Dell OpenManage Server Administrator Version 7.3 Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Placas-mãe Dell OpenManage Server Administrator Version 7.3. Dell OpenManage Server Administrator Version 7.3 SNMP Reference Guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 567
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Dell OpenManage
SNMP Reference Guide Version 7.3
Vista de página 0
1 2 3 4 5 6 ... 566 567

Resumo do Conteúdo

Página 1 - Dell OpenManage

Dell OpenManageSNMP Reference Guide Version 7.3

Página 3 - Contents

Table 261. System Resource Interrupt TriggerName systemResourceInterruptTriggerObject ID 1.3.6.1.4.1.674.10892.1.500.50.1.10Description Defines the

Página 4

Access Read-onlyTable 266. System Resource DMA State CapabilitiesName systemResourceDMAStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.500.60.1.3

Página 5

Table 271. System Resource DMA Maximum Transfer SizeName systemResourceDMAMaximumTransferSizeObject ID 1.3.6.1.4.1.674.10892.1.500.60.1.8Description

Página 6

typeIsUnknown(2) The interface type is unknown.typeIsInternal(3) The interface type is internal.typeIsISA(4)The interface type is an Industry Standard

Página 7

interruptIsLatched(2) The interrupt type is latched.Table 279. Resource Interrupt TriggerVariable Name: DellResourceInterruptTrigger Data Type: Intege

Página 8

8Power GroupThe Power Group provides information about power units (a group of power supplies in a system chassis), power supplies, and voltage and am

Página 9

Index powerUnitchassisIndex, powerUnitIndexTable 284. Power Unit Chassis IndexName powerUnitchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.600.10.1.1

Página 10

Table 289. Power Supply Count for RedundancyName powerSupplyCountForRedundancyObject ID 1.3.6.1.4.1.674.10892.1.600.10.1.6Description Defines the to

Página 11 - Introduction

Table 294. Power Supply Chassis IndexName powerSupplychassisIndexObject ID 1.3.6.1.4.1.674.10892.1.600.12.1.1Description Defines the index (one-base

Página 12 - Supported SNMP Versions

Description Defines the maximum sustained output wattage of the power supply in tenths of watts.Syntax DellSigned32BitRangeAccess Read-onlyTable 30

Página 13

1IntroductionThis reference guide provides information about the Simple Network Management Protocol (SNMP) Management Information Base (MIB) which is

Página 14 - MIB group number

Access Read-onlyTable 305. Power Supply Configuration Error TypeName powerSupplyConfigurationErrorTypeObject ID 1.3.6.1.4.1.674.10892.1.600.12.1.12D

Página 15

Index voltageProbechassisIndex, voltageProbeIndexTable 310. Voltage Probe Chassis IndexName voltageProbechassisIndexObject ID 1.3.6.1.4.1.674.10892.

Página 16 - Basic Terminology

Table 315. Voltage Probe ReadingName voltageProbeReadingObject ID 1.3.6.1.4.1.674.10892.1.600.20.1.6Description Defines the value of the voltage pro

Página 17 - SNMP Tables

Table 320. Voltage Probe Upper Noncritical ThresholdName voltageProbeUpperNonCriticalThresholdObject ID 1.3.6.1.4.1.674.10892.1.600.20.1.11Descriptio

Página 18 - Section Organization

Description Defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete.When the value for voltageProbeType is other than voltageProbe

Página 19 - Other Documents You May Need

Access Read-onlyTable 330. Amperage Probe State CapabilitiesName amperageProbeStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.600.30.1.3Descripti

Página 20 - Table 14. ROOT

Access Read-onlyTable 334. Amperage Probe TypeName amperageProbeTypeObject ID 1.3.6.1.4.1.674.10892.1.600.30.1.7Description Defines the type of the

Página 21 - SNMP Traps

Table 339. Amperage Probe Lower Noncritical ThresholdName amperageProbeLowerNonCriticalThresholdObject ID 1.3.6.1.4.1.674.10892.1.600.30.1.12Descript

Página 22

AC Power Switch TableTable 344. AC Power Switch TableName aCPowerSwitchTableObject ID 1.3.6.1.4.1.674.10892.1.600.40Description Defines the AC Power

Página 23

Syntax DellACPowerSwitchCapabilitiesAccess Read-onlyTable 349. AC Power Switch SettingsName aCPowerSwitchSettingsObject ID 1.3.6.1.4.1.674.10892.1.

Página 24 - Access Read-only

Supported SNMP VersionsOperating System Supported OMSA SNMP versionWindows SNMP v1Linux SNMP v1Introduction to the SNMP Reference GuideThis referenc

Página 25 - Systems Management Software

Table 354. AC Power Switch StatusName aCPowerSwitchStatusObject ID 1.3.6.1.4.1.674.10892.1.600.40.1.9Description Defines the status of this AC power

Página 26

Access Read-onlyTable 359. AC Power Cord State CapabilitiesName aCPowerCordStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.600.42.1.3Description

Página 27

Battery TableTable 364. Battery TableName batteryTableObject ID 1.3.6.1.4.1.674.10892.1.600.50Description Defines the Battery Table.Syntax SEQUENCE

Página 28

Table 369. Battery State SettingsName batteryStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.600.50.1.4Description Defines the state settings of the

Página 29 - System State Group

Table 374. Power Usage Table EntryName powerUsageTableEntryObject ID 1.3.6.1.4.1.674.10892.1.600.60.1Description Defines the Power Usage Table Entry

Página 30 - System State Table

Table 379. Power Usage StatusName powerUsageStatusObject ID 1.3.6.1.4.1.674.10892.1.600.60.1.5Description Defines the status of the power usage info

Página 31

Table 384. Power Usage Peak Watts Start Date NameName powerUsagePeakWattsStartDateNameObject ID 1.3.6.1.4.1.674.10892.1.600.60.1.10Description Defin

Página 32

Table 389. Power Usage Idle PowerName powerUsageIdlePowerObject ID 1.3.6.1.4.1.674.10892.1.600.60.1.15Description Defines the system idle power (in

Página 33

Table 394. Power Usage Instantaneous HeadroomName powerUsageInstantaneousHeadroomObject ID 1.3.6.1.4.1.674.10892.1.600.60.1.20Description Defines th

Página 34

Access Read-onlyTable 399. Power Profile IndexName powerProfileIndexObject ID 1.3.6.1.4.1.674.10892.1.600.70.1.2Description Defines the index (one-

Página 35

Section Topics MIB Group Numbers6 Operating System Group — defines variables for name, version, service pack, and other information about a system’s

Página 36

Table 404. Power Profile Custom Memory Management CapabilitiesName powerProfileCustomMemoryManagementCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.60

Página 37

unknown(1) The power supply’s capabilities are unknown.onlineCapable(2) The power supply can be disabled (offline, a binary 0 value) or enabled (onlin

Página 38

powerSupplyTypeIsLinear(3) The power supply type is a linear power supply.powerSupplyTypeIsSwitching(4) The power supply type is a switching power sup

Página 39

Table 413. Voltage Probe TypeVariable Name: DellVoltageType Data Type: Integer Possible Data Values Meaning of Data Value voltageProbeTypeIsOther(1)

Página 40

amperageProbeTypeIsOther(1) The amperage probe type is not one of the following:amperageProbeTypeIsUnknown(2) The amperage probe type is unknown (not

Página 41

Table 417. AC Power Switch CapabilitiesVariable Name: DellACPowerSwitchCapabilities Data Type: IntegerPossible Data Values Meaning of Data Value unkn

Página 42

onlineCapable(2) The AC power cord can be disabled (offline) or enabled (online).notReadyCapable(4)The AC power cord’s capabilities are not ready.Tabl

Página 43

Table 424. Power Cap SettingVariable Name: DellPowerCapSetting Data Type: IntegerPossible Data Values Meaning of Data Value disabled(0) Power cap is

Página 44

NOTE: These values are bit masks, so combination values are possible.Possible Data Values Meaning of Data Value maxPerformance(1) Memory power and pe

Página 45 - Chassis Information Group

9Thermal GroupThe Thermal Group provides information about cooling units, cooling devices, and temperature probes. Cooling units are sets of fans or o

Página 46 - Chassis Status

The Server Administrator Remote Access MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. Ta

Página 47 - Chassis Model Name

Syntax TableEntryAccess Read-onlyTable 432. Cooling Unit IndexName coolingUnitIndexObject ID 1.3.6.1.4.1.674.10892.1.700.10.1.2Description Defines

Página 48 - Chassis System Class

Table 437. Cooling Unit NameName coolingUnitNameObject ID 1.3.6.1.4.1.674.10892.1.700.10.1.7Description Defines the cooling unit name in this chassi

Página 49 - Chassis System Location Name

Access Read-onlyTable 442. Cooling Device IndexName coolingDeviceIndexObject ID 1.3.6.1.4.1.674.10892.1.700.12.1.2Description Defines the index of

Página 50

Access Read-onlyTable 447. Cooling Device TypeName coolingDeviceTypeObject ID 1.3.6.1.4.1.674.10892.1.700.12.1.7Description Defines the cooling dev

Página 51

Table 452. Cooling Device Lower Noncritical ThresholdName coolingDeviceLowerNonCriticalThresholdObject ID 1.3.6.1.4.1.674.10892.1.700.12.1.12Descript

Página 52 - Chassis Lock Present

Description Defines the probe capabilities of the cooling device.Syntax DellProbeCapabilitiesAccess Read-onlyTable 458. Cooling Device Discrete Rea

Página 53

Access Read-onlyTable 462. Temperature Probe IndexName temperatureProbeIndexObject ID 1.3.6.1.4.1.674.10892.1.700.20.1.2Description Defines the ind

Página 54 - Chassis Reseller System ID

Access Read-onlyTable 467. Temperature Probe TypeName temperatureProbeTypeObject ID 1.3.6.1.4.1.674.10892.1.700.20.1.7Description Defines the tempe

Página 55 - Chassis System Revision Name

Table 472. Temperature Probe Lower Noncritical ThresholdName temperatureProbeLowerNonCriticalThresholdObject ID 1.3.6.1.4.1.674.10892.1.700.20.1.12De

Página 56 - UUID Table

Thermal Group Variable ValuesThis section includes definitions for server administrator-specific variable values used in this section.Table 477. Cooli

Página 57 - POST Log Table

Table 4. Server Administrator Storage Management MIB Sections in This GuideSection Topics MIB Group Numbers23 Storage Management Group — consists of

Página 58 - Table 104. POST Log Record

Table 479. Cooling Device Discrete ReadingVariable Name: DellCoolingDeviceDiscreteReading .Data Type: Integer Possible Data Values Meaning of Data Va

Página 59 - Event Log Table

10User Security GroupThe User Security Table defines the objects that allow administrators to create and modify user accounts and to control which use

Página 60 - Table 113. Event Log Format

Table 485. User Security IndexName userSecurityIndexObject ID 1.3.6.1.4.1.674.10892.1.800.1.2Description Defines the user security index.Syntax Del

Página 61 - System BIOS Table

11Remote Flash BIOS GroupThe Remote Flash Basic Input/Output System (BIOS) Table defines the variables used to remotely update the BIOS in a system. T

Página 62 - Table 123. System BIOS Size

Table 492. Remote Flash BIOS IndexName remoteFlashBIOSIndexObject ID 1.3.6.1.4.1.674.10892.1.900.10.1.2Description Defines the index to the remote B

Página 63

Table 497. Remote Flash BIOS Completion CodeName remoteFlashBIOSCompletionCodeObject ID 1.3.6.1.4.1.674.10892.1.900.10.1.7Description Defines the co

Página 64

canceled(8) The remote flash BIOS has been canceled.pending(16) The remote flash BIOS update is pending.other(32) The remote flash BIOS state/setting

Página 65

12Port GroupThe Port Group provides information about the different types of ports that may be present in your system. This management information bas

Página 66 - Firmware Table

,pointingPortIndexTable 504. Pointing Port Chassis IndexNamepointingPortchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1000.10.1.1Description Defines t

Página 67 - Table 138. Firmware Status

Access Read-onlyTable 509. Pointing Port Security StateNamepointingPortSecurityStateObject ID 1.3.6.1.4.1.674.10892.1.1000.10.6Description Defines the

Página 68 - Table 143. Firmware Date Name

Section Topics MIB Group Number• CMC Power Information• CMC PSU Information• Chassis Alerts• Legacy AlertingHow This Guide Defines Technical TermsThe

Página 69 - Intrusion Table

Syntax IntegerKeyboardPortTableEntryAccess Not accessibleTable 514. Keyboard Port Table EntryName keyboardPortTableEntryObject ID 1.3.6.1.4.1.674.1089

Página 70

Table 518. Keyboard Port State SettingsName keyboardPortStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.1000.20.1.4Description Defines the state and se

Página 71 - Baseboard Table

Table 523. Keyboard Port BIOS Connector TypeName keyboardPortBIOSConnectorTypeObject ID 1.3.6.1.4.1.674.10892.1.1000.20.1.9Description Defines the BIO

Página 72

Description Defines the index of the processor ports in this chassis.Syntax DellObjectRangeAccess Read-onlyTable 528. Processor Port State Capabilitie

Página 73

Syntax DellProcessorPortConnectorType (See Processor Port Connector Types)Access Read-onlyTable 533. Processor Port NameNameprocessorPortNameObject ID

Página 74 - Table 173. Log Format

Table 537. Memory Device Port Chassis IndexNamememoryDevicePortchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1000.40.1.1Description Defines the index

Página 75 - Table 175. Connection Status

Table 542. Memory Device Port Security StateNamememoryDevicePortSecurityStateObject ID 1.3.6.1.4.1.674.10892.1.1000.40.1.6Description Defines the secu

Página 76

Table 547. Memory Device Port Physical Memory Card Index ReferenceNamememoryDevicePortPhysicalMemoryCardIndexReferenceObject ID 1.3.6.1.4.1.674.10892.

