RACADM Command Line Reference Guide for iDRAC7 1.30.30 and CMC 4.3

Página 2 - Notes, Cautions, and Warnings

cfgLdapEnable (Read/Write)...19

Página 3 - Contents

Exampleracadm krbkeytabupload -f c:\keytab\krbkeytab.tablclogDescription Allows you to export the lifecycle log history, view the lifecycle log for a

Página 4

NOTE: This parameter input is an integer. If an alphanumeric input is provided, then invalid subcommand syntax error is displayed.• -n — Specifies the

Página 5

NOTE: To view or export the lifecycle log you need Login to iDRAC permission only.Example• Display the number of records present in the Lifecycle Log:

Página 6

• racadm license delete -c <component>• racadm license replace -t 1• racadm license replace -u <username>-p <password> -f <licens

Página 7

Examples• View All License Information on System$racadm license viewiDRAC.Embedded.1 Status = OK Device = iD

Página 8

• Export license to a CIFS share specifying the entitlement ID, in this case abcdxyz :racadm license export -u admin -p passwd -f License.xml-l //192.

Página 9

ff00::/8 :: U 256 0 0 eth1Kernel IP routing tableDestination

Página 10

• Displays the statistics for the integrated NIC.$ racadm nicstatistics NIC.Integrated.1-1Total Bytes Received:0Total Bytes Transmitted:

Página 11

Reply from 2011:de11:bdc:194::31: time<1ms Reply from 2011:de11:bdc:194::31: time<1ms Ping statistics for 2011:de11:bdc:194::31: Packets: Sen

Página 12

Exampleracadm racdump=============================================================================== General System/RAC Information===================

Página 13

cfgChassisPowerCapBTU (Read/Write)...201cfgChassi

Página 14

<senType> <Num> <sensorName> <status> <AC-OK status>PWR 1 PS-1 Online OKPWR 2

Página 15

• To reset CMC:racadm racreset• To reset server 1:racadm racreset -m server-1• To reset servers 1 and 3:racadm racreset -m server-1 server-3• To force

Página 16

iDRAC only options:• -f — Force resetcfg. If any VFlash partition creation or formatting is in progress when this command is issued, iDRAC sends back

Página 17

• Monitor and Inventory all batteries connected to the controllerracadm raid get batteries --refkey <controller FQDDsseparated by comma>The abov

Página 18

The above command displays all fan keys connected to the enclosures referred as refkeys.racadm raid get fans --refkey <enclosure FQDDs separatedby

Página 19

Input• -c- Connect the image.• -d - Disconnect image.• -u - Username to access the network share.• -p- Password to access the network share.• -l - Ima

Página 20

• Deploy a remote image on iDRAC NFS share for all the servers: racadm remoteimage -c -a -l '192.168.0.180:/dev/floppy.img' -u root -p calvi

Página 21

• Get Power Status on iDRACracadm serveraction powerstatusServer Power Status: ON• Reseat blade 2 on CMC$ racadm serveraction -m server-2 reseat -fSer

Página 22

• -s — Power state of the host when the import operation completes. The parameters are "On" for powered ON and "Off" for powered O

Página 23

• —e — Enables to select existing or create new group for a member. The valid values are:– 0 — to create new group– 1 — to use existing groupNOTE: If

Página 24

cfgIpmiPetAlertDestIpAddr (Read/Write)...210cfgIpmi

Página 25

Legal value: chassisYou can obtain the same output if you do not include this option, as there is only one legal value.<assettag> is a maximum o

Página 26

• racadm setflexaddr -f A 1 Fabric A FlexAddress state set successfully• racadm setflexaddr -f idrac 1setledDescription Sets the state (blinking or no

Página 27

setniccfgDescription Sets the iDRAC IP address. It displays an error message if the requested operation could not be performed, or a success message i

Página 28

— mm is the month— dd is the day— hh is the hour— mm is the minutes— ss is the seconds— mmmmmm is the number of microseconds— s is a + (plus) sign or

Página 29

setslotnameDescription Displays the name and hostname (if available) of all 16 slots, or of a specified slot (indicated by the slot number) in the cha

Página 30

• -c — Sets the chassis name or location.Exampleracadm setsysinfo -c chassisname "Dell Rack System"The chassis name was set successfully.ssh

Página 31

options. <key index> must be between 1 to 4 or all on iDRAC.• -t <PK Key Text> - Key text for the SSH Public key.• -f <filename> - F

Página 32

2 = CA certificate for Directory Service3 = Custom signing certificateOutput Returns 0 when successful and a nonzero number when unsuccessful.Exampler

Página 33 - Introduction

• Uploading a PKCS file without any passphrase:racadm sslcertupload –t 3 –f <filename>• Uploading a PKCS file with a passphrase:racadm sslcertup

Página 34 - RACADM Syntax Usage

Organizational Unit (OU)Remote Access GroupCommon Name (CN) iDRAC Default certificateCommon Name (CN) iDRAC Default certificateValid From Jul 8 16:21:

Página 36 - Supported RACADM Subcommands

sslcsrgenDescription Generates and downloads a CSR file to the client’s local file system. The CSR can be used for creating a custom SSL certificate t

Página 37

1 = SSL key used to generate the server certificate• -f — Specifies the file name of the SSL key to be uploaded.Output Returns 0 when successful and a

Página 38

• -l — Network share location, can be either CIFS or NFS.• -f — Image file name.• -u — Username for the remote share access.• -p — Password for the re

Página 39 - Other Documents You May Need

• Enable the alert — racadm config -g cfgEmailAlert -o cfgEmailAlertEnable -i 1• Set the destination e-mail address —racadm config -g cfgEmailAlert -o

Página 40

This subcommand when executed performs the following:• Checks command syntax.• Verifies whether the required system resources are available.• Validate

Página 41 - RACADM Subcommand Details

• Verifies that the CMC acquires a Kerberos TGT.• Acquires user privileges from the Active Directory server.• Checks the time to acquire user privileg

Página 42

• View the current test trap settingsracadm getconfig -g cfgIpmiPet -i <index>where <index> is a number from 1 to 4testalertDescription Te

Página 43

To use this subcommand for CMC, you must have Administrator privilege and for iDRAC, you must have Execute Diagnostic Commands permission.Synopsisraca

Página 44

To use this subcommand, you must have Configure iDRAC permission.This option is applicable only to iDRAC.Synopsisracadm usercertupload -t <type>

Página 45

• racadm vflashsd statusvflashpartitionDescription Manages the partitions on the vFlash SD card.NOTE: To use this subcommand, you must have the iDRAC7

Página 46

cfgIPv6StaticEnable (Read or Write)...229cfg

Página 47 - <user name>

• Status of all existing partitions:racadm vflashpartition status -a• List all the existing partitions and its properties:racadm vflashpartition listv

Página 48

3iDRAC and CMC Property Database Group and Object DescriptionsThe iDRAC and CMC property database contains the configuration information for iDRAC and

Página 49

Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower ServersCMCifcRacManagedNodeOsYes Yes NocfgRacSecurityNo No YescfgRacVirtualYes Yes NocfgServ

Página 50

idRacInfoThis group contains display parameters to provide information about the specifics of iDRAC or CMC being queried. One instance of the group is

Página 51

Default for CMC CMCiDRAC Type (Read Only)Description Identifies the remote access controller type.Legal Values Product IDDefault For CMC: 9For 10G iDR

Página 52

cfgNicIPv4Enable (Read or Write)Description Enables or disables iDRAC or CMC IPv4 stack.Legal Values• 1 (TRUE)• 0 (FALSE)Default 0cfgNicSelection (Rea

Página 53

NOTE: For iDRAC Enterprise on Blade Servers, this object enables or disables the VLAN capabilities of iDRAC from CMC.This is Read only for iDRAC on Bl

Página 54

cfgDNSDomainNameFromDHCP (Read/Write)Description Specifies that iDRAC or CMC DNS domain name should be assigned from the network DHCP server.Legal Val

Página 55

Default For iDRAC: idrac-<service tag>For CMC: cmc-<service tag>cfgDNSRegisterRac (Read/Write)Description Registers the iDRAC or CMC name

Página 56

cfgDNSServersFromDHCP (Read/Write)Description Specifies if the DNS server IPv4 addresses should be assigned from the DHCP server on the network.For CM

Página 57

cfgSmartCard...

