Dell OpenManage Server Administrator Version 6.2 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Placa-mãe para servidores/estações de trabalho Dell OpenManage Server Administrator Version 6.2. Dell OpenManage Server Administrator Version 6.2 User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Dell™OpenManage™ServerAdministratorStorageManagementUser's
Guide
Notes and Cautions
Information in this document is subject to change without notice.
©2009 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, PowerVault, and Dell OpenManage are trademarks of Dell Inc.; Microsoft, Windows are registered trademarks and Windows Server is
a trademark of Microsoft Corporation in the United States and other countries; VMware is a registered trademark of VMware Inc.
Server Administrator includes software developed by the Apache Software Foundation (www.apache.org). Server Administrator utilizes the OverLIB JavaScript library. This library can
be obtained from www.bosrup.com.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any
proprietary interest in trademarks and trade names other than its own.
August 2009
Overview
Virtual Disks
Getting Started
Physical Disks
Understanding RAID Concepts
Protecting Your Virtual Disk with a Hot Spare
Quick Access to Storage Status and Tasks
Moving Physical and Virtual Disks from One System to Another
Storage Information and Global Tasks
BIOS Terminology
Setting Hot Spare Protection Policy
Troubleshooting
Controllers
Frequently Asked Questions
RAID Controller Batteries
Supported Features
Connectors
Determining the Health Status for Storage Components
Enclosures and Backplanes
NOTE: A NOTE indicates important information that helps you make better use of your computer.
CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed.
Vista de página 0
1 2 3 4 5 6 ... 154 155

Resumo do Conteúdo

Página 1 - Notes and Cautions

Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide  Notes and Cautions Information in this document is subject to change

Página 2 -  Supported Features

 Battery Tasks Table A-20. Battery Tasks Supported on the PERC 5/E, PERC 5/i, PERC 6/E, PERC 6/I, PERC 6/I, PERC 6/I Modular, and CERC 6/I Controll

Página 3

Enclosure Temperature 1 Enclosure's EMM Firmware Version 1 Enclosures 1 Event Log viewing entries 1 Export Log 1 F Fan Properties 1 FAQs

Página 4

omconfig Global Commands 1 omconfig Physical Disk Commands 1 omconfig Virtual Disk Commands 1 Online and Offline 1 P Parity 1 PERC 2/SC, 2/DC, 3

Página 5

Rescan Connector 1 Rescan Controller 1 Resolving Windows 2000 Upgrade Problems 1 Revertible Hot Spare 1 S S.M.A.R.T alerts 1 Set Asset Data 1 S

Página 6 - SATA1.5/6ch Controllers

Unmirror 1 Updating disk information 1 Upgrading from Windows NT 1 User Privileges 1 Using the Command Line Interface 1 Using the Graphical User

Página 7

Back to Contents Page Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide Information in this document is subject to change

Página 8

Back to Contents Page  Overview Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide What's New in this Release? 

Página 9

Compatibility With Linux Utilities Installing Storage Management on a Linux system that has RAID storage management utilities provided by Dell or oth

Página 10 - Physical Disk Tasks

 Supported Non-RAID Controllers Storage Management supports the following non-RAID controllers. l Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, LSI 1020,

Página 11 - Virtual Disk Specifications

Back to Contents Page  Quick Access to Storage Status and Tasks Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide This

Página 12 - Supported RAID Levels

Storage Properties and Current Activity The Configuration/Information subtab displays information regarding a storage component. These properties in

Página 13 - Controller Tasks

 Virtual Disk Tasks Table A-23. Virtual Disk Tasks Supported by the PERC 5/E, PERC 5/i, PERC 6/E, PERC 6/I, PERC 6/I Modular, and CERC 6/I Controll

Página 14

l "SMART Thermal Shutdown" l "Set Temperature Probe Values" Rescan to Update Storage Configuration Changes The Rescan task s

Página 15

Back to Contents Page  Storage Information and Global Tasks Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide Storage

Página 16

 Enable/Disable Smart Thermal Shutdown By default, the operating system and server shut down when the PowerVault™ 220S and PowerVault 221S enclosure

Página 17

 Storage Components For information on attached controllers, see the following topics: l "Controller Properties and Tasks" l "Con

Página 18

Back to Contents Page  Understanding RAID Concepts Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide What Is RAID? 