Página 77

Table 551. Monitor Port IndexName monitorPortIndexObject ID 1.3.6.1.4.1.674.10892.1.1000.50.1.2Description Defines the index of the monitor ports in t

Página 78

Table 556. Monitor Port Connector TypeName monitorPortConnectorTypeObject ID 1.3.6.1.4.1.674.10892.1.1000.50.1.7Description Defines the connector type

Página 79

TablesThis reference guide contains two types of tables: tables that are used to organize and define variable values and tables that define MIB object

Página 80

IndexsCSIPortchassisIndex,sCSIPortIndexTable 561. SCSI Port Chassis IndexNamesCSIPortchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1000.60.1.1Descript

Página 81 - Table 191. System Properties

Syntax DellStatusAccess Read-onlyTable 566. SCSI Port Security StateNamesCSIPortSecurityStateObject ID 1.3.6.1.4.1.674.10892.1.1000.60.1.6Description

Página 82 - Table 195. Firmware Type

Description Defines the Parallel Port Table.Syntax IntegerParallelPortTableEntryAccess Not accessibleTable 571. Parallel Port Table EntryNameparallelP

Página 83

Table 575. Parallel Port State SettingsNameparallelPortStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.1000.70.1.4Description Defines the state and set

Página 84

Table 580. Parallel Port Connector Pin OutNameparallelPortConnectorPinOutObject ID 1.3.6.1.4.1.674.10892.1.1000.70.1.9Description Defines the pinout o

Página 85

Serial Port TableTable 585. Serial PortNameserialPortTableObject ID 1.3.6.1.4.1.674.10892.1.1000.80Description Defines the Serial Port Table.Syntax In

Página 86

Table 589. Serial Port State CapabilitiesNameserialPortStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1000.80.1.3Description Defines the capabilit

Página 87

Table 594. Serial Port NameNameserialPortNameObject ID 1.3.6.1.4.1.674.10892.1.1000.80.1.8Description Defines the name of the serial port.Syntax DellS

Página 88

Universal Serial Bus (USB) Port TableTable 599. Universal Serial Bus (USB) PortNameuSBPortTableObject ID 1.3.6.1.4.1.674.10892.1.1000.90Description De

Página 89 - System Resource Group

Syntax DellStateCapabilitiesAccess Read-onlyTable 604. USB Port State SettingsNameuSBPortStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.1000.90.1.4Des

Página 90

Access Read-onlyTable 11. UUID IndexName uUIDIndexObject ID 1.3.6.1.4.1.674.10892.1.300.20.1.2Description Defines the index of the UUID in a specif

Página 91 - System Resource Owner Table

Access Read-onlyPort Group Variable ValuesThis section includes definitions for server administrator-specific variable values used in this section.Tab

Página 92

connectorPortTypeIsUnknown(2)The keyboard port connector type is unknown.connectorPortTypeIsMiniDIN(3)The keyboard port connector type is a mini DIN.c

Página 93

connectorPortTypeIsSIMM(3)The memory device port connector type is a single in-line memory module (SIMM).connectorPortTypeIsSIP(4)The memory device po

Página 94

connectorPortTypeIsDIN68pin(5)The SCSI port connector type is a DIN 68-pin.183

Página 96

13Device GroupThe Device Group defines information about the devices discovered on the system during an inventory scan. Identifying information includ

Página 97

Syntax PointingDeviceTableEntryAccess Not accessibleIndexpointingDevicechassisIndex,pointingDeviceIndexTable 617. Pointing Device Chassis IndexNamepoi

Página 98

Syntax DellStatusAccess Read-onlyTable 622. Pointing Port Index ReferenceNamepointingPortIndexReferenceObject ID 1.3.6.1.4.1.674.10892.1.1100.10.1.6De

Página 99

Access Not accessibleIndexkeyboardDevicechassisIndex,keyboardDeviceIndexTable 627. Keyboard Device Chassis IndexNamekeyboardDevicechassisIndexObject I

Página 100

Access Read-onlyTable 632. Keyboard Port Index ReferenceNamekeyboardPortIndexReferenceObject ID 1.3.6.1.4.1.674.10892.1.1100.20.1.6Description Defines

Página 101

– USB Control Table– IDE Control Table– Diskette Control Table– Network Interface Control Table3. Variables that make up each table in the group — Thi

Página 102

IndexprocessorDevicechassisIndex,processorDeviceIndexTable 637. Processor Device Chassis IndexNameprocessorDevicechassisIndexObject ID 1.3.6.1.4.1.674

Página 103

Table 642. Processor Port Index ReferenceNameprocessorPortIndexReferenceObject ID 1.3.6.1.4.1.674.10892.1.1100.30.1.6Description Defines the index to

Página 104

Description Defines the maximum speed of the processor device in megahertz (MHz). A zero (0) indicates that the speed is unknown.Syntax DellUnsigned32

Página 105 - Power Group

Syntax DellStringAccess Read-onlyTable 653. Processor Device Core CountNameprocessorDeviceCoreCountObject ID 1.3.6.1.4.1.674.10892.1.1100.30.1.17Descr

Página 106 - Table 285. Power Unit Index

Access Read-onlyTable 657. Processor Device Extended CapabilitiesNameprocessorDeviceExtendedCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1100.30.1.21

Página 107 - Power Supply Table

Table 660. Processor Device Model NameNameprocessorDeviceModelNameObject ID 1.3.6.1.4.1.674.10892.1.1100.30.1.24Description Defines the model of the p

Página 108

Access Read-onlyTable 665. Processor Device Status IndexNameprocessorDeviceStatusIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.32.1.2Description Defines

Página 109 - Table 300. Power Supply Type

Table 670. Processor Device Status Location NameNameprocessorDeviceStatusLocationNameObject ID 1.3.6.1.4.1.674.10892.1.1100.32.1.7Description Defines

Página 110 - Voltage Probe Table

Syntax DellObjectRangeAccess Read-onlyTable 675. Cache Device IndexNamecacheDeviceIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.40.1.2Description Define

Página 111

Table 680. Cache Device TypeNamecacheDeviceTypeObject ID 1.3.6.1.4.1.674.10892.1.1100.40.1.7Description Defines the type of cache device.Syntax DellCa

Página 112 - Table 316. Voltage Probe Type

Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates

Página 113

All SNMP systems consist of one or more managed systems that provide data through an SNMP agent to a management system. The management system provides

Página 114 - Amerage Probe Table

Description Defines the maximum size of the cache device in kilobytes (KB). A zero (0) indicates that the size is unknown.Syntax DellUnsigned32BitRang

Página 115

Syntax DellCacheDeviceECCType (See Cache Device ECC Type)Access Read-onlyTable 691. Cache Device AssociativityNamecacheDeviceAssociativityObject ID 1.

Página 116

Syntax MemoryDeviceTableEntryAccess Not accessibleIndexmemoryDevicechassisIndex,memoryDeviceIndexTable 696. Memory Device Chassis IndexNamememoryDevic

Página 117

Syntax DellStatusAccess Read-onlyTable 701. Memory Device Memory Port Index ReferenceNamememoryDeviceMemoryPortIndexReferenceObject ID 1.3.6.1.4.1.674

Página 118 - AC Power Switch Table

Description Defines the bank location name of the memory device.Syntax DellStringAccess Read-onlyTable 706. Memory Device Type DetailsNamememoryDevice

Página 119

Access Read-onlyTable 711. Memory Device Total Bus WidthNamememoryDeviceTotalBusWidthObject ID 1.3.6.1.4.1.674.10892.1.1100.50.1.16Description Defines

Página 120 - AC Power Cord Table

Table 715. Memory Device Failure ModesNamememoryDeviceFailureModesObject ID 1.3.6.1.4.1.674.10892.1.1100.50.1.20Description Defines the failure modes

Página 121

Table 720. Memory Device Speed NameNamememoryDeviceSpeedNameObject ID 1.3.6.1.4.1.674.10892.1.1100.50.1.25Description This attribute defines the speed

Página 122 - Battery Table

IndexmemoryDeviceMappedAddresschassisIndex,memoryDeviceMappedAddressIndexTable 724. Memory Device Mapped Address Chassis IndexNamememoryDeviceMappedAd

Página 123 - Power Usage Table

Access Read-onlyTable 729. Memory Device Index ReferenceNamememoryDeviceIndexReferenceObject ID 1.3.6.1.4.1.674.10892.1.1100.60.1.6Description Defines

Página 124 - Table 376. Power Usage Index

ENTERPRISES(1)DELL (674)SNMPv2(6)In the preceding example, the OID prefix for the Dell enterprise would be 1.3.6.1.4.1.674.The numbers in boldface typ

Página 125 - Table 379. Power Usage Status

Access Read-onlyTable 734. Memory Device Mapped Address Ending AddressNamememoryDeviceMappedAddressEndingAddressObject ID 1.3.6.1.4.1.674.10892.1.1100

Página 126

Description Defines the index of the generic device in this chassis.Syntax DellObjectRangeAccess Read-onlyTable 739. Generic Device State Capabilities

Página 127

Table 744. Generic Device NameNamegenericDeviceNameObject ID 1.3.6.1.4.1.674.10892.1.1100.70.1.8Description Defines the name of the generic device.Syn

Página 128 - Power Profile Table

Access Read-onlyTable 749. PCI Device State CapabilitiesNamepCIDeviceStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1100.80.1.3Description Defines

Página 129

Table 754. PCI Device Manufacturer NameNamepCIDeviceManufacturerNameObject ID 1.3.6.1.4.1.674.10892.1.1100.80.1.8Description Defines the name of the P

Página 130 - Power Group Variable Values

Table 759. PCI Device Configuration Space Table EntryNamepCIDeviceConfigurationSpaceTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1100.82.1Description D

Página 131

Table 764. PCI Device Configuration Space StatusNamepCIDeviceConfigurationSpaceStatusObject ID 1.3.6.1.4.1.674.10892.1.1100.82.1.5Description Defines

Página 132

Description Defines the common configuration space header of the PCI device.Syntax Octet String (SIZE(0.1025))Access Read-onlyNetwork Device TableTabl

Página 133 - Table 413. Voltage Probe Type

Table 774. Network Device StatusNamenetworkDeviceStatusObject ID 1.3.6.1.4.1.674.10892.1.1100.90.1.3Description Defines the status of the network devi

Página 134

Description Defines the service name of the network device.Syntax DellStringAccess Read-onlyTable 780. Network Device Driver Image Path NameNamenetwor

Página 135

Two drawbacks to SNMP traps are that they are sent using UDP, which is not a guaranteed delivery mechanism, and that they are not acknowledged by the

Página 136 - Table 422. Battery Reading

Access Read-onlyTable 785. Network Device DHCP Server IP AddressNamenetworkDeviceDHCPServerIPAddressObject ID 1.3.6.1.4.1.674.10892.1.1100.90.1.14Desc

