Dell OpenManage Server Administrator Version 6.2 Guia do Utilizador Página 621

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 760
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 620
Storage Management Group 621
Temperature Probe Maximum Warning
Temperature Probe Maximum Critical
Temperature Probe Current Value
Name temperatureProbeMaxWarning
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.9
Description Identifies the maximum temperature that will force the probe into
a warning state.
Syntax Integer
Access Read-only
Name temperatureProbeMaxCritical
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.10
Description Identifies the maximum temperature that will force the probe into
an error state.
Syntax Integer
Access Read-only
Name temperatureProbeCurValue
Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.11
Description Identifies the current temperature of this probe.
Syntax Integer
Access Read-only
Vista de página 620
1 2 ... 616 617 618 619 620 621 622 623 624 625 626 ... 759 760

Comentários a estes Manuais

Sem comentários