direct current DIMM dual i
Country Code: 353 City Code: 1 Small Business Customer Care 012044026 Corporate Customer Care 01 279 5011 Sales 01 204 4444 SalesFax 012040144 Fax
Fax (Brussels, Belgium) 024819299 Switchboard (Brussels, Belgium) 024819100 Website: support.euro.dell.com E-mail: [email protected] Macau
International Access Code: 00 Country Code: 35 Customer Care 800 300 415 or 35800834075 Sales 800300410or800300411or800300412or 351 2
Back to Contents Page International Access Code: 002 Country Code: 886 Technical Support (Servers) tollfree:0080601256 Transaction Sales tol
EIDE enhanced integrated drive electronics EMI electromagnetic interference EMM expanded memory manager EMS Expanded Memory Specification EPP Enhanced
IDE integrated drive electronics IRQ interrupt request K kilo- (1024) KB kilobyte(s) KB/sec kilobyte(s) per second Kb kilobit(s) Kbps kilobit(s) per s
MB megabyte(s) Mb megabit(s) Mbps megabit(s) per second MBR master boot record MDA monochrome display adapter MGA monochrome graphics adapter MHz mega