Página 137 - Table 425. Power Profile Type

Table 790. Network Device PCI Function NumberNamenetworkDevicePCIFunctionNumberObject ID 1.3.6.1.4.1.674.10892.1.1100.90.1.19Description Defines the P

Página 138

Description Defines if TOE is enabled for the network device.Syntax DellBooleanAccess Read-onlyTable 796. Network Device RDMA Capability FlagsNamenetw

Página 139 - Thermal Group

Managed System Services Device TableTable 800. Managed System Services Device TableNameObject ID 1.3.6.1.4.1.674.10892.1.1100.100Description Defines t

Página 140 - Table 432. Cooling Unit Index

Syntax DellStatusAccess Read-onlyTable 805. Managed System Services Device TypeNamemanagedSystemServicesDeviceTypeObject ID 1.3.6.1.4.1.674.10892.1.11

Página 141 - Cooling Device Table

Syntax SdCardUnitTableEntryAccess Not accessibleIndexsdCardUnitChassisIndex,sdCardUnitIndexTable 810. SD Card Unit Chassis IndexNamesdCardUnitChassisI

Página 142

Syntax DellStatusRedundancyAccess Read-onlyTable 815. SD Card Unit Count For RedundancyNamesdCardUnitCountForRedundancyObject ID 1.3.6.1.4.1.674.10892

Página 143

Access Not accessibleIndexsdCardDeviceChassisIndex,sdCardDeviceIndexTable 820. SD Card Device Chassis IndexNamesdCardDeviceChassisIndexObject ID 1.3.6

Página 144

Access Read-onlyTable 825. SD Card Device Config SettingsNamesdCardDeviceConfigSettingsObject ID 1.3.6.1.4.1.674.10892.1.1100.112.1.6Description Defin

Página 145 - Temperature Probe Table

Table 830. SD Card Device Unit Index ReferenceNamesdCardDeviceUnitIndexReferenceObject ID 1.3.6.1.4.1.674.10892.1.1100.112.1.11Description Defines the

Página 146

2Instrumentation MIB Version GroupThe Instrumentation Management Information Base (MIB) Version Group defines the attributes that identify the version

Página 147

deviceTypeIsATouchPad(7)Device type is a touch pad.Table 834. Processor Device Status StateVariable Name:DellProcessorDeviceStatusStateData Type:Integ

Página 148

deviceTypeIsMathProcessor(4)The processor device type is a math processor.deviceTypeIsDSP(5)The processor device type is a digital signal processor.de

Página 149 - Thermal Group Variable Values

processorUpgradeIsBySocket939(18)Upgrade is by Socket 939.processorUpgradeIsBySocketmPGA604(19)Upgrade is by Socket mPGA604.processorUpgradeIsBySocket

Página 150

deviceFamilyIsPentiumPro(12)The processor family is Pentium Pro.deviceFamilyIsPentium2(13)The processor family is Pentium II.deviceFamilyIsPentiumMMX(

Página 151 - User Security Group

deviceFamilyIsPowerPC604(36) The processor family is Power PC 604.deviceFamilyIsPowerPC620(37) The processor family is Power PC 620.deviceFamilyIsPowe

Página 152

deviceFamilyIsAMDOpteron6200 (61) The processor family is AMD Opteron 6200 Series Processor.deviceFamilyIsAMDOpteron4200 (62)The processor family is A

Página 153 - Remote Flash BIOS Group

deviceFamilyIsHobbit(112) The processor family is Hobbit.deviceFamilyIsCrusoe5000(120) The processor family is Crusoe 5000.deviceFamilyIsCrusoe3000(12

Página 154

deviceFamilyIsPA-RISC8500(145)The processor family is PA-RISC 8500.deviceFamilyIsPA-RISC8000(146)The processor family is PA-RISC 8000.deviceFamilyIsPA

Página 155

deviceFamilyIsQuadCoreIntelXeon7300(173)The processor family is Quad-Core Intel Xeon processor 7300 Series.deviceFamilyIsQuadCoreIntelXeon7400(174)The

Página 156

deviceFamilyIsIntelCore2DuoMob ile(196)The processor family is Intel Core2 Duo mobile processor.deviceFamilyIsIntelCore2SoloMo bile(197)The processor

Página 157 - Port Group

Syntax DellUnsigned8BitRangeAccess Read-only24

Página 158

deviceFamilyIsQuadCoreIntelXeo n5xxx(219)The processor family is Quad-Core Intel Xeon processor 5xxx Series.deviceFamilyIsDualCoreIntelXeo n7xxx(221)T

Página 159 - Keyboard Port Table

Table 839. Cache Device TypeVariable Name:DellCacheDeviceTypeData Type:IntegerPossible Data Values Meaning of Data ValuedeviceTypeIsOther(1)System cac

Página 160

deviceWritePolicyIsDeterminedByIO(6)Device write policy is determined by I/O query.Table 842. Cache Device Status StateVariable Name:DellCacheDeviceSt

Página 161 - Table 522. Keyboard Port Name

deviceAssociativityIsTwoWaySetAsso ciative(4)Device is two-way set associative.deviceAssociativityIsFourWaySetAsso ciative(5)Device is four-way set as

Página 162 - Processor Port Table

deviceSRAMTypeIsOther(1)Device SRAM type is not one of the following:deviceSRAMTypeIsUnknown(2)Device SRAM type is unknown.deviceSRAMTypeIsNonBurst(3)

Página 163

deviceFormFactorIsSRIMM(14)Device form factor is SRIMM.deviceFormFactorIsFBDIMM(15) Device form factor is FB-DIMM.Table 848. Memory Device TypeVariabl

Página 164 - Memory Device Port Table

deviceTypeIsDDR2FBDIMM(20) Device type is DDR2 FB-DIMM.deviceTypeIsDDR3(24)Device type is DDR3.deviceTypeIsFBD2(25)Device type is FBD2.Table 849. Memo

Página 165

Table 850. Generic Device TypeVariable Name:DellGenericDeviceTypeData Type:IntegerPossible Data Values Meaning of Data ValuedeviceTypeIsOther(1)Device

Página 166

connected(1)Media reports that device is connected.disconnected(2)Media reports that device is disconnected.driverBad(3)Driver cannot be opened to det

Página 167 - Monitor Port Table

Table 855. Network Device RDMA Capability FlagsVariable Name:DellNetworkDeviceRDMACapabilityFlagsData Type:IntegerNOTE: These values are bit fields, s

Página 168 - Table 551. Monitor Port Index

3Systems Management Software GroupThe Systems Management Software Group allows users to see information about the standards and software that are supp

Página 169 - Table 557. Monitor Port Name

Possible Data Values Meaning of Data Valueother(1)Device type is other.unknown(2)Device type is unknown.hypervisor(3)Device type is Hypervisor.vFlash(

Página 170 - Table 565. SCSI Port Status

standby(256)Device is in standby mode.Table 862. SD Card Device Card LicensedVariable Name:DellSDCardDeviceCardLicensedData Type:IntegerPossible Data

Página 172

14Slot GroupThe Slot Group provides information about the types of slots that your system supports. This management information base (MIB) group also

Página 173 - Table 579. Parallel Port Name

Table 866. System Slot IndexName systemSlotIndexObject ID 1.3.6.1.4.1.674.10892.1.1200.10.1.2Description Defines the index (one-based) of the system

Página 174

Table 871. System Slot TypeName systemSlotTypeObject ID 1.3.6.1.4.1.674.10892.1.1200.10.1.7Description Defines the type of the system slot.Syntax D

Página 175 - Serial Port Table

Table 876. System Slot Hot-Plug Bus WidthName systemSlotHotPlugBusWidthObject ID 1.3.6.1.4.1.674.10892.1.1200.10.1.12Description Defines the bus wid

Página 176 - Table 591. Serial Port Status

systemSlotHotPlugCanSignal PowerFault(16) Power on fault (and corresponding LED) can be detected due to a short or overcurrent.systemSlotHotPlugCanSig

Página 177 - Table 594. Serial Port Name

systemSlotHotPlugAdapterIsPresent (32) Adapter (card) present in slot (may not be powered).systemSlotHotPlugAdapterPresentAnd PoweredOn(36) Adapter (c

Página 178 - Table 602. USB Port Index

systemSlotIsPCMCIA(7) .The system slot is compliant with the Personal Computer Memory Card International Association (PCMCIA) standardssystemSlotIsVLV

Página 179 - Table 608. USB Port Name

Table 17. Systems Management Software Build NumberName systemManagementSoftwareBuildNumberObject ID 1.3.6.1.4.1.674.10892.1.100.3Description Defines

Página 180 - Port Group Variable Values

Table 882. System Slot UsageVariable Name: DellSystemSlotUsage Data Type: IntegerPossible Data Values Meaning of Data Value systemSlotUsageIsOther(1)

Página 181

busWidthIs16bits(4) The system slot bus width is 16 bits.busWidthIs32bits(5) The system slot bus width is 32 bits.busWidthIs64bits(6) The system slot

Página 183

15Memory GroupThe Memory Group provides information about the physical memory in your system. Variables in this group include error correction type, l

Página 184

Syntax PhysicalMemoryArrayTableEntryAccess Not accessibleTable 887. Physical Memory Array Table EntryNamephysicalMemoryArrayTableEntryObject ID 1.3.

Página 185 - Device Group

Table 891. Physical Memory Array State SettingsName physicalMemoryArrayStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.1300.10.1.4Description Defines

Página 186

Table 896. Physical Memory Array Maximum SizeName physicalMemoryArrayMaximumSizeObject ID 1.3.6.1.4.1.674.10892.1.1300.10.1.9Description Defines the

Página 187 - Keyboard Device Table

Table 901. Physical Memory Array ECC Error Noncritical ThresholdName physicalMemoryArrayECCErrorNonCriticalThresholdObject ID 1.3.6.1.4.1.674.10892.1

Página 188

Table 905. Physical Memory Array Mapped Chassis IndexName physicalMemoryArrayMappedchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1300.20.1.1Descripti

Página 189 - Processor Device Table

Table 910. Physical Memory Array Index ReferenceName physicalMemoryArrayIndexReferenceObject ID 1.3.6.1.4.1.674.10892.1.1300.20.1.6Description Defin

Página 190

Table 22. Systems Management Software URL NameName systemManagementSoftwareURLNameObject ID 1.3.6.1.4.1.674.10892.1.100.8Description Defines the uni

Página 191

Description Defines the Physical Memory Configuration Table.Syntax SEQUENCE OF PhysicalMemoryConfigTableEntryAccess Not accessibleTable 915. Physic

Página 192

Table 919. Physical Memory Configuration State SettingsName physicalMemoryConfigStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.4Descriptio

Página 193

Table 924. Physical Memory Configuration MOM SettingsName physicalMemoryConfigMOMSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.9Description D

Página 194

Table 928. Physical Memory Logging IndexNamephysicalMemoryLoggingIndexObject ID 1.3.6.1.4.1.674.10892.1.1300.40.1.2Description Defines the index (one-

Página 195 - Processor Device Status Table

Access Not accessibleTable 933. Redundant Memory Unit Table EntryName redundantMemoryUnitTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1300.50.1Descri

Página 196

Table 937. Redundant Memory Unit State SettingsName redundantMemoryUnitStatesettingsObject ID 1.3.6.1.4.1.674.10892.1.1300.50.1.4Description Defines

Página 197 - Cache Device Table

Description Defines the Physical Memory Card Table.Syntax SEQUENCE OF PhysicalMemoryCardTableEntryAccess Not accessibleTable 942. Physical Memory C

Página 198 - Table 675. Cache Device Index

Table 946. Physical Memory Card State SettingsName physicalMemoryCardStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.1300.60.1.4Description Defines t

Página 199

Access Read-onlyTable 951. Physical Memory Card Physical Memory Array Index ReferenceName physicalMemoryCardPhyMemArrayIndexReferenceObject ID 1.3.6

Página 200 - Table 687. Cache Device Speed

Table 953. Physical Memory Array ECC Type DefinitionsVariable Name: DellPhysicalMemoryArrayECCTypeData Type: IntegerPossible Data Values Meaning of D

Página 201 - Memory Device Table

Table 27. Systems Management Software Manufacturer NameName systemManagementSoftwareManufacturerNameObject ID 1.3.6.1.4.1.674.10892.1.100.13Descripti

Página 202

Table 956. Physical Memory Configuration Redundant CapabilitiesVariable Name: DellPhysicalMemoryConfigRedundantCapabilitiesData Type: IntegerPossible