Página 58

cfgNicIpAddress (Read/Write)Description Specifies the static IPv4 address to be assigned to the RAC or CMC.NOTE: This parameter is only configurable i

Página 59

cfgNicUseDhcp (Read/Write)Description Specifies whether DHCP is used to assign the iDRAC or CMC IPv4 address. If this property is set to 1 (TRUE), the

Página 60

cfgNicStaticIPv4Enable (Read or Write)Description Enables or disables the IPv4 stack.Legal Values• 0 — Disabled• 1 — EnabledDefault 1 — EnabledNOTE: I

Página 61

cfgNicStaticGateway (Read or Write)Description Returns or sets the static IPv4 address.Legal Values Any Valid IPv4 addressDefault 192.168.0.120cfgDNSS

Página 62

NOTE: Microsoft Active Directory only supports Fully Qualified Domain Names (FQDN) of 64 characters or fewer length.Default NullcfgDNSStaticDomainName

Página 63

cfgRhostsFwUpdatePath (Read/Write)Description Specifies TFTP path where iDRAC or CMC firmware image file exists on the TFTP server. The TFTP path is r

Página 64

This object is applicable only for CMC.Legal Values A string representing a valid NTP server. For example, ntp2.ntp.net. At least one NTP server must

Página 65

cfgRhostsSyslogServer1 (Read/Write)Description Specifies the first of three possible remote syslog servers to store the RAC and SEL logs.This property

Página 66

cfgRhostsSyslogPowerLoggingIntervalDescription Specifies the power consumption collection/logging interval.This object is applicable only for CMC.NOTE

Página 67

For CMC, the index number is used to specify a unique group name. Only valid for indexed groups.Legal Values• For iDRAC: This parameter is populated b

Página 68

4 Database Objects With Get and Set Commands...247System.LCD...

Página 69

Clear Logs 0x00000008Execute Server Control Commands 0x00000010Access Virtual Console 0x00000020Access Virtual Media 0x00000040Test Alerts 0x00000080E

Página 70

cfgUserAdminUserName (Read/Write)Description The name of the user for this index. The user index is created by writing a string into this name field i

Página 71

Default 0cfgUserAdminIpmiSerialPrivilege (Read/Write)Description The maximum privilege on the IPMI LAN channel.This object is applicable only for iDRA

Página 72

cfgEmailAlertAddress (Read/Write)Description Specifies the destination email address for email alerts, for example, [email protected] Values E-m

Página 73

cfgSsnMgtRacadmTimeout (Read/Write)Description Defines the idle timeout in seconds for the Remote RACADM interface. If a remote RACADM session remains

Página 74

After the message is displayed, the system returns to the shell that generated the Secure Shell session.Legal Values• 0 (No timeout)• 60 – 10800NOTE:

Página 75

cfgSerialBaudRate (Read/Write)Description Sets the baud rate on iDRAC or CMC serial port.Legal Values• For iDRAC: 9600, 28800, 57600, 115200• For CMC:

Página 76

Configuration options: The value must start with the ^ character, and be followed by one of the characters— a-z, A-Z, [, ], \Legal value: String of up

Página 77 - <module

NOTE: The prompt counts as two characters.NOTE: The terminal emulator must be configured with the line wrap mode ON, if a terminal emulator is used.Le

Página 78

cfgSerialTelnetEnable (Read/Write) Description Enables or disables the Telnet console interface on iDRAC or CMC.Legal Values• 1 (TRUE)• 0 (FALSE)Defau

Página 79

System.Power.Max.LastWeek (Read Only)...256System.Pow

Página 80

cfgTrapsThis group displays information for and configures delivery of SNMP traps for a specific user.This object property is applicable only to CMC.

Página 81

cfgTrapsAlertDestIpAddr=cfgTrapsCommunityName=publiccfgRacTuningThis group is used to configure various iDRAC or CMC configuration properties, such as

Página 82

cfgRacTuneHttpPort (Read/Write)Description Specifies the port number to use for HTTP network communication with iDRAC or CMC.Legal Values 10 – 65535NO

Página 83

Default 192.168.1.1cfgRacTuneIpRangeMask (Read/Write)Description Standard IP mask values with left-justified bits. For example, 255.255.255.0.For CMC,

Página 84

cfgRacTuneIpBlkPenaltyTime (Read/Write)Description Defines the time span in seconds that session requests from an IP address with excessive failures a

Página 85

This object property is applicable only to iDRAC.Legal Values• 1 (TRUE)• 0 (FALSE)Default 1cfgRacTuneAsrEnable (Read/Write)Description Enables or disa

Página 86

• –420 (MST—Mountain Standard Time)• –360 (CST—Central Standard Time)• –300 (EST—Eastern Standard Time)For CMC: This object property is read only. Spe

Página 87

Default 0cfgRacTuneWebserverEnable (Read/Write)Description Enables or disables iDRAC or CMC web server. If this property is disabled, iDRAC or CMC is

Página 88

• 1 = Use Java PluginDefault 0 = Active X /Native PluginifcRacManagedNodeOsThis group contains properties that describe the managed server operating s

Página 89

cfgVirtualBootOnce (Read/Write)Description Enables or disables the Virtual Media Boot Once feature of iDRAC.If this property is enabled when the host

Página 90

iDRAC.ActiveDirectory.Enable (Read or Write)...265iDRAC.Acti

Página 91

Default 0cfgServerInfoFor iDRAC this group allows you to select the BIOS first boot device and provides the option to boot the selected device only on

Página 92

cfgServerFW (Read Only)Description Displays the server's iDRAC management firmware revision.This object is applicable only to CMC.Legal Values No

Página 93

cfgServerNic3MacAddress (Read Only)Description Displays the MAC address of the server NIC 3.This object is applicable only to CMC.Legal Values NoneDef

Página 94 - <FQDD >

cfgServerPowerBudgetAllocation (Read Only)Description Displays the current power allocation for the server.This object is applicable only to CMC.Legal

Página 95

NOTE: For a vFlash Partition to be configured as First Boot Device, it has to be attached first. When a detached / non-existent VFlash partition or a

Página 96

# cfgServerBmcMacAddress=00:21:9B:FE:5F:58# cfgServerNic1MacAddress=00:0D:56:B8:69:63170 CMC Property Database Group and Object Definitions# cfgServer

Página 97

The following sections provide information about the objects in the cfgActiveDirectory group.cfgADRacDomain (Read/Write)Description Active Directory D

Página 98

• 0 (Disable)Default 0cfgADSSOEnable (Read/Write)Description Enables or disables Active Directory single sign-on authentication on iDRAC.Legal Values•

Página 99

This object is applicable only to iDRAC.Legal Values A string of up to 254 ASCII characters representing a valid IP address or a fully qualified domai

