20 Deployment Guide
Figure 1-3. Cabling the SAS Cluster and PowerVault MD3000
Table 1-5. SAS Cluster Hardware Interconnections
Cluster Component Connections
PowerEdge system node One CAT 5e/6 cable from public NIC to the local
area network (LAN)
One CAT 5e/6 cable from private Gigabit NIC to
Gigabit Ethernet switch (private network)
One CAT 5e/6 cable from redundant private Gigabit
NIC to redundant Gigabit Ethernet switch (private
network)
Two SAS connections to a PowerVault MD3000
storage system node using a SAS 5/E. See "Cabling
Your SAS Storage System" on page 20
Dell PowerVault MD3000 Two CAT 5e/6 cables connected to a LAN (one from
each storage processor module)
Two SAS connections to each PowerEdge system
node using a SAS 5/E controller. See "Cabling Your
SAS Storage System" on page 20
Gigabit Ethernet switch One Cat 5e/6 connection to the private Gigabit NIC
on each PowerEdge system
One Cat 5e/6 connection to the other Gigabit
Ethernet switch
Private Network
PowerEdge Systems
PowerVault MD3000
Storage System