Página 203 - Table 702. Memory Device Type

Table 959. Physical Memory Logging SettingsVariable Name: DellPhysicalMemoryLoggingSettings Data Type: IntegerPossible Data Values Meaning of Data Va

Página 205

16BIOS Setup Control GroupBasic Input/Output System (BIOS) Setup Control Group variables provide information about the functions that the BIOS perform

Página 206

Access Not accessibleIndex biosSetUpControlchassisIndexTable 962. BIOS Setup Control Chassis IndexName biosSetUpControlchassisIndexObject ID 1.3.6.1.4

Página 207 - Table 721. Memory Device Rank

Access Read-onlyTable 967. BIOS Setup Control Numeric Lock Control CapabilitiesNamebSUCnumLockControlCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.140

Página 208

Access Read-onlyTable 972. BIOS Setup Control Processor Serial Number Control SettingsName bSUCprocessorSerialNumberControlSettingsObject ID 1.3.6.1

Página 209

Access Read-onlyTable 977. BIOS Setup Control Speaker Control StatusName bSUCspeakerControlStatusObject ID 1.3.6.1.4.1.674.10892.1.1400.10.1.16Descr

Página 210 - Generic Device Table

Syntax DellStatusAccess Read-onlyTable 982. BIOS Setup Control NIF Wakeup on LAN Control NameName bSUCnIFwakeonLanControlNameObject ID 1.3.6.1.4.1.6

Página 211

Syntax DellStringAccess Read-onlyTable 987. BIOS Setup Control Administrator Password Control Capabilities UniqueName bSUCadministratorPasswordContr

Página 212 - PCI Device Table

4System State GroupThe Management Information Base (MIB) variables presented in this section enable you to track various attributes that describe the

Página 213 - Table 751. PCI Device Status

Description Defines the setup BIOS name of the new administrator password. To set a new administrator password, you must have successfully set the cu

Página 214 - Table 756. PCI Device Speed

Description Defines the setup BIOS name of the new user password. To set a new user password, a you must have successfully set the current user passw

Página 215

SCSI Control TableTable 1001. SCSI Control TableName sCSIControlTableObject ID 1.3.6.1.4.1.674.10892.1.1400.20Description Defines the Small Computer

Página 216

Syntax DellStateCapabilitiesAccess Read-onlyTable 1006. SCSI Control SettingsName sCSIControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.4

Página 217 - Network Device Table

Access Not accessibleIndex parallelPortControlchassisIndex,parallelPortControlIndexTable 1011. Parallel Port Control Chassis IndexName parallelPortCo

Página 218

Access Read-onlyTable 1016. Parallel Port Control NameName parallelPortControlNameObject ID 1.3.6.1.4.1.674.10892.1.1400.30.1.6Description Defines

Página 219

Index serialPortControlchassisIndex,serialPortControlIndexTable 1021. Serial Port Control Chassis IndexName serialPortControlchassisIndexObject ID 1.

Página 220

Table 1026. Serial Port Control NameName serialPortControlNameObject ID 1.3.6.1.4.1.674.10892.1.1400.40.1.6Description Defines the setup BIOS name o

Página 221

Syntax DellObjectRangeAccess Read-onlyTable 1031. USB Control CapabilitiesName usbControlCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1400.50.1.3D

Página 222

Access Not accessibleTable 1036. IDE Control Table EntryName ideControlTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1400.60.1Description Defines the

Página 223

Contents1 Introduction...

Página 224 - SD Card Unit Table

• systemStatePowerUnitStatusCombined• systemStateCoolingUnitStatusCombined• systemStateACPowerSwitchStatusCombined• systemStateRedundantMemoryUnitStat

Página 225 - Table 811. SD Card Unit Index

Access Read-onlyTable 1041. IDE Control StatusName ideControlStatusObject ID 1.3.6.1.4.1.674.10892.1.1400.60.1.5Description Defines the status for

Página 226 - SD Card Device Table

Description Defines the index (one-based) of this chassis.Syntax DellObjectRangeAccess Read-onlyTable 1046. Diskette Control IndexName disketteCont

Página 227

Network Interface Control TableThese MIB objects enable you to track the attributes of the NIC card for your system.Table 1051. Network Interface Cont

Página 228

Syntax DellNetworkInterfaceControlCapabilitiesUnique (See Network Interface Control Capabilities)Access Read-onlyTable 1056. Network Interface Contr

Página 229 - Device Group Variable Values

Table 1060. BIOS Setting Table EntryName biosSettingTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1400.90.1Description Defines the BIOS Setting Table

Página 230

Table 1065. BIOS Setting Value TypeName biosSettingValueTypeObject ID 1.3.6.1.4.1.674.10892.1.1400.90.1.5Description Defines the type of the BIOS set

Página 231

Description Defines the recommended display order of the BIOS setting within its BIOS setting group.Syntax DellUnsigned32BitRangeAccess Read-onlyTa

Página 232

unknown(1) Speaker control state is unknown.enabled(2)Speaker control is enabled.low(4) Speaker control volume is low.medium(8) Speaker control volume

Página 233

bootFromhardDriveFirstCapable (4) Setup BIOS can boot from an IDE hard drive first.bootFromDisketteORHardDrive FirstCapable(6) Setup BIOS can boot fro

Página 234

passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper.Table 1081. BIOS Password Control Setti

Página 235

Table 32. System State Table EntryName systemStateTableEntryObject ID 1.3.6.1.4.1.674.10892.1.200.10.1Description Defines the System State Table ent

Página 236

lpt2Capable(8) Setup BIOS can support parallel port 2.lpt2andEnableCapable(10) Setup BIOS has enabled parallel port 2.lpt3Capable(16) Setup BIOS can s

Página 237

enableCapable(2)Setup BIOS can enable the serial port.com1Capable(4)Setup BIOS can support serial port 1.enableAndCom1Capable(6)Setup BIOS can enable

Página 238

Table 1089. IDE Control CapabilitiesVariable Name: DellideControlCapabilitiesUnique Data Type: IntegerPossible Data Values Meaning of Data Valueunkno

Página 239

integer(1) Value type is integer.string(2) Value type is string.enumeration(3) Value type is enumeration.orderedList(4) Value type is ordered list.313

Página 241 - Table 840. Cache Device Level

17Local Response Agent GroupThe Local Response Agent Group provides information about various attributes of your system’s local response agent (LRA).

Página 242

Syntax LRAGlobalSettingsTableEntryAccess Not accessibleIndex lRAGlobalchassisIndexTable 1096. LRA Global Chassis IndexName lRAGlobalchassisIndexObje

Página 243

Description Defines the set of thermal shutdown capabilities that are supported by the LRA.Syntax DellLRAThermalShutdownCapabilitiesUniqueAccess Re

Página 244

Description Defines the index (one-based) of this chassis.Syntax DellObjectRangeAccess Read-onlyTable 1105. LRA Action Table Action Number IndexNam

Página 245 - Table 848. Memory Device Type

Syntax DisplayString (SIZE (0..256)Access Read-writeTable 1107. LRA Action Table Settings UniqueName lRAActionTableSettingsUniqueObject ID 1.3.6.1.

Página 246

Access Read-onlyTable 37. System State Power Unit State DetailsName systemStatePowerUnitStateDetailsObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.5Desc

Página 247

warningCapable(4) The LRA can carry out chassis-determined action(s) when a warning condition is detected.enableOnWarningCapable(6) The LRA enables ac

Página 248

18Cost of Ownership GroupThe Cost of Ownership (COO) Group provides a full set of cost-tracking objects, including fields for the computer’s manufactu

Página 249

Syntax CooTableEntryAccess Not accessibleIndexcoochassisIndexTable 1113. COO Chassis IndexNamecoochassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.10

Página 250

Syntax DellDateNameAccess Read-writeTable 1118. COO Acquisition Purchase OrderNamecooAquisitionPurchaseOrderObject ID 1.3.6.1.4.1.674.10892.1.1600.10.

Página 251

Access Read-onlyTable 1123. COO Cost Center Information Vendor NameNamecooCostCenterInformationVendorNameObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.1

Página 252

Access Read-writeTable 1128. COO Extended Warranty Provider NameNamecooExtendedWarrantyProviderNameObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.16Descr

Página 253 - Slot Group

Access Read-writeTable 1133. COO Deployment Duration TypeNamecooDeploymentDurationTypeObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.21Description Define

Página 254 - Table 869. System Slot Status

Access Read-writeTable 1138. COO Outsourcing Provider Fee NameNamecooOutsourcingProviderFeeNameObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.26Descripti

Página 255 - Table 873. System Slot Length

Access Read-writeTable 1143. COO Box Central Processing Unit (CPU) Serial Number NameNamecooBoxCPUSerialNumberNameObject ID 1.3.6.1.4.1.674.10892.1.16

Página 256 - System Slot Variable Values

Access Read-writeTable 1148. COO Depreciation Duration TypeNamecooDepreciationDurationTypeObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.36Description De

Página 257

Syntax Octet String (Size (1..128))Access Read-onlyTable 41. System State Power Supply Status CombinedName systemStatePowerSupplyStatusCombinedObjec

Página 258 - Table 881. System Slot Type

Description Defines the COO Service Contract Table.Syntax SEQUENCE OF CooServiceContractTableEntryAccess Not accessibleTable 1153. COO Service Contrac

Página 259

Table 1157. COO Service Contract Was RenewedNamecooServiceContractWasRenewedObject ID 1.3.6.1.4.1.674.10892.1.1600.20.1.4Description Specifies whether

Página 260 - Table 885. Hot-Plug Bus Width

Syntax cooCostEventLogTableEntryAccess Not accessibleIndexcooCostEventLogchassisIndex,cooCostEventLogIndexTable 1162. COO Cost Event Log Chassis Index

Página 261

Table 1166. COO Cost Event Log Duration TypeNamecooCostEventLogDurationTypeObject ID 1.3.6.1.4.1.674.10892.1.1600.30.1.5Description Defines the durati

Página 262

Table 1170. COO Warranty Chassis IndexNamecooWarrantychassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.40.1.1Description Defines the index (one-based

Página 263 - Memory Group

Table 1175. COO Warranty End Date NameNamecooWarrantyEndDateNameObject ID 1.3.6.1.4.1.674.10892.1.1600.40.1.6Description Defines the warranty end date

Página 264

Table 1179. COO Lease Information Chassis IndexNamecooLeaseInformationchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.50.1.1Description Defines the

Página 265

Table 1184. COO Lease Information Lease Rate FactorNamecooLeaseInformationLeaseRateFactorObject ID 1.3.6.1.4.1.674.10892.1.1600.50.1.6Description Defi

Página 266

Access Not accessibleTable 1189. COO Schedule Number Table EntryNamecooScheduleNumberTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1600.60.1Description

Página 267

Description Defines the lease information index number to reference the schedule number.Syntax DellUnsigned32BitRangeAccess Read-writeTable 1194. COO

Página 268

Table 45. System State Voltage Status DetailsName systemStateVoltageStatusDetailsObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.13Description Defines th

Página 269

Access Read-onlyTable 1198. COO Options IndexName cooOptionsIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.70.1.2Description Defines the index (one-based

Página 270

Syntax SEQUENCE OF CooMaintenanceTableEntryAccess Not accessibleTable 1203. COO Maintenance Table EntryNamecooMaintenanceTableEntryObject ID 1.3.6.1.4

Página 271

Table 1207. COO Maintenance Start Date NameNamecooMaintenanceStartDateNameObject ID 1.3.6.1.4.1.674.10892.1.1600.80.1.4Description Defines the start d

Página 272 - Physical Memory Logging Table

Access Not accessibleTable 1212. COO Repair Table EntryNamecooRepairTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1600.90.1Description Defines the COO R

Página 273 - Redundant Memory Unit Table

Description Defines the number of repairs that this system has undergone.Syntax DellCostofOwnershipStringAccess Read-writeTable 1217. COO Repair Vendo

Página 274

Access Read-onlyTable 1221. COO Support Information IndexName cooSupportInformationIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.100.1.2Description Defi

Página 275 - Physical Memory Card Table

Access Read-writeTable 1226. COO Support Information Fix Type NameName cooSupportInformationFixTypeNameObject ID 1.3.6.1.4.1.674.10892.1.1600.100.1.7D