Página 100

Exampleracadm getconfig -g cfgActiveDirectorycfgADEnable=1cfgADSCLEnable=0cfgADSSOEnable=0cfgADRacDomain=cfgADRootDomain=helpcfgADRacName=cfgADRacAuth

Página 101

iDRAC.IPMISerial.BaudRate (Read or Write)...274iDRAC.IPM

Página 102

• 0 (FALSE)Default 1cfgADDcSRVLookupEnable (Read/Write)Description Configures iDRAC to use pre‑configured domain controllers or to use DNS to find the

Página 103

cfgADGcSRVLookupEnable (Read/Write)Description Determines how the global catalog server is looked up. If using pre‑configured global catalog servers,

Página 104

cfgLdapServer (Read/Write)Description Configures the address of the LDAP Server. IPv4 and IPv6 are supported.NOTE: You can specify multiple servers by

Página 105

cfgLdapGroupAttribute (Read/Write)Description Specifies which LDAP attribute is used to check for group membership. This should be an attribute of the

Página 106

Default NullcfgLdapSearchFilter (Read/Write)Description A valid LDAP search filter. This is used if the user attribute cannot uniquely identify the lo

Página 107

This object is applicable only to CMC.Legal Values• 1 (true)• 0 (false)Default 0cfgLDAPSRVLookupDomainNameDescription Configures the domain name to be

Página 108

This object is applicable only for iDRAC.Legal Values An integer between 1 and 5Default <instance>cfgLdapRoleGroupDN (Read/Write)Description Thi

Página 109

Default 0cfgLocationRack (Read/Write)Description Indicates rack where server is located.Legal Values String of up to 128 ASCII charactersDefault 0cfgL

Página 110

Default <blank>cfgSSADRoleGroupDomain (Read/Write)Description Active Directory Domain in which the Role Group resides.Legal Values Any printable

Página 111

NOTE: You can configure any setting that is not preceded by the hash sign (#) in the output. To modify a configurable object, use the -o option.The fo

Página 112

Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates

Página 113

iDRAC.IPv6.Address12 (Read Only)...283iDR

Página 114

cfgChassisMinPower (Read Only)Description The minimum system input power consumption value (in watts) over the time since the value was last cleared.L

Página 115

cfgChassisPowerCapF (Read/Write)Description Indicates the maximum power consumption limit (in watts) for the entire chassis. Use cfgChassisPowerCapF w

Página 116

cfgChassisPowerCapFPercent (Read/Write)Description Indicates the power consumption limit as a percentage. The percentage is computed mathematically as

Página 117

cfgChassisMaxPowerConservationMode (Read/Write)Description Enables or disables maximum power conservation mode. When enabled, all servers are immediat

Página 118

cfgChassisInPowerServerAllocation (Read Only)Description Indicates (in watts) the cumulative power allocated to servers. There is no default as this p

Página 119 - <module>

cfgChassisPowerButtonEnable (Read/Write)Description Indicates if the chassis power button is enabled or disabled.Legal Values• 0 (disabled)• 1 (enable

Página 120

cfgIpmiSolThis group is applicable only for iDRAC and is used to configure the Serial Over LAN (SOL) capabilities of the system.The following sections

Página 121

cfgIpmiSolSendThreshold (Read/Write)Description Specifies the SOL threshold limit value and the maximum number of bytes to buffer before sending an SO

Página 122 - IPv4Address

cfgIpmiLanEncryptionKey (Read/Write)Description Specifies the IPMI encryption key.Legal Values A string of hexadecimal digits from 0 to 40 characters

Página 123

cfgIpmiPefThis group is applicable only for iDRAC and is used to configure the platform event filters available on the managed server.The event filter

Página 124

iDRAC.NIC...

Página 125

cfgIpmiPetThis group is applicable only for iDRAC and is used to configure platform event traps on the managed server.The following sections provide i

Página 126 - PK Key Text

cfguserdomainnameDescription Specifies the Active Directory user domain name.Legal Values A string of up to 254 ASCII charactersDefault <blank>c

Página 127

cfgServerPowerCapEnable (Read/Write)Description Enables or disables the user specified power budget threshold.This object is Read only for iDRAC Enter

Página 128

Default Maximum power consumption timestamp.cfgServerPowerConsumptionClear (Write Only)Description Clears the current recorded power statistics.This o

Página 129

cfgServerPowerLastHourAvg (Read Only)Description Displays the average power value during the last hour.This object is applicable only for iDRAC.Legal

Página 130

• HH = hour• MM=Minutes• SS = SecondsDefault Minimum power value during the last minute.cfgServerPowerLastHourMaxPower (Read Only)Description Displays

Página 131

where,• DD = Day of the week• MM = Month• Date = Date• YYYY = Year• HH = hour• MM = Minutes• SS = SecondsDefault Minimum power value during the last d

Página 132

cfgServerPowerLastWeekMinTime (Read Only)Description Displays the timestamp of minimum power value during the last week.This object is applicable only

Página 133 - <feature>

cfgServerPowerInstHeadroom (Read Only)Description Displays the difference between the available power and the current power consumption.This object is

Página 134

where,• DD = Day of the week• MM = Month• Date = Date• YYYY = Year• HH = hour• MM = Minutes• SS = SecondsDefault Timestamp of the current peak power c

Página 135

iDRAC.Security.CsrCommonName (Read or Write)...301iDRAC.Security.C

Página 136

cfgServerPowerPCIeAllocation (Read/Write)Description Amount of power allocated to the PCIe cards.This object is applicable for iDRAC Enterprise only f

Página 137

Use this object with the config or getconfig subcommands.To use this object property, you must have Chassis Configuration Administrator privilege.cfgA

Página 138

cfgServerPowerSupplyThis group is applicable only for iDRAC and contains information related to the power supplies. The following sections provide inf

Página 139

cfgServerPowerSupplyFwVer (Read Only)Description Displays the firmware version of the power supply unit, in the format x.xx.xxx.Legal Values A string

Página 140

NOTE: This object is applicable only for CMC.Legal Values A string representing a valid IPv6 address. For example, 2001:DB8:1234:5678:9ABC:DE11:C00C:B

Página 141 - Object Descriptions

• 0 (FALSE)Default• For iDRAC: 0• For CMC: 1cfgIPv6LinkLocalAddress (Read Only)Description The iDRAC IPv6 link local address.This object is applicable

Página 142

cfgIPv6Address6 (Read Only)Description The iDRAC IPv6 sixth address.This object is applicable only for iDRAC.Legal Values String representing a valid

Página 143

Default ::cfgIPv6Address12 (Read Only)Description The iDRAC IPv6 twelfth address.This object is applicable only for iDRAC.Legal Values String represen

Página 144

cfgIPv6DNSServer1 (Read/Write)Description Specifies the IPv6 DNS server address.NOTE: This property is used only if cfgIPv6DNSServersFromDHCP6 is set

Página 145

cfgIPv6StaticEnable (Read or Write)Description Enables or disables the static IPv6 stack.Legal Values• 0 — Disabled• 1 — EnabledDefault 0 — DisabledNO

Página 146

iDRAC.Telnet.Port (Read or Write)...310i

Página 147

cfgIPv6StaticDNSServersFromDHCP6 (Read or Write)Description Specifies the DNS server static IP addresses.Legal Values• 0 — DNS Server should be config

Página 148

cfgNicCurrentGatewayDisplays the static gateway for the CMC IP address.Description Displays the static gateway for the CMC IP address.Legal ValuesDefa

Página 149

cfgDNSCurrentServer2Description Displays the IP address for DNS server 2.Legal ValuesDefaultcfgDNSCurrentDomainNameDescription Displays the DNS domain

