omconfig storage Commands 211
omconfig Blink Physical Disk
You can blink the light (light emitting diode or LED display) on one or more
physical disks attached to a controller. Use the following omconfig command
syntax to blink one or more physical disks.
Complete Syntax
omconfig storage pdisk action=blink controller=id
pdisk=<PDISKID>
where id is the controller ID. The <PDISK> variable specifies the physical
disk.
To obtain these values, type omreport storage controller to display the
controller IDs and then type omreport storage pdisk controller=ID to
display the IDs for the physical disks attached to the controller.
Example Syntax
In this example, to blink physical disk 0 on connector 0 of controller 1. On a SAS
controller, the physical disk resides in enclosure 2.
action=cancelclear controller=id pdisk=<PDISKID>
action=enabledevicewritecache controller=id pdisk=
<PDISKID>
action=disabledevicewritecache controller=id pdisk=
<PDISKID>
action=exportreliabilitylog controller=id pdisk=
<PDISKID>
action=convertraidtononraid controller=id pdisk=
<PDISKID>
action=convertnonraidtoraid controller=id pdisk=
<PDISKID>
Table 8-2. omconfig Physical Disk Commands
(continued)
Required Command Levels
(1, 2, 3)
Optional name=value pairs
Comentários a estes Manuais