Dell OpenManage Server Administrator Version 6.0.1 Guia do Utilizador Página 363

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 780
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 362
Memory Group 363
Table 15-6. Physical Memory Configuration Redundant Settings
Variable Name:
DellPhysicalMemoryConfigRedundantSettings
Data Type: Integer
Possible Data Values Meaning of Data Value
If set to 0 (zero) There are no redundant memory settings enabled.
unknown(1) Redundant settings are unknown.
The following redundant settings are mutually exclusive:
spareEnabled(2) Spare redundant memory feature is enabled.
mirrorEnabled(4) Mirror redundant memory feature is enabled.
raidEnabled(8) RAID redundant memory feature is enabled.
Table 15-7. Physical Memory Logging Capabilities
Variable Name:
DellPhysicalMemoryLoggingCapabilities
Data Type: Integer
Possible Data Values Meaning of Data Value
If set to 0 (zero) There are no logging capabilities.
unknown Capabilities(1) Logging capabilities are unknown.
The logging capabilities are:
enableCapable(2) Logging enable/disable using Simple Network
Management Protocol (SNMP) is supported.
book.book Page 363 Tuesday, January 27, 2009 12:37 PM
Vista de página 362
1 2 ... 358 359 360 361 362 363 364 365 366 367 368 ... 779 780

Comentários a estes Manuais

Sem comentários