174 Storage Management Message Reference
2264 A device is
missing.
Warning /
Non-critical
Cause: The controller
cannot communicate
with a device. The
device may be removed.
There may also be a bad
or loose cable.
Action: Check if the
device is in and not
removed. If it is in,
check the cables. You
should also check the
connection to the
controller battery and
the battery health.
A battery with a weak or
depleted charge
may cause this alert.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2050, 2060,
2070, 2080,
2090, 2100
753
803
853
903
953
1003
1053
1103
1153
1203
Table 4-4. Storage Management Messages (continued)