RACADM Command Line Reference Guide for iDRAC7 1.30.30 and CMC 4.3
cfgLdapEnable (Read/Write)...19
Exampleracadm krbkeytabupload -f c:\keytab\krbkeytab.tablclogDescription Allows you to export the lifecycle log history, view the lifecycle log for a
NOTE: This parameter input is an integer. If an alphanumeric input is provided, then invalid subcommand syntax error is displayed.• -n — Specifies the
NOTE: To view or export the lifecycle log you need Login to iDRAC permission only.Example• Display the number of records present in the Lifecycle Log:
• racadm license delete -c <component>• racadm license replace -t 1• racadm license replace -u <username>-p <password> -f <licens
Examples• View All License Information on System$racadm license viewiDRAC.Embedded.1 Status = OK Device = iD
• Export license to a CIFS share specifying the entitlement ID, in this case abcdxyz :racadm license export -u admin -p passwd -f License.xml-l //192.
ff00::/8 :: U 256 0 0 eth1Kernel IP routing tableDestination
• Displays the statistics for the integrated NIC.$ racadm nicstatistics NIC.Integrated.1-1Total Bytes Received:0Total Bytes Transmitted:
Reply from 2011:de11:bdc:194::31: time<1ms Reply from 2011:de11:bdc:194::31: time<1ms Ping statistics for 2011:de11:bdc:194::31: Packets: Sen
Exampleracadm racdump=============================================================================== General System/RAC Information===================
cfgChassisPowerCapBTU (Read/Write)...201cfgChassi
<senType> <Num> <sensorName> <status> <AC-OK status>PWR 1 PS-1 Online OKPWR 2
• To reset CMC:racadm racreset• To reset server 1:racadm racreset -m server-1• To reset servers 1 and 3:racadm racreset -m server-1 server-3• To force
iDRAC only options:• -f — Force resetcfg. If any VFlash partition creation or formatting is in progress when this command is issued, iDRAC sends back
• Monitor and Inventory all batteries connected to the controllerracadm raid get batteries --refkey <controller FQDDsseparated by comma>The abov
The above command displays all fan keys connected to the enclosures referred as refkeys.racadm raid get fans --refkey <enclosure FQDDs separatedby
Input• -c- Connect the image.• -d - Disconnect image.• -u - Username to access the network share.• -p- Password to access the network share.• -l - Ima
• Deploy a remote image on iDRAC NFS share for all the servers: racadm remoteimage -c -a -l '192.168.0.180:/dev/floppy.img' -u root -p calvi
• Get Power Status on iDRACracadm serveraction powerstatusServer Power Status: ON• Reseat blade 2 on CMC$ racadm serveraction -m server-2 reseat -fSer
• -s — Power state of the host when the import operation completes. The parameters are "On" for powered ON and "Off" for powered O
• —e — Enables to select existing or create new group for a member. The valid values are:– 0 — to create new group– 1 — to use existing groupNOTE: If
cfgIpmiPetAlertDestIpAddr (Read/Write)...210cfgIpmi
Legal value: chassisYou can obtain the same output if you do not include this option, as there is only one legal value.<assettag> is a maximum o
• racadm setflexaddr -f A 1 Fabric A FlexAddress state set successfully• racadm setflexaddr -f idrac 1setledDescription Sets the state (blinking or no
setniccfgDescription Sets the iDRAC IP address. It displays an error message if the requested operation could not be performed, or a success message i
— mm is the month— dd is the day— hh is the hour— mm is the minutes— ss is the seconds— mmmmmm is the number of microseconds— s is a + (plus) sign or
setslotnameDescription Displays the name and hostname (if available) of all 16 slots, or of a specified slot (indicated by the slot number) in the cha
• -c — Sets the chassis name or location.Exampleracadm setsysinfo -c chassisname "Dell Rack System"The chassis name was set successfully.ssh
options. <key index> must be between 1 to 4 or all on iDRAC.• -t <PK Key Text> - Key text for the SSH Public key.• -f <filename> - F
2 = CA certificate for Directory Service3 = Custom signing certificateOutput Returns 0 when successful and a nonzero number when unsuccessful.Exampler
• Uploading a PKCS file without any passphrase:racadm sslcertupload –t 3 –f <filename>• Uploading a PKCS file with a passphrase:racadm sslcertup
Organizational Unit (OU)Remote Access GroupCommon Name (CN) iDRAC Default certificateCommon Name (CN) iDRAC Default certificateValid From Jul 8 16:21:
cfgKVMInfo...
sslcsrgenDescription Generates and downloads a CSR file to the client’s local file system. The CSR can be used for creating a custom SSL certificate t
1 = SSL key used to generate the server certificate• -f — Specifies the file name of the SSL key to be uploaded.Output Returns 0 when successful and a
• -l — Network share location, can be either CIFS or NFS.• -f — Image file name.• -u — Username for the remote share access.• -p — Password for the re
• Enable the alert — racadm config -g cfgEmailAlert -o cfgEmailAlertEnable -i 1• Set the destination e-mail address —racadm config -g cfgEmailAlert -o
This subcommand when executed performs the following:• Checks command syntax.• Verifies whether the required system resources are available.• Validate
• Verifies that the CMC acquires a Kerberos TGT.• Acquires user privileges from the Active Directory server.• Checks the time to acquire user privileg
• View the current test trap settingsracadm getconfig -g cfgIpmiPet -i <index>where <index> is a number from 1 to 4testalertDescription Te
To use this subcommand for CMC, you must have Administrator privilege and for iDRAC, you must have Execute Diagnostic Commands permission.Synopsisraca
To use this subcommand, you must have Configure iDRAC permission.This option is applicable only to iDRAC.Synopsisracadm usercertupload -t <type>
• racadm vflashsd statusvflashpartitionDescription Manages the partitions on the vFlash SD card.NOTE: To use this subcommand, you must have the iDRAC7
cfgIPv6StaticEnable (Read or Write)...229cfg
• Status of all existing partitions:racadm vflashpartition status -a• List all the existing partitions and its properties:racadm vflashpartition listv
3iDRAC and CMC Property Database Group and Object DescriptionsThe iDRAC and CMC property database contains the configuration information for iDRAC and
Subcommand iDRAC on Blade Servers iDRAC on Rack and Tower ServersCMCifcRacManagedNodeOsYes Yes NocfgRacSecurityNo No YescfgRacVirtualYes Yes NocfgServ
idRacInfoThis group contains display parameters to provide information about the specifics of iDRAC or CMC being queried. One instance of the group is
Default for CMC CMCiDRAC Type (Read Only)Description Identifies the remote access controller type.Legal Values Product IDDefault For CMC: 9For 10G iDR
cfgNicIPv4Enable (Read or Write)Description Enables or disables iDRAC or CMC IPv4 stack.Legal Values• 1 (TRUE)• 0 (FALSE)Default 0cfgNicSelection (Rea
NOTE: For iDRAC Enterprise on Blade Servers, this object enables or disables the VLAN capabilities of iDRAC from CMC.This is Read only for iDRAC on Bl
cfgDNSDomainNameFromDHCP (Read/Write)Description Specifies that iDRAC or CMC DNS domain name should be assigned from the network DHCP server.Legal Val
Default For iDRAC: idrac-<service tag>For CMC: cmc-<service tag>cfgDNSRegisterRac (Read/Write)Description Registers the iDRAC or CMC name
cfgDNSServersFromDHCP (Read/Write)Description Specifies if the DNS server IPv4 addresses should be assigned from the DHCP server on the network.For CM
cfgSmartCard...
