Dell PowerConnect W-AirWave 7.4 Manual do Utilizador Página 14

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 16
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 13
14 | Virtualization and Scalability Dell PowerConnect W-AirWave 7.4 | Server Sizing Guide
Table 7 Wired Scalability Test Values
Category Value
Ratio of switches/routers to access points 20%
Average port density of switches/routers 36
Read ARP polling period (hours) 8
Read CDP table for device discovery polling period (hours) 8
Read bridge forwarding table polling period (hours) 8
Interface polling period (minutes) 20
Table 8 VisualRF Scalability Test Values
Category Value
Average floor plan size (feet) 62,500
Number of access points per floor plan 20
Number of clients per floor plan 100
Number of attenuation grid cells per floor plan 2,500
Number Rogue devices per floor plan 20
AMP Synchronization timer (minutes) 15
Rogue location timer (minutes) 30
Location calculation timer (min/max/number of samples) 90/360/3
Vista de página 13