show-timezone (OPTIONAL) Enter the keyword show-timezone to include the
time zone information in the timestamp.
uptime (OPTIONAL) Enter the keyword uptime to have the timestamp based
on time elapsed since system reboot.
Defaults Not configured.
Command Modes CONFIGURATION
Command History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
If you do not specify parameters and enter service timestamps, it appears as service
timestamps debug uptime in the running-configuration.
Use the show running-config command to view the current options set for the
service timestamps command.
show alarms
View alarms for the stack-unit, switch, and fan trays.
S5000
Syntax
show alarms [threshold]
Parameters
threshold (OPTIONAL) Enter the keyword threshold to display the
temperature thresholds set for the stack-unit.
Command Modes
EXEC
EXEC Privilege
Command History
Version 9.0(1.3) Introduced on the S5000.
Example
FTOS#show alarms
-- Minor Alarms --
Alarm Type Duration
------------------------------------------------------------
No minor alarms
-- Major Alarms --
Alarm Type Duration
------------------------------------------------------------
fan tray 0 in unit 0 failed or removed 3 day, 23 hr, 6 min
fan tray 3 in unit 0 failed or removed 3 day, 23 hr, 6 min
FTOS#