Página 276

Table 1230. COO Trouble Ticket IndexNamecooTroubleTicketIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.110.1.2Description Defines the index (one-based) o

Página 277

unknown(2)The ownership code is unknown.owned(3)The ownership code is owned.leased(4)The ownership code is leased.rented(5)The ownership code is rente

Página 278 - Memory Group Variable Values

19Remote Access GroupThe Remote Access Group provides information about the remote access hardware that may be present in your system. In addition to

Página 279

Table 49. System State Cooling Unit State DetailsName statesystemStateCoolingUnitStateDetailsObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.17Description

Página 280

Access Read-onlyTable 1241. Remote Access Adapter IndexNameremoteAccessAdapterIndexObject ID 1.3.6.1.4.1.674.10892.1.1700.10.1.2Description Defines th

Página 281

Table 1246. Remote Access Product Info NameNameremoteAccessProductInfoNameObject ID 1.3.6.1.4.1.674.10892.1.1700.10.1.7Description Defines the name of

Página 282

Description Defines the static IP address to be used by the integrated NIC provided by the remote access hardware.Syntax IpAddressAccess Read-writeTab

Página 283 - BIOS Setup Control Group

Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware.Syntax IpAddressAccess Read-onlyT

Página 284

Table 1261. Remote Access TypeVariable Name:DellRemoteAccessTypeData Type:IntegerPossible Data Values Meaning of Data ValueremoteAccessTypeIsOther(1)T

Página 285

hardReset(4)The remote access hardware performs a hard reset.softReset(8)The remote access hardware performs a soft reset.gracefulReset(16)The remote

Página 286

none(0)The remote access hardware has no LAN capabilities.unknownCapabilities(1)The remote access hardware LAN capabilities are unknown.nicCapable(2)T

Página 287

smtpEmailEnabled(2)The remote access hardware SMTP client is enabled for sending e-mail.tftpRemoteFloppyEnabled(4)The remote access hardware TFTP clie

Página 288

numericPagerCapable(8)The admin user supports numeric paging.alphaPagerCapable(16)The admin user supports alphanumeric paging.emailCapable(32)The admi

Página 289

numericPagerTest(2)A numeric pager test is performed for the admin user.alphaPagerTest(4)An alphanumeric pager test is performed for the admin user.em

Página 290

Access Read-onlyTable 53. System State Cooling Device Status CombinedName systemStateCoolingDeviceStatusCombinedObject ID 1.3.6.1.4.1.674.10892.1.20

Página 291

Table 1279. Remote SNMP Trap State SettingsVariable Name:DellRemoteSNMPTrapStateSettingsData Type:IntegerPossible Data Values Meaning of Data Valuenon

Página 292 - SCSI Control Table

dialInCapable(8)The dial-up functionality can support the dial-in feature.dialOutCapable(16)The dial-up functionality can support the dial-out feature

Página 293 - Parallel Port Control Table

remoteDialUpIsOther(1)The remote dial type is not one of the following:remoteDialUpIsUnknown(2)The remote dial type is unknown.remoteDialUpIsTone(3)Th

Página 294

none(0)The dial-out destination has no state capabilities.unknownCapabilities(1)The dial-out destination state capabilities are unknown.enableCapable(

Página 296

20Cluster Group Clustering combines multiple systems in such a way that they provide services a single system cannot. Clustering enhances higher avail

Página 297 - USB Control Table

Description Defines the index (one-based) of this chassis.Syntax DellObjectRangeAccess Read-onlyTable 1292. Cluster IndexNameclusterIndexObject ID 1.3

Página 298 - IDE Control Table

Table 1297. Cluster Type Description NameNameclusterTypeDescriptionNameObject ID 1.3.6.1.4.1.674.10892.1.1800.10.1.7Description Defines the descriptio

Página 300 - Diskette Control Table

21Baseboard Management Controller GroupThe Baseboard Management Controller (BMC) monitors the system for critical events by communicating with various

Página 301

Syntax DellStatusAccess Read-onlyTable 57. System State Temperature Status DetailsName systemStateTemperatureStatusDetailslyObject ID 1.3.6.1.4.1.6

Página 302

,bmcIndexTable 1302. BMC Chassis IndexNamebmcChassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1900.10.1.1Description Defines the index (one-based) of the

Página 303 - BIOS Setting Table

Table 1307. BMC Display NameNamebmcDisplayNameObject ID 1.3.6.1.4.1.674.10892.1.1900.10.1.6Description Defines the display name of the BMC.Syntax Dell

Página 304 - Table 1063. BIOS Setting Name

Description Defines the module name for the BMC. The module name is present only on certain systems, such as modular systems.Syntax DellStringAccess R

Página 305

,bmcSerialInterfaceIndexTable 1317. BMC Serial Interface Chassis IndexNamebmcSerialInterfaceChassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1900.20.1.1D

Página 306 - BIOS Group Variable Values

Table 1322. BMC Serial Interface StatusNamebmcSerialInterfaceStatusObject ID 1.3.6.1.4.1.674.10892.1.1900.20.1.6Description Defines the status of the

Página 307

Description Defines the bit rate of the BMC serial interface.Syntax DellBMCSerialBitRateTypeAccess Read-onlyBaseboard Management Controller LAN Interf

Página 308

Access Read-onlyTable 1332. BMC LAN Interface IndexNamebmcLANInterfaceIndexObject ID 1.3.6.1.4.1.674.10892.1.1900.30.1.3Description Defines the index

Página 309

Table 1337. BMC LAN Interface IP Address SourceNamebmcLANInterfaceIPAddressSourceObject ID 1.3.6.1.4.1.674.10892.1.1900.30.1.8Description Defines the

Página 310

Description Defines the SNMP community used for BMC LAN alerts (traps) sent on the BMC LAN interface.Syntax DisplayString (SIZE (0..32))Access Read-on

Página 311

Table 1345. BMC Serial Flow Control TypeVariable Name:DellBMCSerialFlowControlTypeData Type:IntegerPossible Data Values Meaning of Data Value-- none(0

Página 312

Syntax Octet String (Size(1..128)Access Read-onlyTable 61. System State Chassis Intrusion State DetailsName systemStateChassisIntrusionStateDetailsO

Página 313

iDRAC6(10)Controller type is Integrated Dell Remote Access Controller 6.iDRAC6Modular(11)Controller type is Integrated Dell Remote Access Controller 6

Página 314

22Field Replaceable Unit GroupA field replaceable unit (FRU) is a part that can be removed and replaced without having to send the system to a repair

Página 315 - Local Response Agent Group

Table 1352. FRU IndexName fruIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.2Description Defines the index (one-based) of the FRU.Syntax DellObj

Página 316 - Table 1097. LRA Global State

Description Defines the serial number of the FRU.Syntax DisplayString (SIZE (0..64))Access Read-onlyTable 1358. FRU Part Number NameName fruPartNum

Página 317 - LRA Action Table

Possible Data Values Meaning of Data Value ok(1) FRU information is okay.notSupported(2) FRU information is not supported.notAvailable(3) FRU informa

Página 318

23Storage Management GroupThe Storage Management Group is composed of the following:• Storage Management Group—information about the software product

Página 319

Syntax IntegerAccess Read-onlyTable 1365. Software ManufacturerName softwareManufacturerObject ID 1.3.6.1.4.1.674.10893.1.20.3Description Identifi

Página 320

Table 1369. DescriptionName descriptionObject ID 1.3.6.1.4.1.674.10893.1.20.100.2Description Provides a short description of this management softwar

Página 321 - Cost of Ownership Group

Syntax IntegerAccess Read-onlyTable 1374. Agent Time StampName agentTimeStampObject ID 1.3.6.1.4.1.674.10893.1.20.110.3Description Identifies the

Página 322 - Table 1114. COO State

Table 1378. Agent HostnameName agentHostnameObject ID 1.3.6.1.4.1.674.10893.1.20.110.7Description This entry is obsolete for Storage Management.Synt

Página 323

Description Defines the individual state of all AC power switches in this chassis. The first byte returned represents the state of the first AC power

Página 324

Table 1383. Agent Management Software URL NameName agentManagementSoftwareURLNameObject ID 1.3.6.1.4.1.674.10893.1.20.110.12Description Identifies t

Página 325

Access Read-onlyTable 1386. Agent Smart Thermal ShutdownName agentSmartThermalShutdownObject ID 1.3.6.1.4.1.674.10893.1.20.110.15Description Indica

Página 326 - Table 1134. COO Training Name

• Battery Connection Table — describes the connection between each battery on the managed system and its controller. Each controller number in the tab

Página 327

Syntax DisplayStringAccess Read-onlyTable 1391. Controller VendorName controllerVendorObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.3Description Id

Página 328

Table 1394. Controller SeverityName controllerSeverityObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.6Description This entry is obsolete for Storage M

Página 329 - COO Service Contract Table

Access Read-onlyTable 1398. Controller Physical Device CountName controllerPhysicalDeviceCountObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.11Descrip

Página 330

Access Read-onlyTable 1403. Controller Memory Size in BytesName controllerMemorySizeInBytesObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.16Descriptio

Página 331 - COO Cost Event Log Table

Access Read-onlyTable 1408. Controller C0 Port 0 IDName controllerC0Port0IDObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.21Description This entry is

Página 332

Access Read-onlyTable 1413. Controller C1 Port 0 World Wide NameName controllerC1Port0WWNObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.26Description

Página 333 - COO Warranty Table

Access Read-onlyTable 1418. Controller C1 Operating System ControllerName controllerC1OSControllerObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.31Des

Página 334

5 Chassis Information Group... 45Chassis Informatio

Página 335 - COO Lease Information Table

Access Read-onlyTable 69. System State AC Power Cord Status DetailsName systemStateACPowerCordStatusDetailsObject ID 1.3.6.1.4.1.674.10892.1.200.10.

Página 336

Access Read-onlyTable 1423. Controller Battery Charge CountName controllerBatteryChargeCountObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.36Descripti

Página 337 - COO Schedule Number Table

Table 1426. Controller Nexus IDName controllerNexusIDObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.39Description Durable unique ID for this controlle

Página 338

Possible values:1: Enabled2: Disabled3: Active (enabled and active)99: Not ApplicableSyntax IntegerAccess Read-onlyTable 1431. Controller Minimum Fi

Página 339 - COO Options Table

Table 1435. Controller Reconstruct RateName controllerReconstructRateObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.48Description The rate for reconst

Página 340 - COO Maintenance Table

Table 1440. Controller Patrol Read StateName controllerPatrolReadStateObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.53Description The state of the pa

Página 341

Description Indicates encryption capability of the controller. Value: 1 - Capable, 99 - Not ApplicableSyntax IntegerAccess Read-onlyName controller

Página 342 - COO Repair Table

Table 1448. Controller Spin Down Time IntervalName controllerSpinDownTimeIntervalObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.62Description Shows th

Página 343 - Table 1215. COO Repair State

Description Indicates controller capability for automatic power saving. Value: 0 - Disabled, 1 - Enabled, 99 - UndeterminedSyntax IntegerAccess Rea

Página 344 - COO Support Information Table

Table 1456. Channel TableName channelTableObject ID 1.3.6.1.4.1.674.10893.1.20.130.2Description Defines the channel table.Syntax SEQUENCE OF Channe

Página 345

2: Failed3: Online4: Offline - The I/O has paused.6: DegradedSyntax IntegerAccess Read-onlyTable 1461. Channel SeverityName channelSeverityObject ID

Página 346 - COO Trouble Ticket Table

Access Read-onlyTable 73. System State Event Log StatusName systemStateEventLogStatusObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.41Description Defin

Página 347

Possible values:1: Other2: Unknown3: OK4: Non-critical5: Critical6: Non-recoverableSyntax DellStatusAccess Read-onlyTable 1465. Channel Component St

Página 348

Table 1468. Channel Bus TypeName channelBusTypeObject ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.11Description The bus type of the channel.Possible value

Página 349 - Remote Access Group

Description Identifies the instance number of the enclosure entry.Syntax IntegerAccess Read-onlyTable 1472. Enclosure NameName enclosureNameObject

Página 350

Syntax IntegerAccess Read-onlyTable 1476. Enclosure IDName enclosureIDObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.6Description Represents unique

Página 351

Access Read-onlyTable 1481. Enclosure Split Bus Part NumberName enclosureSplitBusPartNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.11Descriptio

Página 352

Access Read-onlyTable 1486. Enclosure TypeName enclosureTypeObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.16Description Indicates the type of the en