cfgNicIpAddress (Read/Write)Description Specifies the static IPv4 address to be assigned to the RAC or CMC.NOTE: This parameter is only configurable i
cfgNicUseDhcp (Read/Write)Description Specifies whether DHCP is used to assign the iDRAC or CMC IPv4 address. If this property is set to 1 (TRUE), the
cfgNicStaticIPv4Enable (Read or Write)Description Enables or disables the IPv4 stack.Legal Values• 0 — Disabled• 1 — EnabledDefault 1 — EnabledNOTE: I
cfgNicStaticGateway (Read or Write)Description Returns or sets the static IPv4 address.Legal Values Any Valid IPv4 addressDefault 192.168.0.120cfgDNSS
NOTE: Microsoft Active Directory only supports Fully Qualified Domain Names (FQDN) of 64 characters or fewer length.Default NullcfgDNSStaticDomainName
cfgRhostsFwUpdatePath (Read/Write)Description Specifies TFTP path where iDRAC or CMC firmware image file exists on the TFTP server. The TFTP path is r
This object is applicable only for CMC.Legal Values A string representing a valid NTP server. For example, ntp2.ntp.net. At least one NTP server must
cfgRhostsSyslogServer1 (Read/Write)Description Specifies the first of three possible remote syslog servers to store the RAC and SEL logs.This property
cfgRhostsSyslogPowerLoggingIntervalDescription Specifies the power consumption collection/logging interval.This object is applicable only for CMC.NOTE
For CMC, the index number is used to specify a unique group name. Only valid for indexed groups.Legal Values• For iDRAC: This parameter is populated b
4 Database Objects With Get and Set Commands...247System.LCD...
Clear Logs 0x00000008Execute Server Control Commands 0x00000010Access Virtual Console 0x00000020Access Virtual Media 0x00000040Test Alerts 0x00000080E
cfgUserAdminUserName (Read/Write)Description The name of the user for this index. The user index is created by writing a string into this name field i
Default 0cfgUserAdminIpmiSerialPrivilege (Read/Write)Description The maximum privilege on the IPMI LAN channel.This object is applicable only for iDRA
cfgEmailAlertAddress (Read/Write)Description Specifies the destination email address for email alerts, for example, [email protected] Values E-m
cfgSsnMgtRacadmTimeout (Read/Write)Description Defines the idle timeout in seconds for the Remote RACADM interface. If a remote RACADM session remains
After the message is displayed, the system returns to the shell that generated the Secure Shell session.Legal Values• 0 (No timeout)• 60 – 10800NOTE:
cfgSerialBaudRate (Read/Write)Description Sets the baud rate on iDRAC or CMC serial port.Legal Values• For iDRAC: 9600, 28800, 57600, 115200• For CMC:
Configuration options: The value must start with the ^ character, and be followed by one of the characters— a-z, A-Z, [, ], \Legal value: String of up
NOTE: The prompt counts as two characters.NOTE: The terminal emulator must be configured with the line wrap mode ON, if a terminal emulator is used.Le
cfgSerialTelnetEnable (Read/Write) Description Enables or disables the Telnet console interface on iDRAC or CMC.Legal Values• 1 (TRUE)• 0 (FALSE)Defau
System.Power.Max.LastWeek (Read Only)...256System.Pow
cfgTrapsThis group displays information for and configures delivery of SNMP traps for a specific user.This object property is applicable only to CMC.
cfgTrapsAlertDestIpAddr=cfgTrapsCommunityName=publiccfgRacTuningThis group is used to configure various iDRAC or CMC configuration properties, such as
cfgRacTuneHttpPort (Read/Write)Description Specifies the port number to use for HTTP network communication with iDRAC or CMC.Legal Values 10 – 65535NO
Default 192.168.1.1cfgRacTuneIpRangeMask (Read/Write)Description Standard IP mask values with left-justified bits. For example, 255.255.255.0.For CMC,
cfgRacTuneIpBlkPenaltyTime (Read/Write)Description Defines the time span in seconds that session requests from an IP address with excessive failures a
This object property is applicable only to iDRAC.Legal Values• 1 (TRUE)• 0 (FALSE)Default 1cfgRacTuneAsrEnable (Read/Write)Description Enables or disa
• –420 (MST—Mountain Standard Time)• –360 (CST—Central Standard Time)• –300 (EST—Eastern Standard Time)For CMC: This object property is read only. Spe
Default 0cfgRacTuneWebserverEnable (Read/Write)Description Enables or disables iDRAC or CMC web server. If this property is disabled, iDRAC or CMC is
• 1 = Use Java PluginDefault 0 = Active X /Native PluginifcRacManagedNodeOsThis group contains properties that describe the managed server operating s
cfgVirtualBootOnce (Read/Write)Description Enables or disables the Virtual Media Boot Once feature of iDRAC.If this property is enabled when the host
iDRAC.ActiveDirectory.Enable (Read or Write)...265iDRAC.Acti
Default 0cfgServerInfoFor iDRAC this group allows you to select the BIOS first boot device and provides the option to boot the selected device only on
cfgServerFW (Read Only)Description Displays the server's iDRAC management firmware revision.This object is applicable only to CMC.Legal Values No
cfgServerNic3MacAddress (Read Only)Description Displays the MAC address of the server NIC 3.This object is applicable only to CMC.Legal Values NoneDef
cfgServerPowerBudgetAllocation (Read Only)Description Displays the current power allocation for the server.This object is applicable only to CMC.Legal
NOTE: For a vFlash Partition to be configured as First Boot Device, it has to be attached first. When a detached / non-existent VFlash partition or a
# cfgServerBmcMacAddress=00:21:9B:FE:5F:58# cfgServerNic1MacAddress=00:0D:56:B8:69:63170 CMC Property Database Group and Object Definitions# cfgServer
The following sections provide information about the objects in the cfgActiveDirectory group.cfgADRacDomain (Read/Write)Description Active Directory D
• 0 (Disable)Default 0cfgADSSOEnable (Read/Write)Description Enables or disables Active Directory single sign-on authentication on iDRAC.Legal Values•
This object is applicable only to iDRAC.Legal Values A string of up to 254 ASCII characters representing a valid IP address or a fully qualified domai
Exampleracadm getconfig -g cfgActiveDirectorycfgADEnable=1cfgADSCLEnable=0cfgADSSOEnable=0cfgADRacDomain=cfgADRootDomain=helpcfgADRacName=cfgADRacAuth
iDRAC.IPMISerial.BaudRate (Read or Write)...274iDRAC.IPM
• 0 (FALSE)Default 1cfgADDcSRVLookupEnable (Read/Write)Description Configures iDRAC to use pre‑configured domain controllers or to use DNS to find the
cfgADGcSRVLookupEnable (Read/Write)Description Determines how the global catalog server is looked up. If using pre‑configured global catalog servers,
cfgLdapServer (Read/Write)Description Configures the address of the LDAP Server. IPv4 and IPv6 are supported.NOTE: You can specify multiple servers by
cfgLdapGroupAttribute (Read/Write)Description Specifies which LDAP attribute is used to check for group membership. This should be an attribute of the
Default NullcfgLdapSearchFilter (Read/Write)Description A valid LDAP search filter. This is used if the user attribute cannot uniquely identify the lo