Página 150

cfgCurrentIPv6EnabledDescription Indicates whether IPv6 is enabled on the CMC. If the current property value is set to 0 (false), the remote network i

Página 151

cfgCurrentIPv6DNSServersFromDHCP6 Description Indicates whether the DNS server addresses are assigned from the DHCPv6 server.Legal ValuesDefaultcfgCur

Página 152

It is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers or CMC.cfgIpmiSerialBaudRate (Read/Write)Descr

Página 153

cfgIpmiSerialHandshakeControl (Read/Write)Description Enables or disables the IPMI terminal mode handshake control.Legal Values• 0 (FALSE)• 1 (TRUE)De

Página 154

• 3 (<CR>)• 4 (<LF-CR>)• 5 (<LF>)Default 1cfgIpmiSerialInputNewLineSequence (Read/Write)Description Specifies the input newline sequ

Página 155

cfgNetTuningThis group enables users to configure the advanced network interface parameters for the RAC NIC or CMC. When configured, the updated setti

Página 156

cfgNetTuningNicFullDuplex (Read/Write)Description Specifies the duplex setting for the RAC or CMC NIC. This property is used only if the cfgNetTuningN

Página 157

BIOS.BiosBootSettings...

Página 158

cfgSensorRedundancyCapabilities (Read Only)Description Returns the redundancy capabilities in the form of a bitmask. This bitmask allows the user to k

Página 159

cfgVFlashSDEnable (Read/Write)Description Enables or disables the vFlash SD card.NOTE: Disabling vFlashPartition by setting cfgVFlashSDEnable to 0 doe

Página 160

• UnknownDefault OKcfgVFlashSDWriteProtect (Read Only)Description Displays whether the physical write-protect latch on the vFlash SD card is enabled o

Página 161

cfgVFlashPartitionFlashOSVolLabelDescription Displays the label for the partition that is visible to the operating system.Legal Values An alphanumeric

Página 162

The following section provide information about the objects in the cfgLogging group:cfgLoggingSELOEMEventFilterEnable (Read/Write)Description Enables

Página 163

cfgRacSecCsrLocalityName (Read/Write)Description Specifies the CSR Locality (L).Legal Values A string of up to 254 characters.Default <blank>cfg

Página 164

cfgRacSecCsrKeySize (Read/Write)Description Specifies the SSL asymmetric key size for the CSRs.Legal Values 512, 1024, 2048Default 1024246

Página 165

4Database Objects With Get and Set CommandsThis chapter provides the database groups and objects that must be used with the get or set subcommands. Th

Página 166

• 256-System Watts• 512-Asset TagWrite Privilege Configure iDRAC and Configure UserLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency None

Página 167

Dependency NoneSystem.Location.DeviceSize (Read Only)Description Indicates server chassis size.Legal Values Values from 1 - 255Write Privilege Config

Página 168

BIOS.MemSettings.VideoMem (Read Only)...329BIOS.MiscSe

Página 169

Dependency NoneSystem.Location.Chassis.Slot (Read or Write)Description Indicates chassis slot.Legal Values Values from 1 - 255Write Privilege Configur

Página 170

Write Privilege Configure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneSystem.Power.Avg.LastWeek (Read Only)Description Ind

Página 171

System.Power.Cap.Btuhr (Read or Write)Description Represents the maximum power in BTU/Hr a device is allowed to consume. The device may throttle in or

Página 172

License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneSystem.Power.Cap.Percent (Read or Write)Description Represents the maximum power as

Página 173

License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneSystem.Power.EnergyConsumption.StarttimeStamp ( Read Only )Description Displays the

Página 174

Write Privilege Configure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneSystem.Power.Max.Amps.TimeStamp (Read Only)Descript

Página 175

System.Power.Max.LastHour (Read Only)Description Displays the maximum power value during the last hour.Legal Values Values from 1 - 65535Write Privile

Página 176

Dependency NoneSystem.Power.Max.Power.Timestamp (Read Only)Description Displays time of maximum power consumption.Legal Values String of up to 254 ASC

Página 177

Dependency NoneSystem.Power.Min.LastHour.Timestamp (Read Only)Description Indicates the timestamp of minimum power during the last hour.Legal Values

Página 178

System.Power.PFCEnable (Read or Write)Description Enables the power factor correction enable.NOTE: • This object is supported only for iDRAC on Rack a

Página 179

BIOS.ProcSettings.ProcBusSpeed (Read Only)...338BIOS.ProcSet

Página 180

Default 0System.Power.SupplyThis group provides information relating to the Power Supplies.This group is indexed from 1 to 4. If there are less than 4

Página 181

System.Power.Supply.[i].Status (Read Only)Description Displays the status of the power supply unit.Legal Values• 0 - absent• 1 - present and OK• 2 - f

Página 182

System.ServerOS.OSName (Read or Write)Description Displays the operating system name of the managed server.Legal Values String of up to 254 ASCII char

Página 183

LC.LCAttributes.PartConfigurationUpdate (Read or Write)Description Apply hardware configuration to the replaced part on part replacement.Legal Values

Página 184

Write Privilege Configure iDRACLicense Required iDRAC7 EnterpriseDependency NoneiDRAC.ActiveDirectory.DCLookupByUserDomain (Read or Write)Description

Página 185

iDRAC.ActiveDirectory.DomainController1 (Read or Write)Description FQDN that stores the address of the active directory domain controller 1.Legal Valu

Página 186

Write Privilege Configure iDRACLicense Required iDRAC7 EnterpriseDependency Cannot be enabled unless one of the following is configured:• IPv4.DNS1• I

Página 187

License Required iDRAC7 EnterpriseDependency NoneiDRAC.ActiveDirectory.RacDomain (Read or Write)Description Active Directory Domain in which iDRAC res

Página 188

iDRAC.ADGroup.Domain (Read or Write)Description Active Directory Domain in which the Role Group resides.Legal Values String of up to 254 ASCII charact

Página 189

iDRAC.EmailAlertUse the objects in this group to configure e-mail alerting capabilities.iDRAC.EmailAlert.Address (Read or Write)Description Specifies

Página 190

BIOS.SataSettings.SataPortFCapacity (Read Only)...348BIOS.SataSett

Página 191

Dependency NoneiDRAC.Info.Description (Read Only)Description Text description of the iDRAC.Legal Values String of up to 255 ASCII charactersWrite Priv

Página 192

Write Privilege Configure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.IPBlockingUse the objects in this group to con

Página 193

License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.IPBlocking.RangeAddr (Read or Write)Description Specifies the acceptable IPv4

Página 194

License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.IPMILan.CommunityName (Read or Write)Description Specifies the SNMP community

Página 195

iDRAC.IPMISerialUse the objects in this group to configure the IPMI serial interface.NOTE: This is supported only for rack and tower systems.iDRAC.IPM

Página 196

iDRAC.IPMISerial.DeleteControl (Read or Write)Description Enables or disables delete control on the IPMI serial interface.Legal Values• 0 — Disabled•

Página 197

iDRAC.IPMISerial.InputNewLineSeq (Read or Write)Description Specifies the input new line sequence for the IPMI serial interface.Legal Values• 1- Enter

Página 198 - <blank>

iDRAC.IPMISOL.AccumulateInterval (Read or Write)Description Specifies the typical amount of time that iDRAC waits before transmitting a partial SOL ch

Página 199

iDRAC.IPMISOL.SendThreshold (Read or Write)Description Specifies the SOL threshold limit value and the maximum number of bytes to buffer before sendin

Página 200

iDRAC.IPv4.DNS2 (Read or Write)Description IPv4 address for DNS Server 2.Legal Values Valid IPv4 AddressWrite Privilege Configure iDRACLicense Require