Página 353 - Remote Access Variable Values

Table 1489. Enclosure Channel NumberName enclosureChannelNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.19Description Identifies the channel num

Página 354

Possible values:1: Other2: Unknown3: OK4: Non-critical5: Critical6: Non-recoverableSyntax DellStatusAccess Read-onlyTable 1494. Enclosure Component

Página 355

Table 1497. Enclosure SCSI RateName enclosureSCSIRateObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.27Description Actual SCSI rate in the enclosure.Sy

Página 356

Table 1502. Enclosure Total SlotsName enclosureTotalSlotsObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.32Description Shows the total number of physic

Página 357

Description Lists the status of each cooling unit of this chassis. The results are returned as a binary octet string where each byte of the octet str

Página 358

Table 1506. Array Disk NumberName arrayDiskNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.1Description Identifies the instance number of the arr

Página 359

24: Rebuild25: No Media - CD-ROM or removable disk has no media.26: Formatting - In the process of formatting.28: Diagnostics - Diagnostics are runnin

Página 360

Table 1513. Array Disk RevisionName arrayDiskRevisionObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.8Description Identifies the firmware version of th

Página 361 - not ready

Table 1518. Array Disk Largest Contiguous Free Space in MegabytesName arrayDiskLargestContiguousFreeSpaceInMBObject ID 1.3.6.1.4.1.674.10893.1.20.130

Página 362

Access Read-onlyTable 1523. Array Disk Used Space in BytesName arrayDiskUsedSpaceInBytesObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.18Description

Página 363

8: SAS9: PCIeSyntax IntegerAccess Read-onlyTable 1527. Array Disk Spare StateName arrayDiskSpareStateObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.2

Página 364

2: Unknown3: OK4: Non-critical5: Critical6: Non-recoverableSyntax DellStatusAccess Read-onlyTable 1530. Array Disk Device NameName arrayDiskDeviceNa

Página 365 - Cluster Group

Table 1534. Array Disk Negotiated SpeedName arrayDiskNegotiatedSpeedObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.29Description Indicates the speed a

Página 366 - Table 1296. Cluster Type

Description Indicates the week (1 through 53) in which this disk was manufactured.Syntax DisplayStringAccess Read-onlyTable 1539. Array Disk Manufa

Página 367 - Cluster Group Variable Values

Table 1543. Array Disk Alta Product IdName arrayDiskAltaProductIdObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.38Description Provides product ID for

Página 368

Syntax Octet String (Size(1..128))Access Read-onlyTable 82. System State Processor Device Status CombinedName systemStateProcessorDeviceStatusCombin

Página 369 - Table 1301. BMC Table Entry

Access Read-onlyTable 1548. Array Disk Drive Write CacheName arrayDiskDriveWriteCacheObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.43Description Ind

Página 370 - Table 1306. BMC Status

-1: Not Available / Not Applicable1: Drive Health Good2: Approaching Warranty Coverage Expiry3: Warranty Coverage Expired4: Approaching Read Only5: Re

Página 371

Syntax SEQUENCE OF ArrayDiskEnclosureConnectionEntryAccess Not accessibleTable 1556. Array Disk Enclosure Connection EntryName arrayDiskEnclosureCon

Página 372 - Table 1314. BMC IPv6 URL Name

Description Identifies the name of the enclosure as represented in Storage Management to which this array disk belongs.Syntax DisplayStringAccess R

Página 373

NOTE: Only array disks that are NOT part of an enclosure are listed in this table. Backplanes are considered enclosures by Storage Management.The foll

Página 374

Fan TableThis table describes available properties for each fan on the managed system.The following object sets up the Fan Table.Table 1573. Fan Table

Página 375 - Table 1328. BMC LAN Interface

Description Identifies the fan's (re)seller's name.Syntax DisplayStringAccess Read-onlyTable 1578. Fan StateName fanStateObject ID 1.3.6.

Página 376

Description This entry is obsolete. This setting is not supported by fans managed under Storage Management.Syntax DisplayStringAccess Read-onlyTabl

Página 377

Table 1586. Fan1 Part NumberName fan1PartNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.12Description Identifies the part number of the fan in the

Página 378

4: Non-critical5: Critical6: Non-recoverableSyntax DellStatusAccess Read-onlyTable 1590. Fan Nexus IDNamefanNexusIDObject ID 1.3.6.1.4.1.674.10893.1

Página 379

Table 86. System State SD Card Unit Status CombinedName systemStateSDCardUnitStatusCombinedObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.54Description

Página 380

Access Not accessibleIndexfanConnectionNumberTable 1594. Fan Connection NumberNamefanConnectionNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.1Des

Página 381 - Field Replaceable Unit Group

Description Identifies the instance number of the enclosure in the enclosureTable to which this fan belongs.Syntax IntegerAccess Read-onlyPower Supp

Página 382

Description Defines the capabilities of the power supply.Syntax DellPowerSupplyStateCapabilitiesUnique (Power Supply State Capabilities Unique)Acces

Página 383 - Table 1359. FRU Revision Name

Access Read-onlyTable 1609. Power Supply Input VoltageName powerSupplyInputVoltageObject ID 1.3.6.1.4.1.674.10892.1.600.12.1.9Description Defines t

Página 384

Table 1614. Power Supply Rated Input WattageName powerSupplyRatedInputWattageObject ID 1.3.6.1.4.1.674.10892.1.600.12.1.14Description Defines the ra

Página 385 - Storage Management Group

Description Identifies the name of the power supply in this connection as represented in Storage Management.Syntax DisplayStringAccess Read-onlyTab

Página 386 - Table 1368. Display Name

Temperature Probe TableTable 1623. Temperature Probe TableName temperatureProbeTableObject ID 1.3.6.1.4.1.674.10892.1.700.20Description Defines the

Página 387 - Global Data Group

Syntax DellStateCapabilitiesAccess Read-onlyTable 1628. Temperature Probe State SettingsName temperatureProbeStateSettingsObject ID 1.3.6.1.4.1.674

Página 388 - Table 1376. Agent Modifiers

Syntax DellStringAccess Read-onlyTable 1633. Temperature Probe Upper Nonrecoverable ThresholdName temperatureProbeUpperNonRecoverableThresholdObject

Página 389 - Table 1382. Agent MIB Version

Access Read-onlyTable 1638. Temperature Probe Lower Nonrecoverable ThresholdName temperatureProbeLowerNonRecoverableThresholdObject ID 1.3.6.1.4.1.6

Página 390

5Chassis Information GroupThe Chassis Information Group objects provide information about the modular chassis in which a blade system resides.NOTE: Th

Página 391 - Physical Devices Group

Table 1642. Temperature Probe Connection EntryName temperatureConnectionEntryObject ID 1.3.6.1.4.1.674.10893.1.20.130.12.1Description Defines the te

Página 392 - Controller Table

Syntax DisplayStringAccess Read-onlyTable 1647. Temperature Probe Connection Enclosure NumberName temperatureConnectionEnclosureNumberObject ID 1.3

Página 393 - Table 1393. Controller State

Table 1651. Enclosure Management Module NameName enclosureManagementModuleNameObject ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.2Description Identifies

Página 394

Table 1655. Enclosure Management Module Part NumberName enclosureManagementModulePartNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.6Description

Página 395

Possible values:1: Other2: Unknown3: OK4: Non-critical5: Critical6: Non-recoverableSyntax DellStatusAccess Read-onlyTable 1660. Enclosure Management

Página 396

Enclosure Management Module Connection TableThis table describes the connection between each enclosure management module on the managed system and its

Página 397

Table 1667. Enclosure Management Module Connection EMM NumberName enclosureManagementModuleConnectionEMMNumberObject ID 1.3.6.1.4.1.674.10893.1.20.13

Página 398

Access Not accessibleIndex batteryChassisIndex , batteryIndexTable 1672. Battery Chassis IndexName batteryChassisIndexObject ID 1.3.6.1.4.1.674.108

Página 399

Table 1677. Battery ReadingName batteryReadingObject ID 1.3.6.1.4.1.674.10892.1.600.50.1.6Description Defines the reading of the battery.Syntax Del

Página 400

Description Identifies the instance number of the battery connection entry.Syntax IntegerAccess Read-onlyTable 1682. Battery Connection Battery Nam

Página 401

Chassis Information Table EntryName chassisInformationTableEntryObject ID 1.3.6.1.4.1.674.10892.1.300.10.1Description Defines the chassis informatio

Página 402

The following object sets up the Tape Drive Table.Table 1686. Tape Drive TableNametapeDriveTableObject ID 1.3.6.1.4.1.674.10893.1.20.130.17Description

Página 403

Syntax DisplayStringAccess Read-onlyTable 1691. Tape Drive Product IDName tapeDriveProductIDObject ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.4Descript

Página 404

Syntax INTEGERAccess Read-onlyLogical Devices GroupThe Logical Devices Management Information Base (MIB) group provides information about the logica

Página 405

Syntax INTEGERAccess Read-onlyTable 1699. Virtual Disk NameName virtualDiskNameObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.2Description Identifie

Página 406

54: Degraded RedundancySyntax INTEGERAccess Read-onlyTable 1702. Virtual Disk SeverityName virtualDiskSeverityObject ID 1.3.6.1.4.1.674.10893.1.20.1

Página 407 - Channel Table

Table 1706. Virtual Disk Free Space in BytesName virtualDiskFreeSpaceInBytesObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.9Description This entry is

Página 408 - Table 1460. Channel State

Table 1709. Virtual Disk Cache PolicyName virtualDiskCachePolicyObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.12Description Indicates whether the cont

Página 409 - Table 1463. Channel SCSI ID

Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management.Syntax INTEGERAccess Read-onlyT

Página 410 - Table 1467. Channel Data Rate

Description The status of the virtual disk itself without the propagation of any contained component status.Possible values:1: Other2: Unknown3: OK4:

Página 411 - Enclosure Table

Table 1721. Virtual Disk EncryptedName virtualDiskEncryptedObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.24Description Indicates if virtual disk is e

Página 412 - Table 1474. Enclosure State

Chassis Parent Index ReferenceName chassisparentIndexReferenceObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.4Description Defines the index (one-based)

Página 413 - Table 1476. Enclosure ID

Description A table of managed virtual disk partitions. The number of entries is related to number of partitions discovered in the system. The maximum

Página 414

Access Read-onlyTable 1730. Virtual Disk Partition SizeNamevirtualDiskPartitionSizeObject ID 1.3.6.1.4.1.674.10893.1.20.140.2.1.4Description Size of

Página 415 - Table 1486. Enclosure Type

Description An entry in the Fluid Cache table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.Syntax Flu

Página 416 - Table 1492. Enclosure SCSI ID

Syntax OCTET STRINGAccess Read-onlyTable 1740. Fluid Cache License DurationNamefluidCacheLicenseDurationObject ID 1.3.6.1.4.1.674.10893.1.20.140.4.1

Página 417

Table 1745. Fluid Cache License Product IDNamefluidCacheLicenseProductIdObject ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.11Description Indicates the produ

Página 418

Description Indicates the unique ID of the fluid cache component.Syntax OCTET STRINGAccess Read-onlyFluid Cache DiskTable 1751. Fluid Cache Disk Tab

Página 419 - Array Disk Table

Access Read-onlyTable 1756. Fluid Cache Disk Backend Device TypeNamefluidCacheDiskBackendDeviceTypeObject ID 1.3.6.1.4.1.674.10893.1.20.140.5.1.4Desc

Página 420 - Table 1509. Array Disk State

DescriptionConfigured Mode of the FluidCache. The values are :• 0 - Writeback mode• 1 - Writethrough mode• 2 - PassThrough modeSyntax INTEGERAccess

Página 421

Syntax FluidCachePoolEntryAccess Not-AccessibleTable 1765. Fluid Cache Pool NumberName fluidCacheDiskNumberObject ID 1.3.6.1.4.1.674.10893.1.20.140

Página 422

Table 1770. Fluid Cache Pool High Availability StateNamefluidCachePoolHighAvailabilityStateObject ID 1.3.6.1.4.1.674.10893.1.20.140.6.1.6Description I

Página 423 - Table 1521. Array Disk LUN ID

Chassis Asset Tag NameName chassisAssetTagNameObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.10Description Defines the user-assigned asset tag name for