This object is applicable only to CMC.Legal Values• 1 (true)• 0 (false)Default 0cfgLDAPSRVLookupDomainNameDescription Configures the domain name to be
This object is applicable only for iDRAC.Legal Values An integer between 1 and 5Default <instance>cfgLdapRoleGroupDN (Read/Write)Description Thi
Default 0cfgLocationRack (Read/Write)Description Indicates rack where server is located.Legal Values String of up to 128 ASCII charactersDefault 0cfgL
Default <blank>cfgSSADRoleGroupDomain (Read/Write)Description Active Directory Domain in which the Role Group resides.Legal Values Any printable
NOTE: You can configure any setting that is not preceded by the hash sign (#) in the output. To modify a configurable object, use the -o option.The fo
Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates
iDRAC.IPv6.Address12 (Read Only)...283iDR
cfgChassisMinPower (Read Only)Description The minimum system input power consumption value (in watts) over the time since the value was last cleared.L
cfgChassisPowerCapF (Read/Write)Description Indicates the maximum power consumption limit (in watts) for the entire chassis. Use cfgChassisPowerCapF w
cfgChassisPowerCapFPercent (Read/Write)Description Indicates the power consumption limit as a percentage. The percentage is computed mathematically as
cfgChassisMaxPowerConservationMode (Read/Write)Description Enables or disables maximum power conservation mode. When enabled, all servers are immediat
cfgChassisInPowerServerAllocation (Read Only)Description Indicates (in watts) the cumulative power allocated to servers. There is no default as this p
cfgChassisPowerButtonEnable (Read/Write)Description Indicates if the chassis power button is enabled or disabled.Legal Values• 0 (disabled)• 1 (enable
cfgIpmiSolThis group is applicable only for iDRAC and is used to configure the Serial Over LAN (SOL) capabilities of the system.The following sections
cfgIpmiSolSendThreshold (Read/Write)Description Specifies the SOL threshold limit value and the maximum number of bytes to buffer before sending an SO
cfgIpmiLanEncryptionKey (Read/Write)Description Specifies the IPMI encryption key.Legal Values A string of hexadecimal digits from 0 to 40 characters
cfgIpmiPefThis group is applicable only for iDRAC and is used to configure the platform event filters available on the managed server.The event filter
iDRAC.NIC...
cfgIpmiPetThis group is applicable only for iDRAC and is used to configure platform event traps on the managed server.The following sections provide i
cfguserdomainnameDescription Specifies the Active Directory user domain name.Legal Values A string of up to 254 ASCII charactersDefault <blank>c
cfgServerPowerCapEnable (Read/Write)Description Enables or disables the user specified power budget threshold.This object is Read only for iDRAC Enter
Default Maximum power consumption timestamp.cfgServerPowerConsumptionClear (Write Only)Description Clears the current recorded power statistics.This o
cfgServerPowerLastHourAvg (Read Only)Description Displays the average power value during the last hour.This object is applicable only for iDRAC.Legal
• HH = hour• MM=Minutes• SS = SecondsDefault Minimum power value during the last minute.cfgServerPowerLastHourMaxPower (Read Only)Description Displays
where,• DD = Day of the week• MM = Month• Date = Date• YYYY = Year• HH = hour• MM = Minutes• SS = SecondsDefault Minimum power value during the last d
cfgServerPowerLastWeekMinTime (Read Only)Description Displays the timestamp of minimum power value during the last week.This object is applicable only
cfgServerPowerInstHeadroom (Read Only)Description Displays the difference between the available power and the current power consumption.This object is
where,• DD = Day of the week• MM = Month• Date = Date• YYYY = Year• HH = hour• MM = Minutes• SS = SecondsDefault Timestamp of the current peak power c
iDRAC.Security.CsrCommonName (Read or Write)...301iDRAC.Security.C
cfgServerPowerPCIeAllocation (Read/Write)Description Amount of power allocated to the PCIe cards.This object is applicable for iDRAC Enterprise only f
Use this object with the config or getconfig subcommands.To use this object property, you must have Chassis Configuration Administrator privilege.cfgA
cfgServerPowerSupplyThis group is applicable only for iDRAC and contains information related to the power supplies. The following sections provide inf
cfgServerPowerSupplyFwVer (Read Only)Description Displays the firmware version of the power supply unit, in the format x.xx.xxx.Legal Values A string
NOTE: This object is applicable only for CMC.Legal Values A string representing a valid IPv6 address. For example, 2001:DB8:1234:5678:9ABC:DE11:C00C:B
• 0 (FALSE)Default• For iDRAC: 0• For CMC: 1cfgIPv6LinkLocalAddress (Read Only)Description The iDRAC IPv6 link local address.This object is applicable
cfgIPv6Address6 (Read Only)Description The iDRAC IPv6 sixth address.This object is applicable only for iDRAC.Legal Values String representing a valid
Default ::cfgIPv6Address12 (Read Only)Description The iDRAC IPv6 twelfth address.This object is applicable only for iDRAC.Legal Values String represen
cfgIPv6DNSServer1 (Read/Write)Description Specifies the IPv6 DNS server address.NOTE: This property is used only if cfgIPv6DNSServersFromDHCP6 is set
cfgIPv6StaticEnable (Read or Write)Description Enables or disables the static IPv6 stack.Legal Values• 0 — Disabled• 1 — EnabledDefault 0 — DisabledNO
iDRAC.Telnet.Port (Read or Write)...310i
cfgIPv6StaticDNSServersFromDHCP6 (Read or Write)Description Specifies the DNS server static IP addresses.Legal Values• 0 — DNS Server should be config
cfgNicCurrentGatewayDisplays the static gateway for the CMC IP address.Description Displays the static gateway for the CMC IP address.Legal ValuesDefa
cfgDNSCurrentServer2Description Displays the IP address for DNS server 2.Legal ValuesDefaultcfgDNSCurrentDomainNameDescription Displays the DNS domain
cfgCurrentIPv6EnabledDescription Indicates whether IPv6 is enabled on the CMC. If the current property value is set to 0 (false), the remote network i
cfgCurrentIPv6DNSServersFromDHCP6 Description Indicates whether the DNS server addresses are assigned from the DHCPv6 server.Legal ValuesDefaultcfgCur
It is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers or CMC.cfgIpmiSerialBaudRate (Read/Write)Descr
cfgIpmiSerialHandshakeControl (Read/Write)Description Enables or disables the IPMI terminal mode handshake control.Legal Values• 0 (FALSE)• 1 (TRUE)De
• 3 (<CR>)• 4 (<LF-CR>)• 5 (<LF>)Default 1cfgIpmiSerialInputNewLineSequence (Read/Write)Description Specifies the input newline sequ
cfgNetTuningThis group enables users to configure the advanced network interface parameters for the RAC NIC or CMC. When configured, the updated setti
cfgNetTuningNicFullDuplex (Read/Write)Description Specifies the duplex setting for the RAC or CMC NIC. This property is used only if the cfgNetTuningN
BIOS.BiosBootSettings...
