Dell PowerVault DP500 Manual do Utilizador Página 18

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 44
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 17
18 Detailed End-to-End iSCSI Setup
system. If no Target portals are listed, you can add them using the IP
address or DNS name of Target server. In the following example, two
iSCSI Target portals are already added.
Figure 2-2. Discovery Tab
iSNS Servers—You can also perform Target discovery using iSNS servers.
Add the iSNS Server IP address or DNS name. If the iSNS service is up
and running on a server, all clients (Initiators and Targets) that are
registered with the iSNS server are listed in the
Registered Clients
screen.
To retrieve this information on the iSNS server, go to
Microsoft iSNS
Properties
Registered Clients
.
Targets Tab
The Targets tab provides the list of individual Targets available to the iSCSI
Initiator. In the following example, three Targets are available to the iSCSI
Initiator.
Vista de página 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 43 44

Comentários a estes Manuais

Sem comentários