Página 19

RAID provides different methods or RAID levels for organizing the disk storage. Some RAID levels maintain redundant data so that you can restore data

Página 20

l Concatenates n disks as one large virtual disk with a capacity of n disks. l Data fills up the first disk before it is written to the second di

Página 21

l "Organizing Data Storage for Availability and Performance" l "Comparing RAID Level and Concatenation Performance" l "C

Página 22

 RAID 5 Characteristics: l Groups n disks as one large virtual disk with a capacity of (n-1) disks. l Redundant information (parity) is alterna

Página 23

l Groups n disks as one large virtual disk with a capacity of (n-2) disks. l Redundant information (parity) is alternately stored on all disks. l

Página 24

 Supported RAID Levels Table A-25. RAID Levels Supported by the PERC 5/E, PERC 5/i, PERC 6/E, PERC 6/I, PERC 6/I Modular, and CERC 6/I Controllers

Página 25

See the following: l "Organizing Data Storage for Availability and Performance" l "Comparing RAID Level and Concatenation Performan

Página 26 - Permanently Degraded

RAID 10, data is striped across multiple physical disks. The striped disk group is then mirrored onto another set of physical disks. RAID 10 can be co

Página 27 - Rebuilding

 Related Information: See the following: l "Organizing Data Storage for Availability and Performance" l "Comparing RAID Level a

Página 28

No-RAID In Storage Management, a virtual disk of unknown metadata is considered a No- RAID volume. Storage Management does not support this type of

Página 29

Back to Contents Page  Troubleshooting Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide Common Troubleshooting Proced

Página 30

On SCSI controllers, use the Rescan controller task to update information for the controller and attached devices. This operation may take a few minut

Página 31 -  Physical Disks

 Does my controller support this feature? See "Supported Features" If you do not have a suitable backup available, and if the failed disk

Página 32 - Other Disk Procedures

l "Cannot Create a Virtual Disk" l "Virtual Disk Errors on Linux" l "Problems Associated With Using the Same Physical Di

Página 33

l Is there adequate available space on the disk? The physical disks that you have selected for creating the virtual disk must have an adequate amoun

Página 34

l "Physical Disk is Offline or Displays an Error Status" l "A Disk is Marked as Failed When Rebuilding in a Cluster Configuration&qu

Página 35 - Prepare to Remove

 Enclosure Support Table A-27. Enclosure Support on the PERC 5/E, PERC 5/i, PERC 6/E, PERC 6/I, PERC 6/I, Modular, and CERC 6/I Controllers Suppo

Página 36 - Cancel Rebuild

l Rebuild l Virtual disk format l I/O If you receive an alerts 2146 through 2150 as the result of doing a rebuild or while the virtual disk

Página 37 - Online and Offline

Storage Management May Delay Before Updating Temperature Probe Status In order to display the enclosure temperature and temperature probe status, Sto

Página 38 - Instant Secure Erase

Back to Contents Page  Virtual Disks Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide  In order to implement RAID fun

Página 39

specified physical disks. Depending on the size of the virtual disk, the virtual disk may not consume all of the space on the physical disks. Any left

Página 40 -  RAID Controller Batteries

Number of Physical Disks per Virtual Disk There are limitations on the number of physical disks that can be included in the virtual disk. These limit

Página 41

disks and the controller connector to be used. You need a good knowledge of RAID levels and hardware to use the Advanced Wizard. See "Create Virt

Página 42

 Exceptions for Reconfiguring a Concatenated Virtual Disk on PERC 3/Si, 3/Di, CERC SATA1.5/6ch, and CERC SATA1.5/2s Controllers You can create a con

Página 43 - Battery Delay Learn Cycle

 What is a Virtual Disk Bad Block? Virtual disk bad blocks are due to bad blocks on one or more member physical disks. Read operation on the virtual

Página 44 -  BIOS Terminology

Use this window to view information about the virtual disks and execute virtual disk tasks.  Virtual Disk Properties The virtual disk properties ca

Página 45 -  Connectors

 Virtual Disk Tasks Do the following to execute a virtual disk drop-down menu task:  1. Expand the Storage tree object to display the controller o

Página 46 - Connector Health

 Battery Tasks Table A-29.BatteryTasksSupportedonthePERCH800,PERCH700Adapter,PERCH700Integrated,andPERCH700ModularControllers  C