cfgSensorRedundancyCapabilities (Read Only)Description Returns the redundancy capabilities in the form of a bitmask. This bitmask allows the user to k
cfgVFlashSDEnable (Read/Write)Description Enables or disables the vFlash SD card.NOTE: Disabling vFlashPartition by setting cfgVFlashSDEnable to 0 doe
• UnknownDefault OKcfgVFlashSDWriteProtect (Read Only)Description Displays whether the physical write-protect latch on the vFlash SD card is enabled o
cfgVFlashPartitionFlashOSVolLabelDescription Displays the label for the partition that is visible to the operating system.Legal Values An alphanumeric
The following section provide information about the objects in the cfgLogging group:cfgLoggingSELOEMEventFilterEnable (Read/Write)Description Enables
cfgRacSecCsrLocalityName (Read/Write)Description Specifies the CSR Locality (L).Legal Values A string of up to 254 characters.Default <blank>cfg
cfgRacSecCsrKeySize (Read/Write)Description Specifies the SSL asymmetric key size for the CSRs.Legal Values 512, 1024, 2048Default 1024246
4Database Objects With Get and Set CommandsThis chapter provides the database groups and objects that must be used with the get or set subcommands. Th
• 256-System Watts• 512-Asset TagWrite Privilege Configure iDRAC and Configure UserLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency None
Dependency NoneSystem.Location.DeviceSize (Read Only)Description Indicates server chassis size.Legal Values Values from 1 - 255Write Privilege Config
BIOS.MemSettings.VideoMem (Read Only)...329BIOS.MiscSe
Dependency NoneSystem.Location.Chassis.Slot (Read or Write)Description Indicates chassis slot.Legal Values Values from 1 - 255Write Privilege Configur
Write Privilege Configure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneSystem.Power.Avg.LastWeek (Read Only)Description Ind
System.Power.Cap.Btuhr (Read or Write)Description Represents the maximum power in BTU/Hr a device is allowed to consume. The device may throttle in or
License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneSystem.Power.Cap.Percent (Read or Write)Description Represents the maximum power as
License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneSystem.Power.EnergyConsumption.StarttimeStamp ( Read Only )Description Displays the
Write Privilege Configure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneSystem.Power.Max.Amps.TimeStamp (Read Only)Descript
System.Power.Max.LastHour (Read Only)Description Displays the maximum power value during the last hour.Legal Values Values from 1 - 65535Write Privile
Dependency NoneSystem.Power.Max.Power.Timestamp (Read Only)Description Displays time of maximum power consumption.Legal Values String of up to 254 ASC
Dependency NoneSystem.Power.Min.LastHour.Timestamp (Read Only)Description Indicates the timestamp of minimum power during the last hour.Legal Values
System.Power.PFCEnable (Read or Write)Description Enables the power factor correction enable.NOTE: • This object is supported only for iDRAC on Rack a
BIOS.ProcSettings.ProcBusSpeed (Read Only)...338BIOS.ProcSet
Default 0System.Power.SupplyThis group provides information relating to the Power Supplies.This group is indexed from 1 to 4. If there are less than 4
System.Power.Supply.[i].Status (Read Only)Description Displays the status of the power supply unit.Legal Values• 0 - absent• 1 - present and OK• 2 - f
System.ServerOS.OSName (Read or Write)Description Displays the operating system name of the managed server.Legal Values String of up to 254 ASCII char
LC.LCAttributes.PartConfigurationUpdate (Read or Write)Description Apply hardware configuration to the replaced part on part replacement.Legal Values
Write Privilege Configure iDRACLicense Required iDRAC7 EnterpriseDependency NoneiDRAC.ActiveDirectory.DCLookupByUserDomain (Read or Write)Description
iDRAC.ActiveDirectory.DomainController1 (Read or Write)Description FQDN that stores the address of the active directory domain controller 1.Legal Valu
Write Privilege Configure iDRACLicense Required iDRAC7 EnterpriseDependency Cannot be enabled unless one of the following is configured:• IPv4.DNS1• I
License Required iDRAC7 EnterpriseDependency NoneiDRAC.ActiveDirectory.RacDomain (Read or Write)Description Active Directory Domain in which iDRAC res
iDRAC.ADGroup.Domain (Read or Write)Description Active Directory Domain in which the Role Group resides.Legal Values String of up to 254 ASCII charact
iDRAC.EmailAlertUse the objects in this group to configure e-mail alerting capabilities.iDRAC.EmailAlert.Address (Read or Write)Description Specifies
BIOS.SataSettings.SataPortFCapacity (Read Only)...348BIOS.SataSett
Dependency NoneiDRAC.Info.Description (Read Only)Description Text description of the iDRAC.Legal Values String of up to 255 ASCII charactersWrite Priv
Write Privilege Configure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.IPBlockingUse the objects in this group to con
License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.IPBlocking.RangeAddr (Read or Write)Description Specifies the acceptable IPv4
License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.IPMILan.CommunityName (Read or Write)Description Specifies the SNMP community
iDRAC.IPMISerialUse the objects in this group to configure the IPMI serial interface.NOTE: This is supported only for rack and tower systems.iDRAC.IPM
iDRAC.IPMISerial.DeleteControl (Read or Write)Description Enables or disables delete control on the IPMI serial interface.Legal Values• 0 — Disabled•
iDRAC.IPMISerial.InputNewLineSeq (Read or Write)Description Specifies the input new line sequence for the IPMI serial interface.Legal Values• 1- Enter
iDRAC.IPMISOL.AccumulateInterval (Read or Write)Description Specifies the typical amount of time that iDRAC waits before transmitting a partial SOL ch
iDRAC.IPMISOL.SendThreshold (Read or Write)Description Specifies the SOL threshold limit value and the maximum number of bytes to buffer before sendin
iDRAC.IPv4.DNS2 (Read or Write)Description IPv4 address for DNS Server 2.Legal Values Valid IPv4 AddressWrite Privilege Configure iDRACLicense Require
BIOS.SysProfileSettings.ProcTurboMode (Read or Write)...358BIOS.SysProfileSet
iDRAC.IPv4.Netmask (Read or Write)Description The subnet mask used for the iDRAC IPv4 address.Legal Values Valid IPv4 netmaskWrite Privilege Configure
