22 Using Diagnostics
pediags
<DEVICECLASS
> --run [
<Index Options>
] [
<Test Settings>
] [fmt=
lst|tbl|xml]
This command runs tests on the device class you select. You can specify index options, test settings,
and choose the format in which you want the results to be displayed. The parameters should follow the
particular order in which they are listed above, format options must always be the last parameter.
In the
<Test Settings>
parameter, you can specify
quicktest
as
true
or
false
and you can specify the
number of iterations or passes for the selected test. Passes specifies the number of passes to execute.
For example, the command,
pediags network --run test-index=1,2,3 quicktest=
true passes=6 fmt=tbl
, runs six iterations of the tests whose index numbers are 1, 2, and 3 on
the network device class. The results are then displayed in a tabular format.
Runtime is limited to 3 days (72 hours). The minimum value is 1 and the maximum is 999.
NOTE: Running the pediags command on the device class from two different consoles simultaneously may
display the message:
System resources may have already been used by
another diagnostics instance
.
Aborting PowerEdge Diagnostics in CLI Mode Using <Ctrl><c>
Using <Ctrl><c> to abort with the --show command does not cause the action to abort. When
running tests, you may use <Ctrl><c> at any point of time during the execution sequence to stop the
test. No output may be available and the test may exit with a blank message. This may occur if the
execution of the pediags command has been interrupted even before the diagnostic test has started. If
you abort a test that has already started, the test may come out with a Test was aborted by the
user result event if the Abort feature is supported by the particular test. For multiple passes, even if the
test supports Abort, it is not guaranteed that the test will always come out with Test was aborted
by the user result event. This might occur because the multiple pass test may have been aborted
during the transition from one pass to another.
Tests that do not support the Abort feature will always run to completion. See Table 4-1 for a complete
list of tests that support any or all of the Abort, Suspend, and Quick Test features.
Scripting With the CLI
The PowerEdge Diagnostics CLI allows administrators to write batch programs or scripts to be executed
by the operating system. For an enterprise with many systems, an administrator could write a script that
runs diagnostic tests on system components to determine their health.
In many cases, the CLI allows a user with a very well-defined task in mind to retrieve information about
the system rapidly. You can redirect the diagnostic output to a file using the operating system’s
redirection feature.
Vista de página 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 39 40

Comentários a estes Manuais

Sem comentários