Página 47 - Connector Properties

l "Change Policy" l "Replace Member Disk" l "Clear Virtual Disk Bad Blocks" l "Secure Virtual Disk" 

Página 48 - Path Health

Use the Delete task to destroy all data on the virtual disk. See "Virtual Disk Task: Delete" for more information.  Assign and Unassign De

Página 49 - Related Tasks

Rename  Does my controller support this feature? See "Supported Features." Use the Rename task to change the virtual disk's name. Se

Página 50 -  Controllers

your RAID and size selection. Before creating a virtual disk, you should be familiar with the information in "Considerations Before Creating Vir

Página 51 - RAID Controller Features

 Does my controller support this feature? See "Supported Features." This screen displays the virtual disk attributes and enables you to as

Página 52 - Cache Policy

¡ Intelligent Mirroring — Automatically calculates the span composition based on the physical disks you select. Spans are not displayed on this scr

Página 53 - Disk Cache Policy

Depending on the RAID level you selected and the virtual disk size, this screen displays the disks and connectors (channels or ports) available for co

Página 54 - Non-RAID SCSI Controllers

 2. The Size text box displays the default size of the virtual disk, depending upon the RAID configuration you selected. You can specify a different

Página 55 - Controller Health

Click Continue to return to "Create Virtual Disk Advanced Wizard (Step 4 of 4)." Virtual Disk Task: Reconfigure (Step 1 of 3)  Does my co

Página 56 - Controller Properties

¡ Select RAID 0 for striping. This selection groups n disks together as one large virtual disk with a total capacity of n disks. Data is stored to th

Página 57

 Virtual Disk Specifications Table A-33. Virtual Disk Specifications for the PERC H800, PERC H700 Adapter, PERC H700 Integrated, and PERC H700 Modul

Página 58

Other controllers have a Fast Initialize and Slow Initialize task available on the controller task drop-down menu. See "Considerations for Fast I

Página 59

 2. Expand a controller object.  3. Select the Virtual Disks object.  4. Depending on the task you want to initiate, select one of the foll

Página 60 - Set Rebuild Rate

l The virtual disk name can contain only alphanumeric characters as well as spaces, dashes and underscores. The maximum name length depends on the co

Página 61 - Export Log

 To Split a Mirror: Click Split Mirror. If you want to exit without splitting the mirror, click Go Back To Virtual Disk Page.   To locate this ta

Página 62

 2. Expand a controller object.  3. Select the Virtual Disks object.  4. Select Unmirror from the Available Tasks drop-down menu.  5. Cl

Página 63

You can copy data from a physical disk, which is a member of a virtual disk, to another physical disk by providing a Replace Member Configuration opti

Página 64

Supported RAID Levels Table A-34. RAID Levels Supported by the PERC H800, PERC H700 Adapter, PERC H700 Integrated, and PERC H700 Modular Controllers

Página 65

l "Read, Write, Cache and Disk Cache Policy" l "Enclosure Support" For enclosure-supported tasks, see "Enclosure and Back

Página 66

 Virtual Disk Tasks Table A-41.VirtualDiskTasksSupportedbytheSAS5/iR,SAS6/iR,andH200Controllers  Supported RAID Levels Table A-42

Página 67 - Set Check Consistency Rate

 Virtual Disk Specifications Table A-43.VirtualDiskSpecificationsfortheSAS5/iR,SAS6/iR,andPERCH200Controllers  Read, Write, Cache an

Página 68 - Set Reconstruct Rate

Back to Contents Page  Supported Features Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide Different controllers suppo

Página 69

 Enclosure Support Table A-45. Enclosure Support on the SAS 5/iR, SAS 6/iR, and H200 Controllers Supported Features on the PERC S100 and S300 Con

Página 70 - Set Patrol Read Mode

 Virtual Disk Specifications Table A-49. Virtual Disk Specifications for the PERC S100 and S300 Controllers  Supported RAID Levels Table A-50. RA

Página 71 - Start and Stop Patrol Read

 Enclosure Support Table A-52. Enclosure Support on the PERC S100 and S300 Controllers Supported Features on the Non-RAID Controllers This sectio

Página 72 - Manage Preserved Cache

Battery Tasks Table A-54. Battery Tasks Supported on the Non-RAIDControllers  Connector Tasks Table A-55. Connector Tasks Supported on the Non-