iDRAC.IPv4Static.Gateway (Read or Write)Description iDRAC static IPv4 gateway. This address can be configured even when DHCP is enabled.Legal Values V
iDRAC.IPv6.Address 5 (Read Only)Description iDRAC IPv6 fifth address.Legal Values Valid IPv6 AddressWrite Privilege Configure iDRACLicense Required iD
iDRAC.IPv6.Address1 (Read or Write)Description iDRAC IPv6 Address.Legal Values Valid IPv6 AddressWrite Privilege Configure iDRACLicense Required iDRAC
iDRAC.IPv6.Address14 (Read Only)Description iDRAC IPv6 fourteenth address.Legal Values Valid IPv6 AddressWrite Privilege Configure iDRACLicense Requir
License Required iDRAC7 Express or iDRAC7 EnterpriseDependency Cannot be set unless IPv6.DNSFromDHCP6 is disabled.iDRAC.IPv6.DNS2 (Read or Write)Descr
iDRAC.IPv6.LinkLocalAddress (Read or Write)Description iDRAC IPv6 Link Local Address.Legal Values Valid IPv6 AddressWrite Privilege Configure iDRACLic
iDRAC.IPv6Static.DNS2 (Read or Write)Description Statically configurable DNS Server 2.Legal Values Valid IPv6 AddressWrite Privilege Configure iDRACLi
iDRAC.IPv6URL.URL (Read Only)Description iDRAC IPv6 URL String of format 'https://[ipv6 address]:<port number>'Legal Values IPv6 URL S
iDRAC.LDAP.CertValidationEnable (Read or Write)Description Controls certificate validation during SSL handshake.Legal Values• 0 — Disabled• 1 — Enable
NIC.FCoEConfiguration.MTUParams (Read or Write)...369NIC.FCoEGenParam
iDRAC.LDAP.Port (Read or Write)Description Port of LDAP over SSL.Legal Values Integer values from 1- 65535Write Privilege Configure iDRACLicense Requi
iDRAC.LDAPRoleGroup.DN (Read or Write)Description This is the Domain Name of the group.Legal Values String of up to 1024 ASCII charactersWrite Privile
Dependency NoneiDRAC.LoggingiDRAC. Logging Manages the ability to configure iDRACiDRAC.Logging.SELOEMEventFilterEnable (Read or Write)Description Enab
iDRAC.NIC.DedicatedNICScanTime (Read or Write)Description Wait time for the iDRAC to switch from dedicated mode to shared mode.Legal Values Integral v
iDRAC.NIC.DNSRacName (Read or Write)Description The iDRAC name.Legal Values String of up to 63 ASCII charactersWrite Privilege Configure iDRACLicense
iDRAC.NIC.Failover (Read or Write)Description Enables or disables failover for idrac to switch from shared to dedicated.Legal Values• 0- None• 2- LOM1
Write Privilege Configure iDRACLicense Required iDRAC7 Express (for Blades) or iDRAC7 EnterpriseDependency NoneiDRAC.NIC.SharedNICScanTime (Read or Wr
NOTE: This object is applicable only to iDRAC on Racks and Towers.Legal Values Integral values from 1 - 4069Write Privilege Configure iDRACLicense Req
iDRAC.NTPConfigGroupUse the objects in this group to configure the properties of NTP server.iDRAC.NTPConfigGroup.NTP1 (Read or Write)Description Confi
iDRAC.NTPConfigGroup.NTPMaxDist (Read or Write)Description NTP Maximum DistanceLegal Values Integral values from 1 to 128Write Privilege Configure iDR
ContentsNotes, Cautions, and Warnings...21 Introductio
NIC.IscsiInitiatorParams.IscsiInitiatorPrimDns (Read or Write)...379NIC.IscsiInitiato
iDRAC.RacadmUse the objects in this group to manage Remote RACADM connection settings.iDRAC.Racadm.Enable (Read or Write)Description Enables or disabl
iDRAC.RFS.AttachMode (Read or Write)Description RFS Media attach mode.Write Privilege Configure iDRACLegal Values• 0- Attach• 1- Auto AttachLicense Re
iDRAC.Security.CsrEmailAddr (Read or Write)Description Specifies the CSR email address.Legal Values Valid email address string of up to 254 ASCII char
License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.Security.CsrStateName (Read or Write)Description Specifies the CSR State Name
iDRAC.Serial.Enable (Read or Write)Description Enables or disables the iDRAC serial console interface.Legal Values• 0 — Disabled• 1 — EnabledWrite Pri
NOTE: This is supported only for rack and tower systems.iDRAC.SerialRedirection.Enable (Read or Write)Description Enables or disables the console for
Write Privilege Configure iDRAC and Configure UserLicense Required iDRAC7 EnterpriseDependency ActiveDirectory.SSOEnable has to be disablediDRAC.SNMPT
License Required NoneDependency NoneiDRAC.SNMP.SNMPProtocol (Read or Write)Description Specified the SNMP protocol.Legal Values• 0- All• 1- SNMPv3Writ
Write Privilege Configure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.SSH.Timeout (Read or Write)Description Defines
Dependency NoneiDRAC.SysLog.Server1 (Read or Write)Description Name of remote syslog server 1.Legal Values String of up to 63 ACSII charactersWrite Pr
NIC.VndrConfigGroup.iSCSIOffloadSupport (Read Only)...388NIC.VndrConfigGro
iDRAC.Telnet.Enable (Read or Write)Description Enables or disables Telnet.Legal Values• 0 — Disabled• 1 — EnabledWrite Privilege Configure iDRACLicens
iDRAC.TuningThe objects in this group enable you to manage iDRAC tuning and configuration parameters.iDRAC.Tuning.DefaultCredentialWarning (Read or Wr
• 1- EnabledWrite Privilege Configure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.UserDomainThe objects in this grou
License Required iDRAC7 Express or iDRAC7 EnterpriseDependency Both user name and password must be configured prior to setting this object.iDRAC.Users
Write Privilege Configure iDRAC and Configure UserLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneiDRAC.Users.SNMPv3Enable (Read or
Dependency NoneiDRAC.VirtualConsoleThe objects in this group enable you to manage virtual console configuration parameters of iDRAC.iDRAC.VirtualConso
• 1 — EnabledWrite Privilege Configure iDRACLicense Required iDRAC7 Express (For Blades) or iDRAC7 EnterpriseDependency NoneiDRAC.VirtualConsole.MaxSe
iDRAC.VirtualMediaThe objects in this group enable you to manage virtual media configuration parameters of iDRAC.iDRAC.VirtualMedia.Attached (Read or
iDRAC.WebServer.Enable (Read or Write)Description Enables or disables iDRAC WebServer.Legal Values• 0 — Disabled• 1 — EnabledWrite Privilege Configure
Write Privilege Configure iDRACLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.BiosBootSettingsYou can manage the BIOS boot se
Dependency Read Only if BootMode is set to UEFIBIOS.BiosBootSettings.UefiBootSeq (Read or Write)Description UEFI boot sequenceLegal Values NoneWrite P