Página 424

Access Not accessibleTable 1774. Array Disk Logical Connection EntryName arrayDiskLogicalConnectionEntryObject ID 1.3.6.1.4.1.674.10893.1.20.140.3.1

Página 425

Access Read-onlyTable 1779. Array Disk Logical Connection Virtual Disk NumberName arrayDiskLogicalConnectionVirtualDiskNumberObject ID 1.3.6.1.4.1.6

Página 426

Table 1783. Description EventName descriptionEventObject ID 1.3.6.1.4.1.674.10893.1.20.200.2Description Storage Management event message text descri

Página 427

Table 1788. Current Status EventName currentStatusEventObject ID 1.3.6.1.4.1.674.10893.1.20.200.7Description Current status of object causing the al

Página 429

24Change Management GroupThe Change Management Group lets you monitor information about the Dell devices and software that are present on a particular

Página 430

Device Group TableThe following object sets up the Device Group Table.Table 1793. Device TableNamedeviceTableObject ID 1.3.6.1.4.1.674.10899.1.5Descri

Página 431

Table 1798. Device Vendor IDNamedeviceVendorIDObject ID 1.3.6.1.4.1.674.10899.1.5.1.4Description Defines the ID for the vendor supplying the device.Sy

Página 432

Table 1802. Application TableNameapplicationTableObject ID 1.3.6.1.4.1.674.10899.1.6Description Defines a table of application information for the sys

Página 433

Description Identifies the version of the application.Syntax DisplayStringAccess Read-onlyTable 1808. Application Display StringNameaplicationDisplayS

Página 434

Chassis System NameName chassisSystemNameObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.15Description Defines the system name of this chassis.Syntax De

Página 436 - Table 1580. Fan Probe Unit

25Dell Remote Access Controller Out-of-Band GroupThe Dell Remote Access Controller Out-of-Band MIB contains information for both Chassis Management Co

Página 437

Access Read-onlyTable 1814. DRsProductVersionNamedrsProductVersionObject ID 1.3.6.1.4.1.674.10892.2.1.1.5Description Defines the product version of a

Página 438 - Table 1587. Fan 2 Part Number

Table 1819. DRsProductChassisNameNamedrsProductChassisNameObject ID 1.3.6.1.4.1.674.10892.2.1.1.10Description Defines the name of the chassis.Syntax D

Página 439 - Fan Connection Table

Description Defines the data center locator of the chassis.Syntax DellStringAccess Read-onlyTable 1825. DRsProductChassisAisleNamedrsProductChassisAis

Página 440

Table 1830. DRsProductChassisSystemIDNamedrsProductChassisSystemIDObject ID 1.3.6.1.4.1.674.10892.2.1.1.21Description Defines the system ID of the cha

Página 441

Table 1835. DRsGlobalCurrStatusNamedrsGlobalCurrStatusObject ID 1.3.6.1.4.1.674.10892.2.3.1.1Description Defines the overall chassis status being moni

Página 442 - Table 1607. Power Supply Type

Table 1840. DRsFanCurrStatusNamedrsFanCurrStatusObject ID 1.3.6.1.4.1.674.10892.2.3.1.6Description Defines the fan subsystem health status being monit

Página 443

Table 1845. DRsCMAmbientTemperatureNamedrsCMCAmbientTemperatureObject ID 1.3.6.1.4.1.674.10892.2.3.1.11Description Defines the ambient temperature rea

Página 444 - Power Supply Connection Table

Table 1850. DRsRedPrevStatusNamedrsRedPrevStatusObject ID 1.3.6.1.4.1.674.10892.2.3.2.4Description Defines the previous redundancy status recorded by

Página 445

Cooling Device Table...

Página 446

Chassis System User Phone Number NameName chassisSystemUserPhoneNumberNameObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.20Description Defines the user-

Página 447

Table 1855. DRsCMCPrevStatusNamedrsCMCPrevStatusObject ID 1.3.6.1.4.1.674.10892.2.3.2.9Description Defines the CMC health status being monitored by th

Página 448

Description Defines the timestamp of the most recent power health status change.Syntax TimeTicksAccess Read-onlyTable 1861. DRsFanChangeTimeNamedrsFan

Página 449

Description Defines the CMC power table.Syntax SEQUENCE OF DrsCMCPowerTableEntryAccess Not-accessibleTable 1866. DRsCMC Power Table EntryNamedrsCMCPow

Página 450

Description Defines the power (in watts) required by the chassis infrastructure, along with the maximum power requirements for all systems currently t

Página 451

Syntax DellTimestampAccess Read-onlyTable 1876. DRsWattsPeakUsageNamedrsWattsPeakUsageObject ID 1.3.6.1.4.1.674.10892.2.4.1.1.8Description Defines the

Página 452

Table 1881. DRsWattsReadingNamedrsWattsReadingObject ID 1.3.6.1.4.1.674.10892.2.4.1.1.13Description Defines the instantaneous chassis power usage (in

Página 453

Table 1886. DRsPSUMonitoringCapableNamedrsPSUMonitoringCapableObject ID 1.3.6.1.4.1.674.10892.2.4.2.1.4Description Defines the monitoring capabilities

Página 454

Table 1891. DRsCMCServerTableEntryNamedrsCMCServerTableEntryObject ID 1.3.6.1.4.1.674.10892.2.5.1.1Description Defines the CMC server table entry.Synt

Página 455

Access Read-onlyTable 1896. DRsServerSlotNumberNamedrsServerSlotNumberObject ID 1.3.6.1.4.1.674.10892.2.5.1.1.5Description Defines the chassis slot nu

Página 456

Access Read-onlyTable 1901. DrsCAMessageNamedrsCAMessageObject ID 1.3.6.1.4.1.674.10892.2.20.10.5Description Defines the CSSD message of the CMC alert

Página 457 - Table 1676. Battery Status

Chassis LED Control Settings UniqueName chassisLEDControlSettingsUniqueObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.25Description Defines the readings

Página 458 - Battery Connection Table

Table 1905. DrsCA2AlertStatusNamedrsCA2AlertStatusObject ID 1.3.6.1.4.1.674.10892.2.21.10.4Description Defines the status of the alert.Syntax DellStat

Página 459 - Tape Drive Table

Table 1910. DRsAlertCurrentStatusNamedrsAlertCurrentStatusObject ID 1.3.6.1.4.1.674.10892.2.5000.10.4Description Current status of object causing the

Página 461

26SNMP TrapsSNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on. Management

Página 462 - Logical Devices Group

Table 1914. Table Index OIDVariable Name alertTableIndexOIDObject ID 1.3.6.1.4.1.674.10892.1.5000.10.2Description Specifies the object identifier fo

Página 463 - Table 1699. Virtual Disk Name

Syntax DisplayStringTable 1920. System FQDNVariable Name alertSystemFQDNObject ID 1.3.6.1.4.1.674.10892.4.5000.10.8Description Specifies fully qual

Página 464

Description Line Item ExplanationChassis intrusion state: <Intrusion state>Specifies the chassis intrusion state (open or closed), for example:C

Página 465

Description Line Item ExplanationPossible memory module event cause: <list of causes>Specifies a list of possible causes for the memory module e

Página 466

RAC TrapsThis section describes the traps that are generated by the SNMP agent of the Remote Access Controller (RAC). All of the enterprise-specific t

Página 467

TrapID Name Description Severity Category Cause Supported by RAC Platform1017 alertDrscSEL 80 percentFullThe RAC system event log is 80% fullMajor Sta

Página 468

Chassis Lock PresentName chassisLockPresentObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.30Description Specifies whether a chassis lock is present on t

Página 469 - Virtual Disk Partition

drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag and drsGlobalCurrStatus. The trap variables are defined in the Dell

Página 470

Table 1929. CMC TrapsTrapID Description Category SubCategory Severityalert2CMCWarning2546 Chassis Management Controller detected a warning.Status Even

Página 471 - Fluid Cache Table

Table 1933. Link Status TrapsTrapID Description Category SubCategory Severityalert2LinkStatusInformation2251 Link status information. Status Events Li

Página 472 - Table 1736. Fluid Cache Name

Table 1937. Security Event TrapsTrapID Description Category SubCategory Severityalert2SecurityInformation2387 Security information. Status Events Secu

Página 473

Table 1941. Voltage Probe TrapsTrapID Description Category SubCategory Severityalert2VoltageProbeNormal2171 Voltage sensor reading is within range.Sta

Página 474

TrapID Description Category Subcategory Severityalert2StorageEnclosureWarning4338 Storage enclosure warning. Error Events Enclosure Minoralert2Storage

Página 475 - Fluid Cache Disk

Table 1948. Storage Management Status TrapsTrapID Description Category Subcategory Severityalert2StorageManagementInformation4179 Storage Management i

Página 476

TrapID Description Category Subcategory Severity4353 Storage Virtual disk failure. Error Events Virtual Disk CriticalAudit TrapsThe Audit Trap group c

Página 477 - Fluid Cache Pool Table

Table 1954. Configuration IO Virtualization TrapsTrapID Description Category SubCategory Severityalert2IOVConfigurationInformation10747 IO virtualizat

Página 478

TrapID Description Severity131328 Under-Voltage Warning (Lower Non Critical - going low)Warning131456 Under-Voltage Warning Cleared Information131330

Página 479

Chassis Watchdog Control Expiry Time Capabilities UniqueName chassiswatchDogControlExpiryTimeCapabilitiesUniqueObject ID 1.3.6.1.4.1.674.10892.1.300.

Página 480

TrapID Description Severity487297 CPU Thermal Trip (Over Temperature Shutdown) ClearedInformation487168 CPU Internal Error Critical 487296 CPU Interna

Página 481 - Table 1782. Message ID Event

TrapID Description Severity1076996 System Event Log (SEL) Full (Logging Disabled)Critical2322176 ASR (Automatic System Recovery) Timer ExpiredCritical

Página 483

27Storage Management Alert ReferenceStorage Management’s alert or event management features let you monitor the health of storage resources such as co

Página 484

Table 1956. Storage Management Alert SeverityAlert Severity Component Status OK/Normal/Informational No action is required. The alert is provided for

Página 485 - Change Management Group

Trap VariablesThe Storage Management SNMP traps use a set of variables that are included with every trap. Below mentioned variables are the Traditiona

Página 486 - Device Group Table

Syntax DisplayStringAccess Read-onlyTable 1962. Object Nexus EventNameobjectNexusEventObject ID 1.3.6.1.4.1.674.10893.1.20.200.6Description Durable, u

Página 487 - Application Group

Description Hostname of object causing the alert if applicable.Syntax DisplayStringAccess Read-onlyTable 1967. Enhanced Service Tag EventNameserviceTa

Página 489 - Operating System Group

28iDRAC7 MIBThe Integrated Dell Remote Access Controller (iDRAC) MIB (filename iDRAC-SMIv1.mib/ iDRAC-SMIv2.mib) is the MIB supported by the Integrate

Página 490

Syntax DellPowerButtonControlSettings (See Power Button Control Settings)Access Read-writeChassis Reseller NameName chassisResellerNameObject ID 1.

