Example to Prepares physical disk 3 on connector 0 of
controller 1 for removal. On a SAS controller, the
physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA controllers
omconfig storage pdisk action=remove
controller=1 pdisk=0:3
Example for SAS controllers
omconfig storage pdisk action=remove
controller=1 pdisk=0:2:3
Omconfig Instant Erase Secured Physical Disk
Description Erases the given encrypted disk.
NOTE: This command is applicable only on
Micron devices.
Syntax
omconfig storage pdisk
action=instantsecureerase controller=id
pdisk=<PDISKID>, where id is the controller ID.
The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport
storage controller to display the controller IDs
and then type omreport storage pdisk
controller=ID to display the IDs for the
physical disks attached to the controller.
Example to Erase physical disk 3 on connector 0 of controller
1. On a SAS controller, the physical disk resides in
enclosure 2.
Example for SCSI, SATA, and ATA controllers
omconfig storage pdisk
action=instantsecureerase controller=1
pdisk=0:3
Example for SAS controllers
omconfig storage pdisk
action=instantsecureerase controller=1
pdisk=0:2:3
Omconfig Cryptographic Erase Secured Physical Disk
Description Erases the given encrypted disk.
NOTE: This command is applicable only on
Non-Volatile Memory Express (NVMe) devices.
Syntax
omconfig storage pdisk
action=cryptographicerase controller=id
pdisk=<PDISKID>, where id is the controller ID.
The <PDISKID> variable specifies the physical disk.
NOTE: To obtain these values, type omreport
storage controller to display the controller IDs
and then type omreport storage pdisk
controller=ID to display the IDs for the
physical disks attached to the controller.
Example to Erase physical disk 3 on connector 0 of controller
1. On a SAS controller, the physical disk resides in
enclosure 2.
146