Dell OpenManage Server Administrator Version 5.0 Guia do Utilizador Página 24

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 120
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 23
24 Event Message Reference
1204 Current sensor detected a
failure value
Sensor location: <Location in
chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
If sensor type is not
discrete:
Current sensor value
(in Amps):
<Reading>
If sensor type is discrete:
Discrete current state:
<State>
Error A current sensor on the power supply for the
specified system exceeded its failure threshold.
The sensor location, chassis location,
previous state, and current sensor value are
provided.
1205 Current sensor detected a
non-recoverable value
Sensor location: <Location in
chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
If sensor type is not
discrete:
Current sensor value
(in Amps):
<Reading>
If sensor type is discrete:
Discrete current state:
<State>
Error A current sensor in the specified system
detected an error from which it cannot
recover. The sensor location, chassis location,
previous state, and current sensor value are
provided.
Table 2-5. Current Sensor Messages (continued)
Event ID Description Severity Cause