Página 201

BIOS.SysProfileSettings.ProcTurboMode (Read or Write)...358BIOS.SysProfileSet

Página 202

iDRAC.IPv4.Netmask (Read or Write)Description The subnet mask used for the iDRAC IPv4 address.Legal Values Valid IPv4 netmaskWrite Privilege Configure

Página 203

iDRAC.IPv4Static.Gateway (Read or Write)Description iDRAC static IPv4 gateway. This address can be configured even when DHCP is enabled.Legal Values V

Página 204

iDRAC.IPv6.Address 5 (Read Only)Description iDRAC IPv6 fifth address.Legal Values Valid IPv6 AddressWrite Privilege Configure iDRACLicense Required iD

Página 205

iDRAC.IPv6.Address1 (Read or Write)Description iDRAC IPv6 Address.Legal Values Valid IPv6 AddressWrite Privilege Configure iDRACLicense Required iDRAC

Página 206

iDRAC.IPv6.Address14 (Read Only)Description iDRAC IPv6 fourteenth address.Legal Values Valid IPv6 AddressWrite Privilege Configure iDRACLicense Requir

Página 207

License Required iDRAC7 Express or iDRAC7 EnterpriseDependency Cannot be set unless IPv6.DNSFromDHCP6 is disabled.iDRAC.IPv6.DNS2 (Read or Write)Descr

Página 208

iDRAC.IPv6.LinkLocalAddress (Read or Write)Description iDRAC IPv6 Link Local Address.Legal Values Valid IPv6 AddressWrite Privilege Configure iDRACLic

Página 209

iDRAC.IPv6Static.DNS2 (Read or Write)Description Statically configurable DNS Server 2.Legal Values Valid IPv6 AddressWrite Privilege Configure iDRACLi

Página 210

iDRAC.IPv6URL.URL (Read Only)Description iDRAC IPv6 URL String of format 'https://[ipv6 address]:<port number>'Legal Values IPv6 URL S

Página 211

iDRAC.LDAP.CertValidationEnable (Read or Write)Description Controls certificate validation during SSL handshake.Legal Values• 0 — Disabled• 1 — Enable

Página 212

NIC.FCoEConfiguration.MTUParams (Read or Write)...369NIC.FCoEGenParam

Página 213

iDRAC.LDAP.Port (Read or Write)Description Port of LDAP over SSL.Legal Values Integer values from 1- 65535Write Privilege Configure iDRACLicense Requi

Página 214

iDRAC.LDAPRoleGroup.DN (Read or Write)Description This is the Domain Name of the group.Legal Values String of up to 1024 ASCII charactersWrite Privile

Página 215

Dependency NoneiDRAC.LoggingiDRAC. Logging Manages the ability to configure iDRACiDRAC.Logging.SELOEMEventFilterEnable (Read or Write)Description Enab

Página 216

iDRAC.NIC.DedicatedNICScanTime (Read or Write)Description Wait time for the iDRAC to switch from dedicated mode to shared mode.Legal Values Integral v

Página 217

iDRAC.NIC.DNSRacName (Read or Write)Description The iDRAC name.Legal Values String of up to 63 ASCII charactersWrite Privilege Configure iDRACLicense

Página 218

iDRAC.NIC.Failover (Read or Write)Description Enables or disables failover for idrac to switch from shared to dedicated.Legal Values• 0- None• 2- LOM1

Página 219

Write Privilege Configure iDRACLicense Required iDRAC7 Express (for Blades) or iDRAC7 EnterpriseDependency NoneiDRAC.NIC.SharedNICScanTime (Read or Wr

Página 220

NOTE: This object is applicable only to iDRAC on Racks and Towers.Legal Values Integral values from 1 - 4069Write Privilege Configure iDRACLicense Req

Página 221

iDRAC.NTPConfigGroupUse the objects in this group to configure the properties of NTP server.iDRAC.NTPConfigGroup.NTP1 (Read or Write)Description Confi

Página 222

iDRAC.NTPConfigGroup.NTPMaxDist (Read or Write)Description NTP Maximum DistanceLegal Values Integral values from 1 to 128Write Privilege Configure iDR

Página 223

ContentsNotes, Cautions, and Warnings...21 Introductio

Página 224

NIC.IscsiInitiatorParams.IscsiInitiatorPrimDns (Read or Write)...379NIC.IscsiInitiato

Página 225

iDRAC.RacadmUse the objects in this group to manage Remote RACADM connection settings.iDRAC.Racadm.Enable (Read or Write)Description Enables or disabl

Página 226

iDRAC.RFS.AttachMode (Read or Write)Description RFS Media attach mode.Write Privilege Configure iDRACLegal Values• 0- Attach• 1- Auto AttachLicense Re

Página 227

iDRAC.Security.CsrEmailAddr (Read or Write)Description Specifies the CSR email address.Legal Values Valid email address string of up to 254 ASCII char

Página 228

License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.Security.CsrStateName (Read or Write)Description Specifies the CSR State Name

Página 229

iDRAC.Serial.Enable (Read or Write)Description Enables or disables the iDRAC serial console interface.Legal Values• 0 — Disabled• 1 — EnabledWrite Pri

Página 230

NOTE: This is supported only for rack and tower systems.iDRAC.SerialRedirection.Enable (Read or Write)Description Enables or disables the console for

Página 231

Write Privilege Configure iDRAC and Configure UserLicense Required iDRAC7 EnterpriseDependency ActiveDirectory.SSOEnable has to be disablediDRAC.SNMPT

Página 232

License Required NoneDependency NoneiDRAC.SNMP.SNMPProtocol (Read or Write)Description Specified the SNMP protocol.Legal Values• 0- All• 1- SNMPv3Writ

Página 233

Write Privilege Configure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.SSH.Timeout (Read or Write)Description Defines

Página 234

Dependency NoneiDRAC.SysLog.Server1 (Read or Write)Description Name of remote syslog server 1.Legal Values String of up to 63 ACSII charactersWrite Pr

Página 235

NIC.VndrConfigGroup.iSCSIOffloadSupport (Read Only)...388NIC.VndrConfigGro

Página 236

iDRAC.Telnet.Enable (Read or Write)Description Enables or disables Telnet.Legal Values• 0 — Disabled• 1 — EnabledWrite Privilege Configure iDRACLicens

Página 237

iDRAC.TuningThe objects in this group enable you to manage iDRAC tuning and configuration parameters.iDRAC.Tuning.DefaultCredentialWarning (Read or Wr

Página 238

• 1- EnabledWrite Privilege Configure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.UserDomainThe objects in this grou

Página 239

License Required iDRAC7 Express or iDRAC7 EnterpriseDependency Both user name and password must be configured prior to setting this object.iDRAC.Users

Página 240

Write Privilege Configure iDRAC and Configure UserLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.Users.SNMPv3Enable (Read or

Página 241

Dependency NoneiDRAC.VirtualConsoleThe objects in this group enable you to manage virtual console configuration parameters of iDRAC.iDRAC.VirtualConso

Página 242

• 1 — EnabledWrite Privilege Configure iDRACLicense Required iDRAC7 Express (For Blades) or iDRAC7 EnterpriseDependency NoneiDRAC.VirtualConsole.MaxSe

Página 243

iDRAC.VirtualMediaThe objects in this group enable you to manage virtual media configuration parameters of iDRAC.iDRAC.VirtualMedia.Attached (Read or

Página 244

iDRAC.WebServer.Enable (Read or Write)Description Enables or disables iDRAC WebServer.Legal Values• 0 — Disabled• 1 — EnabledWrite Privilege Configure

