FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PCI3006
Message Failed to get Link Tuning or FlexAddress data from iDRAC.
Detailed
Description
Either the BIOS or BMC/iDRAC firmware is out of date and does not support FlexAddress.
Recommended
Response Action
Update BIOS, and BMC/iDRAC firmware. If problem persists please contact customer support.
Category System Health
SubCategory PCI = PCI Device
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PCI3007
Message Link Tuning or FlexAddress data successfully obtained.
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory PCI = PCI Device
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
420
Vista de página 419
1 2 ... 415 416 417 418 419 420 421 422 423 424 425 ... 930 931

Comentários a estes Manuais

Sem comentários