Vista de página 0
Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide
Introduction
Indicators, Messages, and Codes
Finding Software Solutions
Running the System Diagnostics
TroubleshootingYourSystem
Installing System Board Options
Installing Drives
Getting Help
Jumpers and Connectors
Abbreviations and Acronyms
Notes, Notices, and Cautions
Information in this document is subject to change without notice.
©2001DellComputerCorporation.Allrightsreserved.
Reproduction in any manner whatsoever without the written permission of Dell Computer Corporation is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, DellNet, Dell OpenManage, Dimension, Inspiron, Dell Precision, OptiPlex, Latitude, and PowerEdge are trademarks of Dell Computer
Corporation; Intel is a registered trademark of Intel Corporation; Microsoft and Windows are registered trademarks of Microsoft Corporation.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Computer Corporation
disclaims any proprietary interest in trademarks and trade names other than its own.
Initial release: 19 Nov 01
NOTE: A NOTE indicates important information that helps you make better use of your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.
Vista de página 0
1 2 3 4 5 6 ... 62 63

Resumo do Conteúdo

Página 1 - Notes, Notices, and Cautions

Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Introduction Indicators, Messages, and Codes Finding Software Solutions Running

Página 2 - Jumpers and Connectors

Peripheral Component Interconnect PCMCIA Personal Computer Memory Card International Association PDB power distribution board PGA pin grid array POST

Página 3 - System Board Connectors

single-edge contact SDRAM synchronous dynamic random-access memory SIMM single in-line memory module SMB server management bus SNMP Simple Network Man

Página 4

extended memory manager XMS eXtended Memory Specification Z ZIF zero insertion force Back to Contents Page   

Página 5 - Abbreviations and Acronyms

Back to Contents Page Introduction Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Other Documents You May Need Obtaining

Página 6

Back to Contents Page Indicators, Messages, and Codes Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Indicators on the Syst

Página 7

Front-Panel Indicators and Features Figure2-2 shows the controls, indicators, and connectors located behind the bezel on the system's front pane

Página 8

l The two identification buttons on the front and back panels can be used to locate a particular system within a rack. When one of these buttons is pu

Página 9

Power Supply Features Each hot-pluggable power supply has three indicators, visible when the system doors are open, that indicate whether power is pre

Página 10

system board - please run SETUP program Setup program, NVRAM_CLR jumper is installed, or faulty system battery. the System Setup Program" in the

Página 11

Memory parity error at address problem persists, see "Getting Help." No boot device available Faulty diskette, diskette/CD drive subsystem

Página 12

Back to Contents Page Jumpers and Connectors Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Jumpers—AGeneralExplanation 

Página 13 - Introduction

System Beep Codes When an error that cannot be reported on the monitor occurs during a boot routine, the system may emit a series of beeps that identi

Página 14

Warning Messages A warning message alerts you to a possible problem and asks you to take corrective action before the system continues a task. For exa

Página 15

Back to Contents Page Finding Software Solutions Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Installing and Configuring

Página 16 - Back-Panel Features

Back to Contents Page    Table 3-1. IRQ Line Assignment DefaultsIRQ Line Used By/Available IRQ0 Used by the system timer IRQ1 Used by the keyboard

Página 17 - System Messages

Back to Contents Page Running the System Diagnostics Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Features of the System

Página 18

interaction and that do not take a long time to run. You should choose this option first to increase the chance of tracing the source of the problem q

Página 19

Select The Select option in the Device Groups menu allows you to choose one or more devices from a particular device group. Three options are display

Página 20 - System Beep Codes

Back to Contents Page TroubleshootingYourSystem Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Safety First—For You and Y

Página 21 - Diagnostics Messages

4. Reconnect the system to the electrical outlet or PDU. If the system is still not receiving power, plug the system into another electrical outle

Página 22 - Finding Software Solutions

1. Look at the keyboard and the keyboard cable for any signs of damage. 2. Press and release each key on the keyboard. If the keyboard and its c

Página 23

System Board Connectors See Figure6-1 and Table6-1 for the location and description of system board connectors. SCSI Backplane Board Connectors Fig

Página 24

l System error message indicates problem l Device connected to the port not working Action 1. Enter the System Setup program and check that the USB

Página 25 - Device Groups Menu Options

The system board can accommodate one or two microprocessors. A riser board accommodates one or two PCI expansion cards. Up to four memory modules ma

Página 26 - Error Messages

1. Observe the precautions in "Safety First—For You and Your System," found earlier in this section. Also observe the safety instructions i

Página 27 - TroubleshootingYourSystem

3. Run the system board tests in the system diagnostics. If the tests did not complete successfully, see "Getting Help" for instructions

Página 28 - Checking the Equipment

4. To install the replacement power supply, align the stud on the side of the power supply (see Figure5-5) with the corresponding notch in the chass

Página 29 - Problem

Action 1. Shut down the system and open the system doors (see "Opening the System Doors"). 2. Verify that each expansion card is firmly

Página 30 - Inside the System

Troubleshooting the System Board Problem l Error message indicates system board problem Action 1. Turn off the system, including any attached periph

Página 31 - Opening the System Doors

l System cannot read data from a CD l CD drive indicator fails to flash during boot Action 1. Turn off the system, including any attached periphera

