Storage Management Message Reference 147
2190 The
controller
has detected
a hot-
plugged
enclosure.
OK /
Normal
Cause: This alert is
provided for informational
purposes. The SAS
controller with firware
version 6.1 or later has
detected a hot-plugged
enclosure.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
751
2191 Multiple
enclosures
are attached
to the
controller.
This is an
unsupported
configuratio
n.
Critical /
Failure /
Error
Cause: Many enclosures are
attached to the controller
port. When the enclosure
limit is exceeded, the
controller loses contact
with all enclosures attached
to the port.
Action: Remove the last
enclosure. You must
remove the enclosure that
has been added last and is
causing the enclosure limit
to exceed.
Clear Alert
Number:
None.
Related Alert
Number: 2211
LRA Number:
2091
854
Table 4-4. Storage Management Messages (continued)