BIOS.IntegratedDevices.EmbNic2 (Read or Write)Description Enables or disables the operating system interface of the embedded NIC2.Legal Values• Enable
BIOS.IntegratedDevices.EmbNic4 (Read or Write)Description Enables or disables the operating system interface of the embedded NIC4.Legal Values• Enable
License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.IntegratedDevices.IntegratedRaid (Read or Write)Description Enables or disable
Dependency Read Only if 'InternalSdCard' is set to 'Off'.BIOS.IntegratedDevices.InternalUsb (Read or Write)Description Enable or d
BIOS.IntegratedDevices.SriovGlobalEnable (Read or Write)Description Enables or disables BIOS configuration of Single Root I/O Virtualization (SR-IOV)
• MirrorMode• AdvEccMode• SpareWithAdvEccModeWrite Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.Mem
BIOS.MemSettings.MemVolt (Read or Write)Description Sets the DIMM voltage selection.Legal Values• AutoVolt• Volt135V• Volt15VWrite Privilege Server Co
• ValidWrite Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.MemSettings.RedundantMemInUse (Read Only)
Dependency NoneBIOS.MemSettings.SysMemType (Read Only)Description Indicates the current type of main memory installed in the system.Legal Values NoneW
1IntroductionThis document provides information about the RACADM subcommands, supported RACADM interfaces, and property database groups and object def
BIOS.MiscSettings.ErrPrompt (Read or Write)Description Enables or disables the F1 and F2 prompt on error.Legal Values• Enabled• DisabledWrite Privileg
Dependency NoneBIOS.OneTimeBootYou can manage the one time boot settings using the objects in this group.BIOS.OneTimeBoot.OneTimeBootMode (Read or Wri
Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency Read Only if OneTimeBootModeis not set to OneTimeHddSeqBI
• DisabledWrite Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.ProcSettings.DcuStreamerPrefetcher (Re
BIOS.ProcSettings.Proc1Brand (Read Only)Description Provides the processor brand name.Legal Values NoneWrite Privilege Server ControlLicense Required
Dependency NoneBIOS.ProcSettings.Proc2Brand (Read Only)Description Provides the processor brand name.Legal Values NoneWrite Privilege Server ControlLi
Dependency NoneBIOS.ProcSettings.Proc3Brand (Read Only)Description Brand text provided by the processor manufacturer.Legal Values NoneWrite Privilege
Dependency NoneBIOS.ProcSettings.Proc4Brand (Read Only)Description Brand text provided by the processor manufacturer.Legal Values NoneWrite Privilege
Dependency NoneBIOS.ProcSettings.Proc64bit (Read Only)Description Specifies whether the installed processor(s) support 64-bit extensions.Legal Values
• 12• 14• 16Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.ProcSettings.ProcCoreSpeed (Read Onl
Supported RACADM InterfacesThe RACADM command-line utility provides a scriptable interface that allows you to locally or remotely configure your Remot
BIOS.ProcSettings.ProcHpcMode (Read or Write)Description Configure processor's HPC mode.Legal Values• Enabled• DisabledWrite Privilege Server Con
Dependency NoneBIOS.ProcSettings.ProcSoftwarePrefetcher (Read or Write)Description Enables or disables the hardware prefetcher for considering softwar
Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.ProcSettings.RtidSetting (Read or Write)Descript
BIOS.SataSettings.eSataPort1Capacity (Read Only)Description Displays the total capacity of a hard-disk drive.Legal Values NoneWrite Privilege Server C
License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SataSettings.SataPortADriveType (Read Only)Description Indicates type of devic
BIOS.SataSettings.SataPortBDriveType (Read Only)Description Indicates type of device attached to this SATA port.Legal Values NoneWrite Privilege Serve
License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SataSettings.SataPortCModel (Read Only)Description Displays the drive model of
BIOS.SataSettings.SataPortDDriveType (Read Only)Description Indicates type of device attached to this SATA port.Legal Values NoneWrite Privilege Serve
License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SataSettings.SataPortEModel (Read Only)Description Displays the drive model of
BIOS.SataSettings.SataPortFModel (Read Only)Description Displays the drive model of the selected device.Legal Values NoneWrite Privilege Server Contro
Remote RACADMracadm -r <racIpAddr> -u <username> -p <password> getconfig -g <groupname> [-o<objectname>] [-i <indexnu
License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SataSettings.SataPortH (Read or Write)Description Sets the drive type of the s
BIOS.SerialCommSettings.ConTermType (Read or Write)Description Configures the remote console's terminal type.Legal Values• Vt100Vt220• AnsiWrite
Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SerialCommSettings.SerialComm (Read or Write)Des
Dependency NoneBIOS.SlotDisablement.Slot2 (Read or Write)Description Control the configuration of the card installed in slot 2.Legal Values• Enabled•
Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SlotDisablement.Slot6 (Read or Write)Description
BIOS.SysInformation.SystemBiosVersion (Read Only)Description Provides the current revision of the system BIOS firmware.Legal Values NoneWrite Privileg
Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SysProfileSettingsUse the objects in this group
• DisabledWrite Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SysProfileSettings.MemRefreshRate (Rea
BIOS.SysProfileSettings.ProcCStates (Read or Write)Description Enables or disables the processor C-States.Legal Values• Enabled• DisabledWrite Privile
BIOS.SysProfileSettings.SysProfile (Read or Write)Description Sets the System Profile to Performance Per Watt (DAPC), Performance Per Watt (OS) Perfor
Supported RACADM SubcommandsThe following table provides the list of RACADM subcommands and their corresponding interface support. For detailed inform
Dependency NoneBIOS.SysSecurity.AcPwrRcvryUserDelay (Read Only)Description Controls the user defined AC Recovery Delay.Legal Values NoneWrite Privileg
• UnlockedWrite Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SysSecurity.PwrButton (Read or Write)D
• Up to 32 characters including whitespace.• Contain numbers 0 through 9.• Only lower case alphabets are accepted.• Special characters accepted are +,
