Dell OpenManage Server Administrator Version 6.5 Guia do Utilizador Página 96

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 250
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 95
96
Storage Management Message Reference
2108 SMART
warning
Warn ing /
Non-critical
Cause:
A disk has
received a SMART alert
(predictive failure).
The disk is likely to fail
in the near future.
Action:
Replace the
disk that has received
the SMART alert. If the
physical disk is a
member of a
non-redundant virtual
disk, then back up the
data before replacing
the disk.
CAUTION:
Removing a physical
disk that is included in a
non-redundant virtual
disk causes the virtual
disk to fail and may
cause data loss.
Clear Alert
Number:
None
Related Alert
Number:
None
LRA Number:
2070
903
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Vista de página 95
1 2 ... 91 92 93 94 95 96 97 98 99 100 101 ... 249 250

Comentários a estes Manuais

Sem comentários