Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
iDRAC.IPMILan
To configure IPMI over LAN of the system, use the objects in this group.
iDRAC.IPMILan.AlertEnable (Read or Write)
Description Enables or disables global email alerting.
Legal Values
0 — Disabled
1 — Enabled
Default Value 0 — Disabled
Write Privilege Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency None
iDRAC.IPMILan.CommunityName (Read or Write)
Description
Specifies the SNMP community name for traps.
Legal Values
String of up to 18 ASCII characters
Default Value
Public
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
iDRAC.IPMILan.Enable (Read or Write)
Description
Enables or disables the IPMI over LAN interface.
Legal Values
0 — Disabled
1 — Enabled
Default Value
0 — Disabled
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
278