Página 73 - Manage Security Key

 Enclosure Support Table A-58. Enclosure Support on the Non-RAIDControllers Enclosure and Backplane Features This section identifies the featur

Página 74

 Enclosure and Backplane Support for Smart Thermal Shutdown Table A-61.EnclosureSupportforSmartThermalShutdown Set Asset Data (includes asse

Página 75 -  Enclosures and Backplanes

Back to Contents Page  Determining the Health Status for Storage Components Dell™OpenManage™ServerAdministratorStorageManagementUser'sG

Página 76 - SMART Thermal Shutdown

Included) Health Status Rollup: All Physical Disks in a Virtual Disk are in Foreign State Table B-4. Health Status Rollup: All Physical Disks in a

Página 77 - Enclosure Management

Table B-7. Health Status Rollup: Virtual Disk is Failed (Enclosures Not Included) Health Status Rollup: Unsupported Firmware Version Table B-8. H

Página 78

Health Status Rollup: One Enclosure Temperature Probe is Failed Table B-12. Health Status Rollup: One Enclosure Temperature Probe is Failed Health

Página 79 - Enclosure Tasks

 Battery Tasks Table A-2. Battery Tasks Supported by the PERC 3/SC, 3/DC, 3/QC, 4/SC, 4/DC, 4/Di, 4e/Si, 4e/Di, 4e/DC, CERC ATA100/4ch, and 4/IM Co

Página 80

Health Status Rollup: Physical Disk is Rebuilding Table B-15. Health Status Rollup: Physical Disk is Rebuilding Back to Contents Page     Stora

Página 81 - Set Asset Data

Back to Contents Page  Physical Disks Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide Physical disks reside within an

Página 82 - EMM Properties

SMART alerts are messages predicting that a disk may fail in the near future. If a physical disk is receiving SMART alerts, you should replace the dis

Página 83 - Power Supply Properties

Status These icons represent the severity or health of the storage component.  Normal/OK  Warning/Non-critical  Critical/Fatal See "

Página 84

 Physical Disk Tasks Do the following to execute a physical disk task:  1. Expand the Storage tree object to display the controller objects. 

Página 85

 7. Select a task from the Available Tasks drop-down menu.  8. Click Execute.  Physical Disk Drop-down Menu Tasks: l "Blink and Unblin

Página 86

l Wait until you notice the initial blink pattern has changed into a different pattern or the lights have stopped blinking. A physical disk is no

Página 87 - Related information:

 You should be familiar with the size requirements and other considerations associated with hot spares. See the following sections for more informati

Página 88 -  Getting Started

 To clear the physical disk:  1. Review the physical disk that will be erased by the clear task. Be sure that it does not contain necessary data an

Página 89 - Common Storage Tasks

l Unconfigured SED drive l Foreign configured secured drives l Unconfigured and foreign SED drive even when Security Key is not present in the co

Página 90

4/IMControllers  Virtual Disk Specifications Table A-6. Virtual Disk Specifications for the PERC 3/SC, 3/DC, 3/QC, 4/SC, 4/DC, 4/Di, 4e/Si, 4e/Di

Página 91 - 6/I Controllers

Back to Contents Page  RAID Controller Batteries Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide Battery Properties

Página 92 - S300 Controllers

 Battery Tasks Do the following to execute a drop-down menu battery task:  1. Expand the Storage tree object to display the controller objects.

Página 93

Drop-down Menu Battery Tasks: l "Recondition Battery" l "Start Learn Cycle" l "Battery Delay Learn Cycle"  Recon

Página 94

 Battery Delay Learn Cycle  Does my controller support this feature? See "Supported Features." The controller firmware automatically ini

Página 95

Back to Contents Page  BIOS Terminology Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide BIOS Terms and the PERC 3/SC

Página 96 - Required Conditions

Back to Contents Page  Connectors Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide Channel Redundancy and Thermal Shu

Página 97 - Moving the Disks

¡ PERC 3/DC, 3/QC, 4/DC, 4e/DC, 4/Di, and 4e/Di Controllers: It is recommended that you only use RAID 10 or RAID 50. ¡ PERC 3/Di Controller: It is

Página 98

 Connector Information For information on the connector, see the following topics: l "Connectors" l "Connector Properties and Tas

Página 99

Does my controller support this feature? See "Supported Features." On a SCSI controller, this task rescans the controller connectors to ver