Página 245

Write Privilege Configure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.BiosBootSettingsYou can manage the BIOS boot se

Página 247 - System.LCD

Dependency Read Only if BootMode is set to UEFIBIOS.BiosBootSettings.UefiBootSeq (Read or Write)Description UEFI boot sequenceLegal Values NoneWrite P

Página 248 - System.Location

BIOS.IntegratedDevices.EmbNic2 (Read or Write)Description Enables or disables the operating system interface of the embedded NIC2.Legal Values• Enable

Página 249

BIOS.IntegratedDevices.EmbNic4 (Read or Write)Description Enables or disables the operating system interface of the embedded NIC4.Legal Values• Enable

Página 250 - System.Power

License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.IntegratedDevices.IntegratedRaid (Read or Write)Description Enables or disable

Página 251

Dependency Read Only if 'InternalSdCard' is set to 'Off'.BIOS.IntegratedDevices.InternalUsb (Read or Write)Description Enable or d

Página 252

BIOS.IntegratedDevices.SriovGlobalEnable (Read or Write)Description Enables or disables BIOS configuration of Single Root I/O Virtualization (SR-IOV)

Página 253

• MirrorMode• AdvEccMode• SpareWithAdvEccModeWrite Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.Mem

Página 254

BIOS.MemSettings.MemVolt (Read or Write)Description Sets the DIMM voltage selection.Legal Values• AutoVolt• Volt135V• Volt15VWrite Privilege Server Co

Página 255

• ValidWrite Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.MemSettings.RedundantMemInUse (Read Only)

Página 256

Dependency NoneBIOS.MemSettings.SysMemType (Read Only)Description Indicates the current type of main memory installed in the system.Legal Values NoneW

Página 257

1IntroductionThis document provides information about the RACADM subcommands, supported RACADM interfaces, and property database groups and object def

Página 258

BIOS.MiscSettings.ErrPrompt (Read or Write)Description Enables or disables the F1 and F2 prompt on error.Legal Values• Enabled• DisabledWrite Privileg

Página 259

Dependency NoneBIOS.OneTimeBootYou can manage the one time boot settings using the objects in this group.BIOS.OneTimeBoot.OneTimeBootMode (Read or Wri

Página 260 - System.Power.Supply

Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency Read Only if OneTimeBootModeis not set to OneTimeHddSeqBI

Página 261 - System.ServerOS

• DisabledWrite Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.ProcSettings.DcuStreamerPrefetcher (Re

Página 262 - LC.LCAttributes

BIOS.ProcSettings.Proc1Brand (Read Only)Description Provides the processor brand name.Legal Values NoneWrite Privilege Server ControlLicense Required

Página 263

Dependency NoneBIOS.ProcSettings.Proc2Brand (Read Only)Description Provides the processor brand name.Legal Values NoneWrite Privilege Server ControlLi

Página 264

Dependency NoneBIOS.ProcSettings.Proc3Brand (Read Only)Description Brand text provided by the processor manufacturer.Legal Values NoneWrite Privilege

Página 265

Dependency NoneBIOS.ProcSettings.Proc4Brand (Read Only)Description Brand text provided by the processor manufacturer.Legal Values NoneWrite Privilege

Página 266

Dependency NoneBIOS.ProcSettings.Proc64bit (Read Only)Description Specifies whether the installed processor(s) support 64-bit extensions.Legal Values

Página 267

• 12• 14• 16Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.ProcSettings.ProcCoreSpeed (Read Onl

Página 268

Supported RACADM InterfacesThe RACADM command-line utility provides a scriptable interface that allows you to locally or remotely configure your Remot

Página 269

BIOS.ProcSettings.ProcHpcMode (Read or Write)Description Configure processor's HPC mode.Legal Values• Enabled• DisabledWrite Privilege Server Con

Página 270

Dependency NoneBIOS.ProcSettings.ProcSoftwarePrefetcher (Read or Write)Description Enables or disables the hardware prefetcher for considering softwar

Página 271

Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.ProcSettings.RtidSetting (Read or Write)Descript

Página 272

BIOS.SataSettings.eSataPort1Capacity (Read Only)Description Displays the total capacity of a hard-disk drive.Legal Values NoneWrite Privilege Server C

Página 273

License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SataSettings.SataPortADriveType (Read Only)Description Indicates type of devic

Página 274

BIOS.SataSettings.SataPortBDriveType (Read Only)Description Indicates type of device attached to this SATA port.Legal Values NoneWrite Privilege Serve

Página 275

License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SataSettings.SataPortCModel (Read Only)Description Displays the drive model of

Página 276

BIOS.SataSettings.SataPortDDriveType (Read Only)Description Indicates type of device attached to this SATA port.Legal Values NoneWrite Privilege Serve

Página 277

License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SataSettings.SataPortEModel (Read Only)Description Displays the drive model of

Página 278

BIOS.SataSettings.SataPortFModel (Read Only)Description Displays the drive model of the selected device.Legal Values NoneWrite Privilege Server Contro

Página 279

Remote RACADMracadm -r <racIpAddr> -u <username> -p <password> getconfig -g <groupname> [-o<objectname>] [-i <indexnu

Página 280

License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SataSettings.SataPortH (Read or Write)Description Sets the drive type of the s

Página 281

BIOS.SerialCommSettings.ConTermType (Read or Write)Description Configures the remote console's terminal type.Legal Values• Vt100Vt220• AnsiWrite

Página 282

Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SerialCommSettings.SerialComm (Read or Write)Des

Página 283

Dependency NoneBIOS.SlotDisablement.Slot2 (Read or Write)Description Control the configuration of the card installed in slot 2.Legal Values• Enabled•

Página 284

Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SlotDisablement.Slot6 (Read or Write)Description

Página 285

BIOS.SysInformation.SystemBiosVersion (Read Only)Description Provides the current revision of the system BIOS firmware.Legal Values NoneWrite Privileg

Página 286

Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SysProfileSettingsUse the objects in this group

Página 287

• DisabledWrite Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SysProfileSettings.MemRefreshRate (Rea

Página 288

BIOS.SysProfileSettings.ProcCStates (Read or Write)Description Enables or disables the processor C-States.Legal Values• Enabled• DisabledWrite Privile

Página 289

BIOS.SysProfileSettings.SysProfile (Read or Write)Description Sets the System Profile to Performance Per Watt (DAPC), Performance Per Watt (OS) Perfor

Página 290

Supported RACADM SubcommandsThe following table provides the list of RACADM subcommands and their corresponding interface support. For detailed inform

Página 291

Dependency NoneBIOS.SysSecurity.AcPwrRcvryUserDelay (Read Only)Description Controls the user defined AC Recovery Delay.Legal Values NoneWrite Privileg

Página 292

• UnlockedWrite Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SysSecurity.PwrButton (Read or Write)D

Página 293

• Up to 32 characters including whitespace.• Contain numbers 0 through 9.• Only lower case alphabets are accepted.• Special characters accepted are +,

Página 294

• OnWrite Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SysSecurity.TpmActivation (Read or Write)Des

Página 295

NIC.DCBSettingsThe following section provides information about the objects in the NIC.DCBSettings group.NIC.DCBSettings.CongestionNotification (Read

Página 296

• UnavailableWrite Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneNIC.DeviceLevelConfigUse the objects in

Página 297

Dependency NoneNIC.FCOECapabilitiesThe following section provides information about the objects in the NIC.FCOECapabilities group.NIC.FCOECapabilities

Página 298

NIC.FCOECapabilities.MaxNumberExchanges (Read Only)Description Indicates the maximum number of exchanges supported.Legal Values NoneWrite Privilege Se