• OnWrite Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneBIOS.SysSecurity.TpmActivation (Read or Write)Des
NIC.DCBSettingsThe following section provides information about the objects in the NIC.DCBSettings group.NIC.DCBSettings.CongestionNotification (Read
• UnavailableWrite Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneNIC.DeviceLevelConfigUse the objects in
Dependency NoneNIC.FCOECapabilitiesThe following section provides information about the objects in the NIC.FCOECapabilities group.NIC.FCOECapabilities
NIC.FCOECapabilities.MaxNumberExchanges (Read Only)Description Indicates the maximum number of exchanges supported.Legal Values NoneWrite Privilege Se
• UnavailableWrite Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneNIC.FCoEConfigurationThe following secti
NIC.FCoEConfiguration.FirstFCoEWWPNTarget (Read or Write)Description World Wide Port Name (WWPN) of the first FCoE storage target.Legal Values NoneWri
Subcommand iDRAC on Blade ServersiDRAC on Rack and Tower ServersCMCgetioinfo No No No No No No Yes Yesgetkvminfo No No No No No No Yes Yesgetled Yes Y
NIC.FCoEGenParams.FCoEFabricDiscoveryRetryCnt (Read or Write)Description Retry count for FCoE fabric discovery.Legal Values Values from 0 - 60Write Pr
NIC.FCoEGenParams.FCoETgtBoot (Read or Write)Description Enables the FCoE initiator to boot system to the FCoE target.Legal Values• Enabled• DisabledW
NIC.GlobalBandwidthAllocationThe following section provides information about the objects in the NIC.GlobalBandwidthAllocation group.NIC.GlobalBandwid
Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency Not Available if 'VndrConfigGroup.iSCSIBootSupport&a
License Required iDRAC7 Express or iDRAC7 EnterpriseDependency Not Available if 'VndrConfigGroup.iSCSIBootSupport' is Unavailable.NIC.IscsiF
NIC.IscsiGenParams.DhcpVendId (Read or Write)Description Control what Vendor ID is presented to the DHCP service.Legal Values String of upto 255 ASCII
License Required iDRAC7 Express or iDRAC7 EnterpriseDependency Not Available if 'VndrConfigGroup.iSCSIBootSupport' is Unavailable.NIC.IscsiG
Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency Not Available if 'IscsiGenParams.IpVer' is set
NIC.IscsiInitiatorParams.IscsiInitiatorChapPwd (Password)Description Set the iSCSI initiator Challenge-Handshake Authentication Protocol (CHAP) secret
NIC.IscsiInitiatorParams.IscsiInitiatorPrimDns (Read or Write)Description Specifies the Primary DNS IP address of the iSCSI initiator.Legal Values Str
Subcommand iDRAC on Blade ServersiDRAC on Rack and Tower ServersCMCracreset Yes Yes Yes Yes Yes Yes Yes Yesracresetcfg Yes Yes Yes Yes Yes Yes Yes Yes
NIC.IscsiSecondaryDeviceParams.SecondaryDeviceMacAddr (Read or Write)Description Specifies the MAC address of a secondary iSCSI boot adapter for redun
• DisabledWrite Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency Not available if 'VndrConfigGroup.iSCSIBoo
Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency Not available if 'VndrConfigGroup.iSCSIBootSupport&a
NIC.NICConfig.LnkSpeed (Read or Write)Description Specifies the port speed used for the selected boot protocol.Legal Values• AutoNeg• 10Mbps Half• 10M
License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneNIC.NICConfig.WakeOnLanLnkSpeed (Read or Write)Description Select the port speed us
NIC.NICPartitioningConfig.NumberPCIEFunctionsSupported (Read Only)Description Indicates the number of physical PCIe functions supported on this port.L
License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneNIC.VndrConfigGroup.DeviceName (Read Only)Description Indicates the official produc
NIC.VndrConfigGroup.FCoEOffloadSupport (Read Only)Description Indicates whether FCoE Offload capability is supported.Legal Values NoneWrite Privilege
License Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneNIC.VndrConfigGroup.ISCSIMacAddr (Read Only)Description Indicates the permanent MAC
NIC.VndrConfigGroup.MacAddr (Read Only)Description Indicates the permanent MAC address assigned during manufacturing.Legal Values String of up to 17 c
Subcommand iDRAC on Blade ServersiDRAC on Rack and Tower ServersCMCusercertviewYes Yes Yes Yes Yes Yes No NovflashsdYes Yes Yes Yes Yes Yes No Novflas
Write Privilege Server ControlLicense Required iDRAC7 Express or iDRAC7 EnterpriseDependency NoneNIC.VndrConfigGroup.OSBMCManagementPassThrough (Read
NIC.VndrConfigGroup.RXFlowControl (Read Only)Description Indicates whether Receive (RX) Flow control capability is supported.Legal Values NoneWrite Pr
NIC.VndrConfigGroup.TXFlowControl (Read Only)Description Indicates whether Transmit (TX) Flow Control capability is supported.Legal Values NoneWrite P
NIC.VndrConfigGroup.VirtualLinkControl (Read or Write)Description Indicates whether Virtual Link Control capability is supported.Legal Values NoneWrit
License Required iDRAC7 Express or iDRAC7 EnterpriseDependency None394
getassettag...
40
2RACADM Subcommand DetailsThis section provides detailed descriptions of the RACADM subcommands including the syntax and valid entries.Guidelines to Q
NOTE: An empty string may be specified as either "" (using double quotes) or '' (using single quotes)."?"and "?<
-c : show chassis information-A : do not show headers or labels-4 : show CMC IPv4 information-6 : show CMC IPv6 informationhelp and help <subcomman
IP Address HW Type Flags HW Address Mask Device192.168.1.1 0x1 0x2 00:00:0C:07:AC:0F * eth0autocompleteDescriptionDisplays all the available racadm co
Inputracadm> cd <object>Output Use the command to execute object related get or setcommands.Example• Example 1: To execute all system related
To use this subcommand, you must have Chassis Control Administrator privilegeSynopsisracadm chassisaction [-m <module>] <action>Input• -m
closessnDescription Closes a communication session on the device. Use getssninfo to view a list of sessions that can be closed using this command.To u
To use this subcommand, you must have Administrator privilege.NOTE: This command is valid only in redundant CMC environments. For more information, se
• -c — The -c, or check option, is used with the config subcommand and allows the user to parse the .cfg file to locate syntax errors. If errors are f
set...