Página 100

 Clearing the Redundant Path View If you do not want the redundant path view, physically disconnect the connector port from the enclosure and reboot

Página 101

 Supported RAID Levels Table A-7. RAID Levels Supported by the PERC 3/SC, 3/DC, 3/QC, 4/SC, 4/DC, 4/Di, 4e/Si, 4e/Di, 4e/DC, CERC ATA100/4ch, and 4

Página 102

Back to Contents Page  Controllers Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide This section describes the control

Página 103

The following Cost Effective RAID Controller (CERC) controllers use Advanced Technology Attachment (ATA) technology. l CERC ATA100/4ch l CERC 6/I

Página 104

RAID Controller Read, Write, Cache, and Disk Cache Policy When creating a virtual disk, you specify the read, write, and cache policies for the virt

Página 105 -  Overview

 Does my controller support this feature? See "Supported Features." The Direct I/O and Cache I/O cache policies apply to reads on a specif

Página 106 - Supported Controllers

 This section applies to 3/DC, 4/DC, and 4e/DC controllers If you are using a PERC 3/DC, 4/DC, or 4e/DC controller in a cluster configuration, you m

Página 107 - Supported Enclosures

 Non-RAID SAS Controllers The following non-RAID controllers use Serial Attached SCSI (SAS) technology. l SAS 5/i Integrated l SAS 5/E l SA

Página 108 - Storage Component Severity

 Controller Information For information on the controller, see the following topics: l "Controllers" l "Controller Properties and

Página 109 - Alerts or Events

Failed — The controller has encountered a failure and is no longer functioning. Firmware Version This property displays the version of the firmware

Página 110 - Related Information:

 Controller Tasks Do the following to execute a controller task:  1. Expand the Storage tree object to display the controller objects.  2. Sel

Página 111 - Global Tasks

 Does my controller support this feature? See "Supported Features." On SCSI controllers, a rescan updates configuration changes (such as n

Página 112 - Storage Controllers

Enclosure Support Table A-9. Enclosure Support on the PERC 3/SC, 3/DC, 3/QC, 4/SC, 4/DC, 4/Di, 4e/Si, 4e/Di, 4e/DC, CERC ATA100/4ch, and 4/IM Contro

Página 113 - Storage Components

 Set Rebuild Rate  Does my controller support this feature? See "Supported Features." Use the Set Rebuild Rate task to change the rebuil

Página 114 - What Is RAID?

 To locate this task in Storage Management:  1. Expand the Storage tree object to display the controller objects.  2. Select a controller obje

Página 115 - Concatenation

Depending on the controller, the log file name will be either afa_<mmdd>.log or lsi_<mmdd>.log where <mmdd> is the month and date. F

Página 116 - RAID Level 0 (Striping)

Based on this information, you can decide whether you want to import, recover, or clear the foreign configuration.  To preview the import of foreign

Página 117 - RAID Level 1 (Mirroring)

The Import Foreign Configuration task is only displayed when the controller has detected a foreign configuration. You can also identify whether or not

Página 118 - RAID 6 Characteristics:

configuration). You can identify whether or not a previously used physical disk contains a foreign configuration (virtual disk) by checking the physic

Página 119 - RAID 50 Characteristics:

Name This property displays the name of the physical disk. The name is comprised of the connector number followed by the disk number. Current State T

Página 120 - RAID 60 Characteristics:

 Related Information: l "Foreign Configuration Operations" Set Background Initialization Rate  Does my controller support this featur

Página 121 - RAID 10 Characteristics:

information about the check consistency task. The check consistency rate, configurable between 0% and 100%, represents the percentage of the system r

Página 122

 4. Select Set Reconstruct Rate from the Available Tasks drop-down menu.  5. Click Execute. You can also locate this task from the Change Con

Página 123 - No-RAID

 Connector Tasks Table A-12.ConnectorTasksSupportedbythePERC3/Si,3/Di,CERCSATA1.5/2s,andCERCSATA1.5/6chControllers  Physical Disk T

Página 124 -  Troubleshooting

In this case, the enclosure status is displayed in warning mode. The Enclosures page displays all enclosure components (EMMs, Fans, Physical Disks, Po

Página 125 - Replacing a Failed Disk

reboots while the Patrol Read task is running in Auto mode, the Patrol Read restarts at zero percent (0%). When the Patrol Read task is set to Auto mo

Página 126

Change Controller Properties  Does my controller support this feature? See "Supported Features." The Change Controller Properties task p

Página 127 - A Rebuild Does Not Work

Data in the cache may also be lost in case of unintended cable or power failure. In the event of such a failure, Storage Management preserves the data

Página 128 - Nonredundant Virtual Disks

space.)  3. Read the Passphrase guidelines and acknowledge the note by selecting the accompanying check box. Ensure that you save the Passphrase.

