Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Manual do Utilizador Página 103

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 316
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 102
omconfig: Managing Components Using the Instrumentation Service 103
attribute=
conredirect
setting=enabled |
disabled
enabled: Redirects the BIOS screen output
over serial port 1. Keyboard and text
output are redirected over serial port 2.
disabled: Turns off the BIOS console
redirection.
attribute=crab setting=enabled |
disabled
enabled: Enables BIOS console
redirection after system reboot.
disabled: Disables BIOS console
redirection.
NOTE: The attribute crab is valid only on
Dell PowerEdge
x
9
xx
systems.
attribute=cpuc1e setting=enabled |
disabled
enabled: Enables processor C1-E after
system reboot.
disabled: Disables processor C1-E after
system reboot.
attribute=cpuht setting=enabled |
disabled
enabled: Enables logical processor
hyperthreading.
disabled: Disables logical processor
hyperthreading.
attribute=cpuvt setting=enabled |
disabled
enabled: Enables virtualization.
disabled: Disables virtualization.
Table 4-3. BIOS Setup Settings on Systems Prior to PowerEdge
yx2x
Systems
(continued)
name=value pair 1
attribute=
name=value pair 2
setting=
Description
Vista de página 102
1 2 ... 98 99 100 101 102 103 104 105 106 107 108 ... 315 316

Comentários a estes Manuais

Sem comentários