Dell OpenManage Server Administrator Version 6.1 Guia do Utilizador Página 144

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 252
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 143
144 Storage Management Message Reference
2174 The
controller
battery has
been
removed.
Warning /
Non-critical
Cause: The controller
cannot communicate
with the battery,
the battery may be
removed, or the contact
point between the
controller and the
battery may be burnt or
corroded.
Action: Replace the
battery if it has been
removed. If the contact
point between the
battery and the
controller is burnt or
corroded, you will need
to replace either the
battery or the controller,
or both. See the
hardware
documentation for
information on how to
safely access, remove,
and replace the battery.
Clear Alert
Number:
None.
Related Alert
Number:
2188, 2318
LRA Number:
2100
1153
2175 The
controller
battery has
been
replaced.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
1151
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Vista de página 143
1 2 ... 139 140 141 142 143 144 145 146 147 148 149 ... 251 252

Comentários a estes Manuais

Sem comentários