Página 129

Back to Contents Page  Enclosures and Backplanes Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide Physical disks can b

Página 130

Enclosure Power Supplies The enclosure's power supplies are displayed under the Power Supplies object in the tree view. You can select the Power

Página 131

Changing the Mode on PowerVault 220S and PowerVault 221S Enclosures When toggling the bus configuration switch on a PowerVault 220S or PowerVault 22

Página 132 -  Virtual Disks

l "Physical Disks" Enclosure and Backplane Properties and Tasks Use this window to view information about the enclosure or backplane and

Página 133

 Enclosure Tasks Do the following to execute a drop-down menu enclosure task:  1. Expand the Storage tree object to display the controller objects

Página 134 - Creating Virtual Disks

 Virtual Disk Specifications Table A-15.VirtualDiskSpecificationsforthePERC3/Si,3/Di,CERCSATA1.5/2s,andCERCSATA1.5/6chControllers 

Página 135 - Expansion

 Does my enclosure support this feature? See "Supported Features." Use the Blink task to blink the light-emitting diodes (LEDs) on the enc

Página 136 - SATA1.5/2s Controllers

For information related to the enclosure's EMMs, see "Enclosure Management Modules (EMMs)."  Enclosure Components For information on

Página 137 - Recommendations

 1. The enclosure's temperature probes are listed in the Temperature Probes section of the screen. Select the probes that you want to change.

Página 138 - Virtual Disk Properties

Fan Properties Use this window to view information about the enclosure's fans. The fans are a component of the enclosure's cooling module

Página 139

Temperature Probe Properties and Tasks  Does my enclosure support this feature? See "Supported Features." Use this window to view inform

Página 140

Set Temperature Probe Properties and Tasks Click the Set Temperature Probe button to launch the wizard for changing the temperature probe's Warn

Página 141

Back to Contents Page  Frequently Asked Questions Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide Why is a rebuild n

Página 142

What controllers do I have? Each controller attached to the system is displayed under the Storage object in the tree view. In addition, the Storage

Página 143

Back to Contents Page  Getting Started Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide Launching Storage Management

Página 144

User and Power User privileges allow you to view storage status, but not manage or configure storage. With User and Power User privileges, you can use

Página 145

Table A-17.Read,Write,andCachePolicySupportedbythePERC3/Si,3/Di,CERCSATA1.5/2s,andCERCSATA1.5/6chControllers  Enclosure Support 

Página 146 - Physical Disks Selected

l Assign a hot spare to the virtual disk. When a virtual disk uses a redundant RAID level, then you can assign a hot spare (backup physical disk) to

Página 147 - Span Edit

Back to Contents Page  Protecting Your Virtual Disk with a Hot Spare Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide 

Página 148

Dedicated Hot Spare Considerations The following considerations apply to dedicated hot spares: l Considerations for RAID 10 and RAID 50. If you hav

Página 149 - Controllers

already assigned. When a physical disk fails in a redundant virtual disk, the failed disk is rebuilt onto the hot spare. In this case, the controller

Página 150 - Considerations for Format

Back to Contents Page  Setting Hot Spare Protection Policy Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide Dedicated

Página 151 - Virtual Disk Task: Rename

l Enclosure affinity settings for a global/dedicated hot spare are not automatically set when you upgrade to Dell OpenManage version 6.1. l Enclosu

Página 152 - Split Mirror

Back to Contents Page  Moving Physical and Virtual Disks from One System to Another Dell™OpenManage™ServerAdministratorStorageManagementUser&

Página 153 - Unmirror

 Moving the Disks  1. Shut down the system that the physical disks are being moved from.  2. If the receiving controller has a preexisting virt

Página 155

Back to Contents Page Dell™OpenManage™ServerAdministratorStorageManagementUser'sGuide A Alert Messages 1 Assign and Unassign Dedicate

Comentários a estes Manuais

Sem comentários