Página 299

• UnavailableWrite Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneNIC.FCoEConfigurationThe following secti

Página 300

NIC.FCoEConfiguration.FirstFCoEWWPNTarget (Read or Write)Description World Wide Port Name (WWPN) of the first FCoE storage target.Legal Values NoneWri

Página 301

Subcommand iDRAC on Blade ServersiDRAC on Rack and Tower ServersCMCgetioinfo No No No No No No Yes Yesgetkvminfo No No No No No No Yes Yesgetled Yes Y

Página 302

NIC.FCoEGenParams.FCoEFabricDiscoveryRetryCnt (Read or Write)Description Retry count for FCoE fabric discovery.Legal Values Values from 0 - 60Write Pr

Página 303

NIC.FCoEGenParams.FCoETgtBoot (Read or Write)Description Enables the FCoE initiator to boot system to the FCoE target.Legal Values• Enabled• DisabledW

Página 304

NIC.GlobalBandwidthAllocationThe following section provides information about the objects in the NIC.GlobalBandwidthAllocation group.NIC.GlobalBandwid

Página 305

Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency Not Available if 'VndrConfigGroup.iSCSIBootSupport&a

Página 306

License Required iDRAC7 Express or iDRAC7 EnterpriseDependency Not Available if 'VndrConfigGroup.iSCSIBootSupport' is Unavailable.NIC.IscsiF

Página 307

NIC.IscsiGenParams.DhcpVendId (Read or Write)Description Control what Vendor ID is presented to the DHCP service.Legal Values String of upto 255 ASCII

Página 308

License Required iDRAC7 Express or iDRAC7 EnterpriseDependency Not Available if 'VndrConfigGroup.iSCSIBootSupport' is Unavailable.NIC.IscsiG

Página 309

Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency Not Available if 'IscsiGenParams.IpVer' is set

Página 310

NIC.IscsiInitiatorParams.IscsiInitiatorChapPwd (Password)Description Set the iSCSI initiator Challenge-Handshake Authentication Protocol (CHAP) secret

Página 311

NIC.IscsiInitiatorParams.IscsiInitiatorPrimDns (Read or Write)Description Specifies the Primary DNS IP address of the iSCSI initiator.Legal Values Str

Página 312

Subcommand iDRAC on Blade ServersiDRAC on Rack and Tower ServersCMCracreset Yes Yes Yes Yes Yes Yes Yes Yesracresetcfg Yes Yes Yes Yes Yes Yes Yes Yes

Página 313

NIC.IscsiSecondaryDeviceParams.SecondaryDeviceMacAddr (Read or Write)Description Specifies the MAC address of a secondary iSCSI boot adapter for redun

Página 314

• DisabledWrite Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency Not available if 'VndrConfigGroup.iSCSIBoo

Página 315

Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency Not available if 'VndrConfigGroup.iSCSIBootSupport&a

Página 316

NIC.NICConfig.LnkSpeed (Read or Write)Description Specifies the port speed used for the selected boot protocol.Legal Values• AutoNeg• 10Mbps Half• 10M

Página 317

License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneNIC.NICConfig.WakeOnLanLnkSpeed (Read or Write)Description Select the port speed us

Página 318

NIC.NICPartitioningConfig.NumberPCIEFunctionsSupported (Read Only)Description Indicates the number of physical PCIe functions supported on this port.L

Página 319 - BIOS.BiosBootSettings

License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneNIC.VndrConfigGroup.DeviceName (Read Only)Description Indicates the official produc

Página 320 - BIOS.IntegratedDevices

NIC.VndrConfigGroup.FCoEOffloadSupport (Read Only)Description Indicates whether FCoE Offload capability is supported.Legal Values NoneWrite Privilege

Página 321

License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneNIC.VndrConfigGroup.ISCSIMacAddr (Read Only)Description Indicates the permanent MAC

Página 322

NIC.VndrConfigGroup.MacAddr (Read Only)Description Indicates the permanent MAC address assigned during manufacturing.Legal Values String of up to 17 c

Página 323

Subcommand iDRAC on Blade ServersiDRAC on Rack and Tower ServersCMCusercertviewYes Yes Yes Yes Yes Yes No NovflashsdYes Yes Yes Yes Yes Yes No Novflas

Página 324

Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneNIC.VndrConfigGroup.OSBMCManagementPassThrough (Read

Página 325 - BIOS.MemSettings

NIC.VndrConfigGroup.RXFlowControl (Read Only)Description Indicates whether Receive (RX) Flow control capability is supported.Legal Values NoneWrite Pr

Página 326

NIC.VndrConfigGroup.TXFlowControl (Read Only)Description Indicates whether Transmit (TX) Flow Control capability is supported.Legal Values NoneWrite P

Página 327

NIC.VndrConfigGroup.VirtualLinkControl (Read or Write)Description Indicates whether Virtual Link Control capability is supported.Legal Values NoneWrit

Página 328

License Required iDRAC7 Express or iDRAC7 EnterpriseDependency None394

Página 331 - BIOS.OneTimeBoot

2RACADM Subcommand DetailsThis section provides detailed descriptions of the RACADM subcommands including the syntax and valid entries.Guidelines to Q

Página 332 - BIOS.ProcSettings

NOTE: An empty string may be specified as either "" (using double quotes) or '' (using single quotes)."?"and "?<

Página 333

-c : show chassis information-A : do not show headers or labels-4 : show CMC IPv4 information-6 : show CMC IPv6 informationhelp and help <subcomman

Página 334

IP Address HW Type Flags HW Address Mask Device192.168.1.1 0x1 0x2 00:00:0C:07:AC:0F * eth0autocompleteDescriptionDisplays all the available racadm co

Página 335

Inputracadm> cd <object>Output Use the command to execute object related get or setcommands.Example• Example 1: To execute all system related

Página 336

To use this subcommand, you must have Chassis Control Administrator privilegeSynopsisracadm chassisaction [-m <module>] <action>Input• -m

Página 337

closessnDescription Closes a communication session on the device. Use getssninfo to view a list of sessions that can be closed using this command.To u

Página 338

To use this subcommand, you must have Administrator privilege.NOTE: This command is valid only in redundant CMC environments. For more information, se

Página 339

• -c — The -c, or check option, is used with the config subcommand and allows the user to parse the .cfg file to locate syntax errors. If errors are f

Página 341

Input -b — Connects to the switch or console using the binary mode. This is an optional argument; a server or a switch must be present.NOTE: If you us

Página 342 - BIOS.SataSettings

This option is applicable only for iDRAC.To use this subcommand, you must have Clear Logs or Execute Debug Commands permission.NOTE: If a coredumpdele

Página 343

• -u root — Indicates that the <password> is supplied for the root user on the server or switch. Root is a constant parameter, the only value th

Página 344

To use this subcommand with the get and test option, you must have Administrator privilege.This subcommand is applicable only for iDRAC.Synopsisracadm

Página 345

• -r — Event generation interval. This is applicable only to the temperature statistics subcategory - tmps. You can use this option as a stand-alone o

Página 346

featureDescription Displays all active chassis features. The information displayed includes feature name, date activated, and the serial number of the

Página 347

Output• No feature card inserted — Action: Check the CMC to verify that the SD card was properly inserted. In a redundant CMC configuration, make sure

Página 348

at any time. In addition, the fwupdate subcommand may only update one or more devices of a single kind at a time.To use this subcommand for CMC you mu

Página 349

Input• -u — For iDRAC: The update option performs a checksum of the firmware update file and starts the actual update process. This option may be used

Página 350 - BIOS.SerialCommSettings

NOTE: iDRAC7 targets are not supported from CMC. Use the CMC GUI to update iDRAC7 targets from CMC.CMC version 3.00 accepts IPv4, IPv6, or fully quali

Página 351

cfgNicIPv4Enable (Read or Write)...145cf

Página 352 - BIOS.SlotDisablement

NOTE: For CMC, these commands specifically apply to an active-CMC update.The following table describes the firmware update method supported for each i

Página 353

• <object> — Specifies the object name of the value to be read.• <index> — Specifies where FQDD Alias's or Groups need to be indexed.

