210 Remote Flash BIOS Group
Remote Flash BIOS Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 11-1. Remote Flash BIOS State Capabilities Unique
Variable Name:
DellRemoteFlashBIOSStateCapabilitiesUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The remote flash BIOS’s capabilities are
unknown.
enableCapable(2) The remote flash BIOS can be disabled
(offline, a binary 0 value) or enabled (online,
a binary 1 value).
notReadyCapable(4) The remote flash BIOS can be set to
indicate not ready.
cancelCapable(8) Flash of BIOS can be canceled.
enableAndCancelCapable(10) Flash of BIOS can be enabled or canceled.
Table 11-2. Remote Flash BIOS State Settings
Variable Name:
DellRemoteFlashBIOSStateSettingsUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The remote flash BIOS’s capabilities are unknown.
enabled(2) The remote flash BIOS update is disabled (offline, a
binary 0 value) or enabled (online, a binary 1 value).
notReady(4) The remote flash BIOS’s state is not ready.
canceled(8) The remote flash BIOS has been canceled.
pending(16) The remote flash BIOS update is pending.
other(32) The remote flash BIOS state/setting is not one of
the previous values.
book.book Page 210 Tuesday, August 5, 2008 9:15 AM