Página 491 - Product Information

SNMP Operations Supported SNMP versionGET, GETNEXT, GETBULK SNMP v1 , v2c and v3TRAP SNMP v1 and SNMP v2cNOTE: iDRAC7 does not support the SNMP SET o

Página 492 - Table 1816. DRsProductURL

Description This attribute defines the product name of a remote access card.Syntax StringTypeAccess Read-onlyTable 1970. RAC NameNameracShortNameObjec

Página 493

Table 1975. RAC TypeNameracTypeObject ID 1.3.6.1.4.1.674.10892.5.1.1.7.0Description This attribute defines the type of a remote access card.Syntax Rac

Página 494

Description This attribute defines the service tag of the system.Syntax StringTypeAccess Read-onlyTable 1980. System Express Service CodeNamesystemExp

Página 495

Table 1985. System Data Center NameNamesystemDataCenterNameObject ID 1.3.6.1.4.1.674.10892.5.1.3.8.0Description This attribute defines the Data Center

Página 496 - Table 1838. DRsRedCurrStatus

Description This attribute defines the system ID of the system.Syntax Unsigned16BitRangeAccess Read-onlyTable 1991. System OS VersionNamesystemOSVersi

Página 497 - Table 1843. DRsCMCCurrStatus

Table 1995. Global System StatusNameglobalSystemStatusObject ID 1.3.6.1.4.1.674.10892.5.2.1.0Description This attribute defines the overall rollup sta

Página 498 - Table 1849. DRsKVMPrevStatus

NOTE: See the iDRAC7 MIB file for details of the tables supported under the Storage Details Group.iDRAC7 TrapsThe iDRAC7 generates events that result

Página 499 - Table 1854. DRsTempPrevStatus

Syntax StringTypeTable 2001. Alert Current StatusVariable NamealertCurrentStatusObject ID 1.3.6.1.4.1.674.10892.5.3.1.3.0Description Current status of

Página 500

the last one. Any double quotes found within a message argument string are preprocessed and changed to single quotes.Syntax StringTypeTable 2007. Aler

Página 501 - Chassis Power

Access Read-onlyChassis NMI Button Control Settings UniqueName chassisNMIButtonControlSettingsUniqueObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.45Des

Página 502 - CMC Power Information

TrapID Description Category SubCategory SeverityBattery Warning2226 Battery is low. System Health Battery Event MinorBattery Failure2225 Battery has f

Página 503 - Table 1874. DRsKWhCumulative

TrapID Description Category SubCategory SeverityFiber Channel Warning2538 Fiber Channel warning. System Health Fiber Channel MinorFiber Channel Failur

Página 504 - Table 1880. DRsWattsResetTime

TrapID Description Category SubCategory Severity2089 Network failure or critical event. System Health NIC Config CriticalTable 2018. Operation System

Página 505 - CMC PSU Information

Table 2021. BIOS POST TrapTrapID Description Category SubCategory SeverityBios Post Failure2425 System BIOS detected a failure. System Health BIOS POS

Página 506 - Chassis Servers

Table 2025. Redundancy TrapsTrapID Description Category SubCategory SeverityRedundancy Information2475 Redundancy information. System Health Redundanc

Página 507 - CMC Server Information

TrapID Description Category SubCategory Severity2489 Integrated Dual SD Module redundancy is lost.System Health IDSDM RedundancyCriticalTable 2029. Se

Página 508 - Chassis Alert

TrapID Description Category SubCategory Severitylevel for a long enough period of time to be considered in a warning state.Temperature Statistics Fail

Página 509 - Chassis Alert 2

Storage Trap GroupThe Storage Trap Group contains traps that fall under the Storage event category of iDRAC7. Storage traps are traps generated in res

Página 510 - Legacy Alerting

TrapID Description Category SubCategory Severity4202 Fan warning. Storage Fan Event MinorStorage Fan Failure4201 Fan failure. Storage Fan Event Critic

Página 511 - Table 1912. DRsAlertData

Table 2043. Temperature Probe TrapsTrapID Description Category SubCategory SeverityStorage Temperature Probe Information4211 Temperature probe informa

Página 512

Access Read-onlyUUID TableThese objects comprise the server administrator definitions for the Universal Unique Identifier (UUID).Table 92. UUID Table

Página 513

Table 2046. iDRAC IP Address Change TrapTrapID Description Category SubCategory SeverityiDRAC IP Address Change8499 iDRAC IP address has changed. Audi

Página 514

29Standard Data Type DefinitionsThis appendix contains definitions for data types that are standard in most contexts across the information technology

Página 515 - Table 1923. Trap Description

unknownCapabilities(1)The object’s capabilities are unknown.enableCapable(2)The object can be disabled (offline, a binary 0 value) or enabled (online,

Página 516

ok(3)The object’s status is OK.nonCritical(4)The object’s status is warning, noncritical.critical(5)The object’s status is critical (failure).nonRecov

Página 517 - Understanding Trap Severity

The DellDate definition is required because SNMP V1 does not support 64-bit ranges. The information sent back by this subagent has the most significan

Página 518 - RAC Traps

30SNMP Sample OutputThis appendix contains the sample output from the Simple Network Management Protocol (SNMP) covering the first four groups of the

Página 519 - PowerEdge VRTX CMC Traps

'\02\02\02\02\02\02'1.3.6.1.4.1.674.10892.1.200.10.1.24.1 = 31.3.6.1.4.1.674.10892.1.200.10.1.25.1 ='\03\03\03\03\03\03'1.3.6.1.4.

Página 520 - System Trap Group

1.3.6.1.4.1.674.10892.1.300.40.1.2.1.1 = 11.3.6.1.4.1.674.10892.1.300.40.1.3.1.1 = 81.3.6.1.4.1.674.10892.1.300.40.1.4.1.1 = 21.3.6.1.4.1.674.10892.1.

Página 521 - Table 1930. Fan Traps

Table 96. UUID TypeName uUIDTypeObject ID 1.3.6.1.4.1.674.10892.1.300.20.1.3Description Defines the type of the UUID for this chassis.Syntax DellUU

Página 522 - Table 1936. Redundancy Traps

Table 100. POST Log Chassis IndexName postLogchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.300.30.1.1Description Defines the index (one-based) of th

Página 523

Table 105. POST Log FormatName postLogFormatObject ID 1.3.6.1.4.1.674.10892.1.300.30.1.5Description Defines format of the POST log.Syntax DellLogFo

Página 524 - Storage Trap Group

14 Slot Group...253System

Página 525 - Table 1945. Storage Fan Traps

Description Defines the record index of the event log.Syntax DellUnsigned32BitRangeAccess Read-onlyTable 110. Event Log State Capabilities UniqueNa

Página 526

Description Defines the severity of the event log record.Syntax DellStatusAccess Read-onlyStatus MandatoryTable 115. Event Log Date NameName event

Página 527 - Configuration Traps

Description Defines the index (one-based) of this chassis.Syntax DellObjectRangeAccess Read-onlyTable 119. System BIOS IndexName systemBIOSIndexObj

Página 528 - BMC Traps

Description Defines the image size of the system BIOS in kilobytes (KB). A zero (0) indicates that the image size of the BIOS is unknown.Syntax Dell

Página 529

Table 128. System BIOS Manufacturer NameNamesystemBIOSManufacturerNameObject ID 1.3.6.1.4.1.674.10892.1.300.50.1.11Description Defines the system BIOS

Página 530

Bit 19 EDD (Enhanced Disk Drive) Specification is supportedBit 20 Int 13h - Japanese Floppy for NEC 9800 1.2mb (3.5 in, 1k Bytes/Sector, 360 RPM) is s

Página 531

Bit 1 USB Legacy is supportedBit 2 AGP is supportedBit 3 I2O boot is supportedBit 4 LS-120 boot is supportedBit 5 ATAPI ZIP Drive boot is supportedBit

Página 532

Description Defines the Firmware Table entrySyntax FirmwareTableEntryAccess Not accessibleIndexfirmwarechassisIndex,firmwareIndexTable 134. Firmware C

Página 533 - Alert Severity Levels

Description Defines the status of the firmware.Syntax DellStateSettingsAccess Read-onlyTable 139. Firmware SizeNamefirmwareSizeObject ID 1.3.6.1.4.1.6

Página 534 - SNMP Trap Definitions

Access Read-onlyTable 144. Firmware Version NameNamefirmwareVersionNameObject ID 1.3.6.1.4.1.674.10892.1.300.60.1.11Description Defines the version na

Página 535 - Trap Variables

COO Options Table...

Página 536

Table 148. Intrusion IndexNameintrusionIndexObject ID 1.3.6.1.4.1.674.10892.1.300.70.1.2Description Defines the index of the intrusion objects in this

Página 537 - Viewing SNMP Traps

Description Defines the type of the intrusion object.Syntax DellIntrusionTypeAccess Read-onlyTable 154. Intrusion Location NameNameintrusionLocationNa

Página 538

Table 158. Baseboard IndexNamebaseBoardIndexObject ID 1.3.6.1.4.1.674.10892.1.300.80.1.2Description Defines the index (one-based) of the base board.Sy

Página 539 - Supported Systems

Description Defines the type of the baseboard.Syntax DellBaseBoardTypeAccess Read-onlyTable 164. Baseboard Type NameNamebaseBoardTypeNameObject ID 1.3

Página 540 - RAC Information Group

Table 169. Baseboard Service Tag NameNamebaseBoardServiceTagNameObject ID 1.3.6.1.4.1.674.10892.1.300.80.1.13Description Defines the baseboard service

Página 541 - Table 1974. RAC URL

Table 174. Chassis TypeVariable Name : DellChassisTypeData Type: IntegerPossible Data Values Meaning of Data Valueother(1)The chassis type is not one

Página 542 - System Information Group

Possible Data Values Meaning of Data Valueunknown(2)The status of the chassis connection is unknown.ok(3)The status of the chassis connection is OK.fa

Página 543 - Table 1981. System Asset Tag

Possible Data Values Meaning of Data Valuenone(0)The hard drive has no fault LED capabilities.unknownCapabilities(1)The hard-drive fault LED capabilit

Página 544

NOTE: Chassis identification capabilities allow system administrators to set front panel light-emitting diodes (LEDs) to blink when the chassis has ma

Página 545 - Status Group

manualRebootWithoutOSShut downCapable(32)The operator can reboot without operating system shutdown.manualPowerOffWithOSShutd ownCapable(64)The operato

Página 546 - Storage Details Group

Power Supply Connection Table...444Te

Página 547

automaticNotificationCapable(4)Watchdog controls can be set to notify capable hostautomaticWatchDogTimerCapable(8)Watchdog controls can be set to func

Página 548

enableCapable(2)The power button can be enabled (online) or disabled (offline).Table 189. Power Button Control SettingsVariable Name : DellPowerButton

Página 549

Table 193. Baseboard TypeVariable Name : DellBaseBoardTypeData Type: IntegerPossible Data Values Meaning of Data Valueunknown(1)The baseboard type is

Página 550 - Table 2013. Fan Traps

Data Type: IntegerPossible Data Values Meaning of Data Valueother(1)The firmware type is other than following values.unknown(2)The firmware type is un

Página 551 - Table 2017. NIC Traps

boardIsHostingBoard(1)This baseboard is a hosting board.boardRequiresDaughterBoard (2)This baseboard requires at least one daughter board or auxiliary

Página 552 - Table 2019. PCI Device Traps

6Operating System GroupThe Operating System Group provides status and identifying information about a system’s operating system. Identifying informati

Página 553 - Table 2024. Power Usage Traps

Access Read-onlyTable 201. Operating System Memory State SettingsName operatingSystemMemoryStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.400.20.1.3

Página 554 - Table 2025. Redundancy Traps

Table 206. Operating System Memory Available Page File SizeName operatingSystemMemoryAvailablePageFileSizeObject ID 1.3.6.1.4.1.674.10892.1.400.20.1.

Página 556

7System Resource GroupThe Management Information Base (MIB) variables presented in this section enable you to track various attributes of your system

Página 557

RAC Traps...

Página 558

Table 211. System Resource Map Chassis IndexName systemResourceMapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.1Description Defines the i

Página 559 - Audit Trap Group

Description Defines the type of this system map.Syntax DellSystemResourceMapType (System Resource Map Type)Access Read-onlySystem Resource Owner Ta

Página 560 - Configuration Trap Group

Table 221. System Resource Owner State CapabilitiesName systemResourceOwnerStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.500.20.1.3Description

Página 561 - Capabilities Unique

Description Defines the description name of the system resource owner.Syntax DellStringAccess Read-onlyTable 227. System Resource Owner Interface I

Página 562 - Dell Status Data Types

Table 231. System Resource I/O Port IndexName systemResourceIOPortIndexObject ID 1.3.6.1.4.1.674.10892.1.500.30.1.2Description Defines the index (on

Página 563 - Dell Date

Description Defines the share disposition of the system resource I/O port.Syntax DellResourceShareDisposition (Resource Share Disposition)Access Re

Página 564 - Full Dates

Table 241. System Resource Memory Chassis IndexName systemResourceMemorychassisIndexObject ID 1.3.6.1.4.1.674.10892.1.500.40.1.1Description Defines

Página 565 - SNMP Sample Output

Syntax DellObjectRangeAccess Read-onlyTable 246. System Resource Memory Share DispositionName systemResourceMemoryShareDispositionObject ID 1.3.6.1

Página 566

Access Not accessibleTable 251. System Resource Interrupt Table EntryName systemResourceInterruptTableEntryObject ID 1.3.6.1.4.1.674.10892.1.500.50.

Página 567

Access Read-writeTable 256. System Resource Interrupt StatusName systemResourceInterruptStatusObject ID 1.3.6.1.4.1.674.10892.1.500.50.1.5Descriptio

Comentários a estes Manuais