Página 354 - BIOS.SysInformation

<module> configuration completed successfully.Example• Get the configured storage array properties from server-3racadm getarraycfg -m server-3•

Página 355

Input• -f — The -f <filename> option directs getconfig to write the entire iDRAC configuration to a configuration file. This file can be used fo

Página 356 - BIOS.SysProfileSettings

racadm getconfig -u root• Displays the user group instance at index 2 with verbose information for the property values.racadm getconfig -g cfgUserAdmi

Página 357

<Server#> <Presence> <DC1 Type> <DC1 State> <DC2 Type> <DC2 State>server-4 Present None N/A Gigabit EthernetOKserv

Página 358

server-13 Not Present None Noneserver-14 Not Present None Noneserver-15 Not Present None Noneserver-16 Not Present None NonegetflexaddrDescription Di

Página 359 - BIOS.SysSecurity

9 Enabled Not Present10 Enabled Extension(2)11 Enabled Not Present12 Enabled Not Present13 Enabled Extension(5)14 Enabled Not Present15 Enabled Not Pr

Página 360

getfanreqinfoDescription Displays fan speed request for Servers and Switches in percent (%).To use this subcommand, you must have CMC Login User privi

Página 361

14 SLOT-14 PowerEdgeM600ON Present 3315 SLOT-15 N/A N/A Not Present N/A16 SLOT-16 N/A Extension(8) N/A N/ASwitch Module Fan Request Table<Slot#>

Página 362

cfgRhostsSyslogServer1 (Read/Write)...157cfgRh

Página 363

<IO Name> <Name> <Type> <Presence> <Fan Request%>Switch-1 Dell Ethernet Pass-ThroughGigabit EthernetPresent 30Switch-

Página 364 - NIC.DCBSettings

getkvminfoDescription Displays iKVM module information.To use this subcommand, you must have CMC Login User privilege.Synopsisracadm getkvminfoExample

Página 365 - NIC.DeviceLevelConfig

getmacaddressDescription Displays the MAC/WWN addresses for all modules or for a specified module.To use this subcommand, you must have CMC Login User

Página 366 - NIC.FCOECapabilities

00:11:43:FD:B7:2C00:11:43:FD:B7:2Dracadm getmacaddress<Name> <Presence> <BMC MAC Address><NIC1 MAC Address><NIC2 MAC Addres

Página 367

Switch-3 Present N/A 00:00:00:00:00:00N/ASwitch-4 Present N/A 00:00:00:00:00:00N/ASwitch-5 Present N/A 00:05:1E:08:EB:0BN/ASwitch-6 Not Present N/A N/

Página 368 - NIC.FCoEConfiguration

Server-4-B Gigabit EthernetNot Present Not InstalledNot InstallediSCSI Present Not InstalledNot InstalledServer-4-C Fibre Channel 4Present Not Install

Página 369 - NIC.FCoEGenParams

Server-13-A Gigabit EthernetPresent 00:18:8B:FF:45:2600:18:8B:FF:A9:F200:18:8B:FF:A9:F4iSCSI Present 00:18:8B:FF:A9:F300:18:8B:FF:A9:F5Server-13-B Gig

Página 370

Switch-6 N/A Not Present N/A N/A N/AgetmodinfoDescription Displays configuration and status information for all modules or a specified module (server,

Página 371 - NIC.FrmwImgMenu

Switch-2 Not Present N/A N/A N/ASwitch-3 Not Present N/A N/A N/ASwitch-4 Not Present

Página 372 - NIC.IscsiFirstTgtParams

IPv4 settings:NIC Enabled = 1IPv4 Enabled = 1DHCP Enabled = 1IP Address = 10.35.0.64Subnet Mask = 255.255.255.0Gateway = 10.35

Página 373

cfgTrapsIndex (Read Only)...

Página 374 - NIC.IscsiGenParams

getpbinfoDescription Displays power budget status information.To use this subcommand, you must have CMC Login User privilege.Synopsisracadm getpbinfoE

Página 375

9 SLOT-09 N/A N/A 5 N/A 10 SLOT-10 Extension(2) N/A 5 N/A 11 SLOT-11 N/A

Página 376

Performance = 7000 W (6130 BTU/hr)Redundancy Policy = NoneDynamic PSU Engagement Enabled = No[Power Budgeting]

Página 377 - NIC.IscsiInitiatorParams

Message Arg 2 = 10.92.68.245FQDD = iDRAC.Embedded.1 Example• Display the starting record and the number of records.racadm getraclog -s 10 -c 2• Displ

Página 378

getredundancymodeDescription Displays the redundancy status (Redundant or Non-Redundant) of the CMC.To use this subcommand, you must have CMC Login Us

Página 379

For CMC:racadm getsensorinfo<senType> <Num> <sensorName> <status> <reading><units> <lc> <uc>FanSpeed

Página 380 - NIC.IscsiSecondTgtParams

System Board Fan6B RPM Ok 5160 RPM 720 RPM NA System Board Fan7B RPM Ok 3840 RPM 720 RP

Página 381

System Board CMOS Battery Ok Present NA NA Sensor Type : PERFOMANCE<Sensor Name> <Stat

Página 382 - NIC.NICConfig

11 SLOT-11 12 SLOT-12 13 SLOT-13 14 SLOT-14 15 SLOT-15 16 SLOT-16racadm getslotname -i 1Webserver-1getssnin

Página 383

Exampleracadm getsvctaggetsysinfoDescription Displays information related to iDRAC, managed system, and watchdog configuration.NOTE: The local racadm

Página 385

Current IP Gateway = :: Autoconfig = 1Link Local IP Address = fe80::224:e8ff:fe2e:c5d3/255Current IP Address 2 = ::Current IP A

Página 386

System Revision = I System BIOS Version = 0.2.3 BMC Firmware Version = 0.17 Service Tag = 48192 Host Name

Página 387

Input• (none) - Displays the version information for all targets or devices.• -m <module> - Specifies the module or device for which you want to

Página 388

server-2 PowerEdgeM805server-5 1.0.0 PowerEdgeM710racadm getversion -b<Server> <BIOS Version> <Blade Type>server-1 2.0.0 PowerEdgeM6

Página 389

hwinventoryDescription Allows you to display or export current internal hardware inventory or shipped hardware inventory by device.To use this subcomm

Página 390

Sync Time: 0x0000Product Name: QLogic CNA Gigabit Ethernet-B8:AC:6F:B3:BF:1Permanent MAC Address:

Página 391

Hard Zone Address: 0Hard Zone Enable: DisabledFC Tape Enable: Dis

Página 392

ifconfigDescription Displays the contents of the network interface table.To use this subcommand for CMC, you must have Administrator privilege and for

Página 393

NOTE: Export to an IPv6 NFS share is not supported.• -t - Specifies the file type to be exported. Valid values are xml and csv. These are case-insensi

Página 394 - Dependency None

where valid options are -i and –all.racadm jobqueue create <fqdd> [-r <reboot type> ] [-s <start time> ] [-e <expiry time>] In

Comentários a estes Manuais

Sem comentários