Input -b — Connects to the switch or console using the binary mode. This is an optional argument; a server or a switch must be present.NOTE: If you us
This option is applicable only for iDRAC.To use this subcommand, you must have Clear Logs or Execute Debug Commands permission.NOTE: If a coredumpdele
• -u root — Indicates that the <password> is supplied for the root user on the server or switch. Root is a constant parameter, the only value th
To use this subcommand with the get and test option, you must have Administrator privilege.This subcommand is applicable only for iDRAC.Synopsisracadm
• -r — Event generation interval. This is applicable only to the temperature statistics subcategory - tmps. You can use this option as a stand-alone o
featureDescription Displays all active chassis features. The information displayed includes feature name, date activated, and the serial number of the
Output• No feature card inserted — Action: Check the CMC to verify that the SD card was properly inserted. In a redundant CMC configuration, make sure
at any time. In addition, the fwupdate subcommand may only update one or more devices of a single kind at a time.To use this subcommand for CMC you mu
Input• -u — For iDRAC: The update option performs a checksum of the firmware update file and starts the actual update process. This option may be used
NOTE: iDRAC7 targets are not supported from CMC. Use the CMC GUI to update iDRAC7 targets from CMC.CMC version 3.00 accepts IPv4, IPv6, or fully quali
cfgNicIPv4Enable (Read or Write)...145cf
NOTE: For CMC, these commands specifically apply to an active-CMC update.The following table describes the firmware update method supported for each i
• <object> — Specifies the object name of the value to be read.• <index> — Specifies where FQDD Alias's or Groups need to be indexed.
<module> configuration completed successfully.Example• Get the configured storage array properties from server-3racadm getarraycfg -m server-3•
Input• -f — The -f <filename> option directs getconfig to write the entire iDRAC configuration to a configuration file. This file can be used fo
racadm getconfig -u root• Displays the user group instance at index 2 with verbose information for the property values.racadm getconfig -g cfgUserAdmi
<Server#> <Presence> <DC1 Type> <DC1 State> <DC2 Type> <DC2 State>server-4 Present None N/A Gigabit EthernetOKserv
server-13 Not Present None Noneserver-14 Not Present None Noneserver-15 Not Present None Noneserver-16 Not Present None NonegetflexaddrDescription Di
9 Enabled Not Present10 Enabled Extension(2)11 Enabled Not Present12 Enabled Not Present13 Enabled Extension(5)14 Enabled Not Present15 Enabled Not Pr
getfanreqinfoDescription Displays fan speed request for Servers and Switches in percent (%).To use this subcommand, you must have CMC Login User privi
14 SLOT-14 PowerEdgeM600ON Present 3315 SLOT-15 N/A N/A Not Present N/A16 SLOT-16 N/A Extension(8) N/A N/ASwitch Module Fan Request Table<Slot#>
cfgRhostsSyslogServer1 (Read/Write)...157cfgRh
<IO Name> <Name> <Type> <Presence> <Fan Request%>Switch-1 Dell Ethernet Pass-ThroughGigabit EthernetPresent 30Switch-
getkvminfoDescription Displays iKVM module information.To use this subcommand, you must have CMC Login User privilege.Synopsisracadm getkvminfoExample
getmacaddressDescription Displays the MAC/WWN addresses for all modules or for a specified module.To use this subcommand, you must have CMC Login User
00:11:43:FD:B7:2C00:11:43:FD:B7:2Dracadm getmacaddress<Name> <Presence> <BMC MAC Address><NIC1 MAC Address><NIC2 MAC Addres
Switch-3 Present N/A 00:00:00:00:00:00N/ASwitch-4 Present N/A 00:00:00:00:00:00N/ASwitch-5 Present N/A 00:05:1E:08:EB:0BN/ASwitch-6 Not Present N/A N/
Server-4-B Gigabit EthernetNot Present Not InstalledNot InstallediSCSI Present Not InstalledNot InstalledServer-4-C Fibre Channel 4Present Not Install
Server-13-A Gigabit EthernetPresent 00:18:8B:FF:45:2600:18:8B:FF:A9:F200:18:8B:FF:A9:F4iSCSI Present 00:18:8B:FF:A9:F300:18:8B:FF:A9:F5Server-13-B Gig
Switch-6 N/A Not Present N/A N/A N/AgetmodinfoDescription Displays configuration and status information for all modules or a specified module (server,
Switch-2 Not Present N/A N/A N/ASwitch-3 Not Present N/A N/A N/ASwitch-4 Not Present
IPv4 settings:NIC Enabled = 1IPv4 Enabled = 1DHCP Enabled = 1IP Address = 10.35.0.64Subnet Mask = 255.255.255.0Gateway = 10.35
cfgTrapsIndex (Read Only)...
getpbinfoDescription Displays power budget status information.To use this subcommand, you must have CMC Login User privilege.Synopsisracadm getpbinfoE
9 SLOT-09 N/A N/A 5 N/A 10 SLOT-10 Extension(2) N/A 5 N/A 11 SLOT-11 N/A
Performance = 7000 W (6130 BTU/hr)Redundancy Policy = NoneDynamic PSU Engagement Enabled = No[Power Budgeting]
Message Arg 2 = 10.92.68.245FQDD = iDRAC.Embedded.1 Example• Display the starting record and the number of records.racadm getraclog -s 10 -c 2• Displ
getredundancymodeDescription Displays the redundancy status (Redundant or Non-Redundant) of the CMC.To use this subcommand, you must have CMC Login Us
For CMC:racadm getsensorinfo<senType> <Num> <sensorName> <status> <reading><units> <lc> <uc>FanSpeed
System Board Fan6B RPM Ok 5160 RPM 720 RPM NA System Board Fan7B RPM Ok 3840 RPM 720 RP
System Board CMOS Battery Ok Present NA NA Sensor Type : PERFOMANCE<Sensor Name> <Stat
11 SLOT-11 12 SLOT-12 13 SLOT-13 14 SLOT-14 15 SLOT-15 16 SLOT-16racadm getslotname -i 1Webserver-1getssnin
Exampleracadm getsvctaggetsysinfoDescription Displays information related to iDRAC, managed system, and watchdog configuration.NOTE: The local racadm
cfgServerFW (Read Only)...
Current IP Gateway = :: Autoconfig = 1Link Local IP Address = fe80::224:e8ff:fe2e:c5d3/255Current IP Address 2 = ::Current IP A
System Revision = I System BIOS Version = 0.2.3 BMC Firmware Version = 0.17 Service Tag = 48192 Host Name
Input• (none) - Displays the version information for all targets or devices.• -m <module> - Specifies the module or device for which you want to
server-2 PowerEdgeM805server-5 1.0.0 PowerEdgeM710racadm getversion -b<Server> <BIOS Version> <Blade Type>server-1 2.0.0 PowerEdgeM6
hwinventoryDescription Allows you to display or export current internal hardware inventory or shipped hardware inventory by device.To use this subcomm
Sync Time: 0x0000Product Name: QLogic CNA Gigabit Ethernet-B8:AC:6F:B3:BF:1Permanent MAC Address:
Hard Zone Address: 0Hard Zone Enable: DisabledFC Tape Enable: Dis
ifconfigDescription Displays the contents of the network interface table.To use this subcommand for CMC, you must have Administrator privilege and for
NOTE: Export to an IPv6 NFS share is not supported.• -t - Specifies the file type to be exported. Valid values are xml and csv. These are case-insensi
where valid options are -i and –all.racadm jobqueue create <fqdd> [-r <reboot type> ] [-s <start time> ] [-e <expiry time>] In
Comentários a estes Manuais