Event Message Reference 23
Cooling Device Messages
Cooling device sensors listed in Table 2-3 monitor how well a fan is
functioning. Cooling device messages provide status and warning information
for fans in a particular chassis.
Table 2-3. Cooling Device Messages
Event
ID
Description Severity Cause
1100 Fan sensor has
failed
Sensor location:
<Location in
chassis>
Chassis location:
<Name of chassis>
Previous state was:
<State>
Fan sensor value:
<Reading>
Information A fan sensor in the specified
system is not functioning. The
sensor location, chassis location,
previous state, and fan sensor
value are provided.
1101 Fan sensor value
unknown
Sensor location:
<Location in
chassis>
Chassis location:
<Name of chassis>
Previous state was:
<State>
Fan sensor value:
<Reading>
Information A fan sensor in the specified
system could not obtain a
reading. The sensor location,
chassis location, previous state,
and a nominal fan sensor value
are provided.