Página 32 - Troubleshooting a Wet System

2. Check that the primary SCSI channel is enabled, and reboot the system. 3. Verify that the device drivers are installed and configured correctl

Página 33

6. Reseat the ROMB card in its socket (see "Installing a ROMB Card" in "Installing System Board Options"). See Figure6-1 for

Página 34 - Figure 5-6. Cooling Fan

6. Install the jumper plug on the PASSWD jumper. 7. Replace the system cover, and then reconnect the system and peripherals to their electrical o

Página 35

Back to Contents Page Installing System Board Options Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Installing Expansion C

Página 36 - Troubleshooting a CD Drive

Installing Expansion Cards Expansion cards are installed on the system's riser board (see Figure6-2). The riser board plugs into the RISER con

Página 37

4. Remove the filler bracket from the expansion slot. 5. Install the new expansion card: a. Lower the card into the system. If the card is

Página 38

Memory Module Installation Guidelines Starting with the socket farthest from the system power supply bay, the memory module sockets are labeled BANK1

Página 39

To install a memory module, perform the following steps: 1. Press down and outward on the ejectors on the memory module socket, as shown in Figure6-

Página 40

1. Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet. 1. Open the system doors (see &

Página 41 - Installing Expansion Cards

8. Install the microprocessor chip in the socket (see Figure6-10). a. If the release lever on the microprocessor socket is not all the way up,

Página 42 - Installing Memory

11. Close the system doors. 12. Reconnect your system and peripherals to their electrical outlets, and turn them on. As the system boots, it d

Página 43 - Installing Memory Modules

5. Secure the ROMB card with the thumbscrew (see Figure6-12). 6. Check that the ROMB back-up battery (see Figure6-12) is connected to the ROMB

Página 44 - Installing Microprocessors

6. Close the system doors. 7. Reconnect the system and any attached peripherals to their electrical outlets, and turn them on. 8. Enter the S

Página 45 - Figure 6-7. Retention Clip

Back to Contents Page Abbreviations and Acronyms Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide The following list defines o

Página 46

Back to Contents Page Installing Drives Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Installing SCSI Hard Drives Instal

Página 47 - Installing a ROMB Card

5. Close the hard-drive handle to lock the drive in place. 6. Replace the front bezel, if it was removed in step 2. 7. Install any required SCS

Página 48 - Replacing the System Battery

12. Replace the front bezel, it it was removed in step 2. Installing a CD Drive The optional CD drive is contained in a carrier that slides into th

Página 49

Ensure that you do not damage the ribbon cable at the back of the drive. Figure 7-4. Installing a Diskette Drive  7. Connect the drive data cable

Página 50 - Installing Drives

Therefore, you should enable the tape drive's termination if it is the last device in a chain of devices (or sole device) connected to the SCSI c

Página 51 - Installing an IDE Hard Drive

Back to Contents Page Getting Help Dell™PowerEdge™1650SystemsInstallationandTroubleshootingGuide Help Overview Dell Contact Numbers Hel

Página 52 - Installing a Diskette Drive

[email protected] [email protected] (for Asian/Pacific countries only) l Electronic Information Service [email protected] AutoTech Service Dell's a

Página 53

Dell Contact Numbers The following table provides country-specific access codes and telephone numbers, websites, and email addresses that you can us

Página 54 - Configuring the Boot Device

International Access Code: 900 Country Code: 43 City Code: 1 Home/Small Business Fax 0179567605 Home/Small Business Customer Care 0179567603 Prefe

Página 55 - Getting Help

City Code: 2 Switchboard 02 22 83 27 11 Website: support.euro.dell.com  E-mail: [email protected]  Denmark (Horsholm) International Access Code: 0

Página 56 - Before You Call

CPU central processing unit DAC digital-to-analog converter DAT digital audio tape dB decibel(s) dBA adjusted decibel(s) DC direct current DIMM dual i

Página 57 - Dell Contact Numbers

Country Code: 353 City Code: 1 Small Business Customer Care 012044026 Corporate Customer Care 01 279 5011 Sales 01 204 4444 SalesFax 012040144 Fax

Página 58

Fax (Brussels, Belgium) 024819299 Switchboard (Brussels, Belgium) 024819100 Website: support.euro.dell.com  E-mail: [email protected]  Macau

Página 59

International Access Code: 00 Country Code: 35 Customer Care 800 300 415 or 35800834075 Sales 800300410or800300411or800300412or 351 2

Página 60

Back to Contents Page    International Access Code: 002 Country Code: 886 Technical Support (Servers) tollfree:0080601256 Transaction Sales tol

Página 61

EIDE enhanced integrated drive electronics EMI electromagnetic interference EMM expanded memory manager EMS Expanded Memory Specification EPP Enhanced

Página 62

IDE integrated drive electronics IRQ interrupt request K kilo- (1024) KB kilobyte(s) KB/sec kilobyte(s) per second Kb kilobit(s) Kbps kilobit(s) per s

Página 63

MB megabyte(s) Mb megabit(s) Mbps megabit(s) per second MBR master boot record MDA monochrome display adapter MGA monochrome graphics adapter MHz mega